• 제목/요약/키워드: Flow Correction Factor

검색결과 76건 처리시간 0.027초

SURGE LINE STRESS DUE TO THERMAL STRATIFICATION

  • Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.239-250
    • /
    • 2008
  • If there is a water flow with a range of temperature inside a pipe, the wanner water tends to float on top of the cooler water because it is lighter, resulting in the upper portion of the pipe being hotter than the lower portion. Under these conditions, such thermal stratification can play an important role in the aging of nuclear power plant piping because of the stress caused by the temperature difference and the cyclic temperature changes. This stress can limit the lifetime of the piping, even leading to penetrating cracks. Investigated in this study is the effect of thermal stratification on the structural integrity of the pressurizer surge line, which is reported to be one of the pipes most severely affected. Finite element models of the surge line are developed using several element types available in a general purpose structural analysis program and stress analyses are performed to determine the response characteristics for the various types of top-to-bottom temperature differentials due to thermal stratification. Fatigue analyses are also performed and an allowable environmental correction factor is suggested.

AC PDP 시스템의 전원회로 해석과 소비전력 분석 (Power system analysis and power consumption breakdown for an ac PDP system)

  • 안재우;하정준;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.446-449
    • /
    • 2001
  • This paper presents the results of the power system analysis and power loss breakdown peformed on a 40-inch ac plasma display panel (PDP) TV set. The architecture and function of power system is reviewed. The power flow inside the PDP TV set is presented, and the distribution of the power loss is analyzed. It was found that the sustain driver circuit and power factor correction (PFC) circuit are the two major sources of the power loss. The results of this paper can be used as a preliminary guideline to improve the architecture and efficiency of power systems for ac PDP application systems.

  • PDF

능동 블리더 회로를 적용한 조광기 호환용 LED 구동회로에 관한 연구 (A Study on LED Driver Compatible with Triac-dimmer Employing Active Bleeder)

  • 염봉호;홍성수;김택우
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.297-302
    • /
    • 2014
  • In this paper, a LED driver compatible with TRIAC-dimmer applying active bleeder is proposed. If TRIAC-dimmer is connected with LED driver, flicker phenomenon occurs by TRIAC malfunction. In order to prevent this problem, a current over holding current must flow into TRIAC. Therefore, additional circuit compatible with TRIAC-dimmer is required to provide enough current. Passive bleeder has power loss in whole operation period. The proposed circuit apply a valley-fill circuit for power-factor-correction and a novel active bleeder detecting malfunction point of TRIAC. Therefore, it prevent malfunction of TRIAC-dimmer and have advantage of higher efficiency than passive bleeder. To verify the validity of proposed circuit, 13W-lighting LED driver prototype has been proposed.

Measurement of Thermal Conductivity of Foods in Liquid and Solid Phase Using a Thermal Probe

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.334-339
    • /
    • 2005
  • An instrument using thermal probe method was designed to measure thermal conductivity of liquid and solid foods. Thermal conductivity probe was designed with diameter to length ratio of 100 and diameter of 0.51 mm to minimize axial flow effect on thermal conductivity measurement. Thermal conductivities of distilled/deionized water, glycerin, and beef frankfurter meat were measured at $20-80^{\circ}C$. Mean thermal conductivity values of water showed less than 2.0% difference from several reference values without using time correction factor or probe calibration constant. For glycerin, difference was less than 0.7% from reference values at $20-50^{\circ}C$. Mean values of thermal conductivity for beef frankfurter meat ranged from 0.389 to $0.350\;W/m{\cdot}K$ at $20-80^{\circ}C$.

