• 제목/요약/키워드: Flow Correction Factor

검색결과 76건 처리시간 0.021초

Development of Critical Heat Flux Correction Factor for Water under Flow Oscillation Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.242-247
    • /
    • 1996
  • Flow oscillations in boiling channels induces a drastic reduction of the (critical heat flux) CHF or premature burnout. However, most of CHF works and correlations have been focused on stable flow conditions without considering flow oscillation. Therefore to improve the understanding on flow oscillation CHF, in this paper a new CHF correction factor to predict the CHF values under flow oscillation conditions has been developed from 126 experimental data. Also to investigate the dominant factor on flow oscillation CHF parametric trends are analyzed by using the developed correction factor. The overall mean accuracy ratio of the developed correction factor is 1.033 with a standard deviation of 0.195. The RMS errors 0.198. Its assessment shows that the predictions agree well with the experimental data within 25% error bounds.

  • PDF

Three-Dimensional Flow Analysis and Improvement of Slip Factor Model for Forward-Curved Blades Centrifugal Fan

  • Guo, En-Min;Kim, Kwang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.302-312
    • /
    • 2004
  • This work developed improved slip factor model and correction method to predict flow through impeller in forward-curved centrifugal fan. Both steady and unsteady three-dimensional CFD analyses were performed to validate the slip factor model and the correction method. The results show that the improved slip factor model presented in this paper could provide more accurate predictions for forward-curved centrifugal impeller than the other slip factor models since the present model takes into account the effect of blade curvature. The correction method is provided to predict mass-averaged absolute circumferential velocity at the exit of impeller by taking account of blockage effects induced by the large-scale backflow near the front plate and flow separation within blade passage. The comparison with CFD results also shows that the improved slip factor model coupled with the present correction method provides accurate predictions for mass-averaged absolute circumferential velocity at the exit of impeller near and above the flow rate of peak total pressure coefficient.

자동변속기의 과도특성 분석을 위한 토크 컨버터의 변동 파라미터 성능 모델 개발 (Development of the Variable Parametric Performance Model of Torque Converter for the Analysis of the Transient Characteristics of Automatic Transmission)

  • 임원식;이진원
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.244-254
    • /
    • 2002
  • To enhance the acceleration performance and fuel consumption rate of a vehicle, the torque converter is modified or newly-developed with reliable analysis model. Up to recently, the one dimensional performance model has been used for the analysis and design of torque converter. The model is described with constant parameters based on the concept of mean flow path. When it is used in practice, some experiential correction factors are needed to minimize tole estimated error. These factors have poor physical meaning and cannot be applied confidently to the other specification of torque converter. In this study, the detail dynamic model of torque converter is presented to establish the physical meaning of correction factors. To verify the validity of model, performance test was carried out with various input speed and oil temperature. The effect of oil temperature on the performance is analysed, and it is applied to the dynamic model. And, to obtain the internal flow pattern of torque converter, CFD(Computational Fluid Dyanmics) analysis is carried out on three-dimensional turbulent flow. Correction factors are determined from the internal flow pattern, and their variation is presented with the speed ratio of torque converter. Finally, the sensitivity of correction factors to the speed ratio is studied for the case of changing capacity factor with maintaining torque ratio.

A PROPOSED CORRELATION FOR CRITICAL FLOW RATE OF WATER FLOW

  • KIM, YEON-SIK
    • Nuclear Engineering and Technology
    • /
    • 제47권1호
    • /
    • pp.135-138
    • /
    • 2015
  • A new correlation predicting the idealized critical mass-flow rates of water for subcooled and saturated liquid water including two-phase water flow was developed for a wide range of upstream stagnation pressures (e.g., 0.5-20.0 MPa). A choking correction factor dependent on the upstream stagnation pressure and subcooled temperature was introduced into a new correlation, and its values were suggested to satisfy the idealized nozzle data within 10% error ranges. The suggested correlation will be instructive and helpful for related studies and/or engineering works.