직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법 (A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator)

  • 장훈;이우철;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

유압벌지실험을 이용한 순 티탄늄 판재의 소성유동곡선 평가(제2보) (Evaluation of plastic flow curve of pure titanium sheet using hydraulic bulge test)

  • 김영석;김진재
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.718-725
    • /
    • 2016
  • 본 논문에서는 대형 선박의 판형 열교환기 등에 널리 이용되고 있는 순 티타늄 판재의 소성변형을 유한요소해석하기 위한 기초 데이터로서 순 티타늄 판재의 유동곡선을 평가하였다. 순 티타늄 판재의 프레스 가공 시에 판재에는 국부적으로 큰 소성변형이 발생하고 있다. 그러나 기존의 단축 인장실험에서 얻을 수 있는 소성변형률이 낮아서 티타늄 판재의 가공공정 설계를 위한 유한요소해석의 정밀도를 떨어뜨리는 경우가 있다. 본 연구에서는 큰 소성변형률 까지 안정적으로 성형이 가능한 유압벌지실험을 수행하여 재료의 소성변형에서 가공경화특성을 나타내는 유동곡선으로써 진응력-진변형률 선도를 구하였고 그 결과를 인장실험 결과와 비교하였다. 순 티타늄 판재의 유압벌지실험에서 재료의 변형률은 3D 디지털 영상상관법을 이용한 ARAMIS 시스템으로 실시간 측정된다. 이 유압벌지실험으로부터는 소성 변형률이 0.65 이상 까지도 안정적으로 재료의 소성유동곡선을 얻을 수 있었으며 그 결과는 Kim-Tuan 이 문헌 17[Y.S. Kim, J.H. In, Korean Acadmia-Ind. Coop. Soc.,(be in print), 2016] 의 연구에서 제안한 가공경화식으로 잘 핏팅됨을 알 수 있었다.

Investigation of flow-regime characteristics in a sloshing pool with mixed-size solid particles

  • Cheng, Songbai;Jin, Wenhui;Qin, Yitong;Zeng, Xiangchu;Wen, Junlang
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.925-936
    • /
    • 2020
  • To ascertain the characteristics of pool sloshing behavior that might be encountered during a core disruptive accident of sodium-cooled fast reactors, in our earlier work several series of experiments were conducted under various scenarios including the condition with mono-sized solid particles. It is found that under the particle-bed condition, three typical flow regimes (namely the bubble-impulsion dominant regime, the transitional regime and the bed-inertia dominant regime) could be identified and a flow-regime model (base model) has been even successfully established to estimate the regime transition. In this study, aimed to further understand this behavior at more realistic particle-bed conditions, a series of simulated experiments is newly carried out using mixed-size particles. Through analyses, it is verified that for present scenario, by applying the area mean diameter, our previously-developed base model can provide the most appropriate predictive results among the various effective diameters. To predict the regime transition with a form of extension scheme, a correction factor which is based on the volume-mean diameter and the degree of convergence in particle-size distribution is suggested and validated. The conducted analyses in this work also indicate that under certain conditions, the potential separation between different particle components might exist during the sloshing process.

마이크로관 내 증발열전달에 관한 연구 (A Study on the Evaporative Heat Transfer in Microtubes)

  • 황윤욱;김주혁;김민수
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1113-1122
    • /
    • 2005
  • The experimental heat transfer coefficients have been measured for two-phase convective boiling in two circular microtubes with inner diameters of $430{\mu}m\;and\;792{\mu}m$. While the heat transfer was greatly affected by the heat flux in the low quality region, the mass flux played a role in the high quality region. The smaller microtube had greater heat transfer coefficients. When the heat flux is varied from $20kW/m^2\;to\;30kW/m^2\;at\;G=240kg/m^2s$, the difference between the average heat transfer coefficients of the test tube $A(D_i=430{\mu}m)$ and the test tube $B(D_i=792{\mu}m)$ changes from $32.5\%\;to\;52.1\%$. At $G=370kg/m2^s$, the difference between the average heat transfer coefficients changes from $47.0\%\;to\;53.8\%$. A new correlation for the evaporative heat transfer coefficients in microtubes was developed by considering the following factors; the laminar flow heat transfer coefficient of liquid-phase flow, the enhancement factor of the convective heat transfer, and the nucleate boiling correction factor. The correlation developed in this study predicts the experimental heat transfer coefficients within an absolute average deviation of $8.4\%$.

인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어 (AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System)

  • 박귀근;최재원
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구 (Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus)

  • 이진성;김경수;김유일;우석민;윤승진
    • 한국해양공학회지
    • /
    • 제29권2호
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.