원심다익송풍기의 미끄럼 계수에 대한 연구 (Study on The Slip Factor Model for Multi-Blades Centrifugal Fan)

  • 구오엔민;김광용;서성진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.111-115
    • /
    • 2002
  • The objective of this work is to develop improved slip factor model and correction method to predict flow through impeller in forward-curved centrifugal fan by investigating the validity of various slip factor models. Both steady and unsteady three-dimensional CFD analyses were performed with a commercial code tn validate the slip factor model and the correction method. The results show that the improved slip factor model presented in this paper could provide more accurate predictions for forward-curved centrifugal impeller than the other slip factor models since the presented model takes into account the effect of blade curvature. The comparison with CFD results also shows that the improved slip factor model coupled with the present correction method provides accurate predictions for mass-averaged absolute circumferential velocity at the exit of impeller near and above the flow rate of peaktotal pressure coefficient.

  • PDF

Cross-flow Analogy and Euler Solutions for Missile Body Aerodynamics

  • Lee, Jae-Myung;Park, Seung-O;Kim, In-Sun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권2호
    • /
    • pp.9-16
    • /
    • 2000
  • For aerodynamic design of missile bodies of non-circular cross-section, the combination of the slender body theory and the cross-flow analogy can hardly be applied owing to the lack of experimental data. An alternative is to utilize the Euler solution in the design stage. For enhanced accuracy, however, an adequate viscous correction is necessary to the Euler solution. In this work, such a procedure is examined to compensate the viscous effect by utilizing the concept of proportionality factor in cross-flow analogy. Predictions of aerodynamic coefficients combining the Euler solution and the viscous correction via proportionality factor are made for a missile body of elliptic cross-section. Results indicate that the present approach can be adopted in designing missile bodies of non-circular cross-sections.

  • PDF

토크 컨버터의 1차원 성능 모델을 이용한 유동 각도 보정 계수에 관한 연구 (A Study on the Correction Factor of Flow Angel by using the One Dimentional Performance Model of Torque Converter)

  • 임원식
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.506-517
    • /
    • 2000
  • One dimensional performance model has been used for the design of torque converter. The model is based on the concept of constant mean flow path and constant flow angle. These constant-assumed para meters make the design procedure to be simple. In practice, some parameters are usually replaced with geometric raw data and, the constant experiential correction factors have been used to minimize the design error. These factors have no definite physical meaning and so they cannot be applied confidently to the other design condition. In this study, the detail dynamic model of torque converter is presented to establish the theoretical background of correction factors. To verify the validity of theoretical model, steady state performance test was carried out on the several input speed. The oil temperature effect on the performance is analysed and adjusted. The constant equivalent flow angles are determined at a part of performance region by comparing the theoretical model and the test data. The sensitivity of correction factors to the input speeds are studied and the change of torus flow is presented.

타이어 공기압 시스템 기술을 사용한 차량의 적재중량 측정 시스템 개발 (Development of a Load Measurement System for Vehicles using Tire Pressure System Technology)

  • 박제현;이승호
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.33-39
    • /
    • 2020
  • 본 논문에서는 타이어의 물리적인 요소 중 하나인 압력정보를 이용해서 자동차의 하중 표출이 가능한 타이어 공기압 측정 기술을 사용한 차량의 적재중량 측정시스템 설계 기법을 제안한다. 제안된 기법은 하중 및 진동에 의한 노이즈 보정, 기체유량 보정, 데이터 믹서, 중량 환산 등의 4가지 과정으로 구성된다. 하중 및 진동에 의한 노이즈 보정에서는 외부충격 및 차량이 주행 중 발생하는 진동 등에 의해 타이어의 내부 압력이 상승하는 노이즈를 제거한다. 기체유량 보정 과정에서는 하중 및 진동에 의한 노이즈 보정 과정을 거친 데이터에 대하여 지면의 온도상승에 의해 타이어의 내부 압력이 상승하는 노이즈를 제거한다. 데이터 믹서 과정에서는 화물적재 시 타이어에 수직으로 전달이 되어 타이어의 압력변화에 따른 공차, 중차, 만차에 대한 하중과 압력 등을 분류하게 된다. 중량 환산 과정에서는 하중 및 진동에 의한 노이즈 보정 및 기체유량 보정을 거친 데이터를 사용하여 중량 환산 알고리즘을 통해 중량으로 표출된다. 중량 환산 알고리즘은 하중과 압력변화에 대한 선형 함수의 기울기인 중량 환산 Factor를 구하여 중량을 환산한다. 본 논문에서 제안된 타이어 공기압 측정 기술을 사용한 차량의 적재중량 측정 시스템의 정밀도를 평가하기 위해 자체적으로 테스트 베드를 구축하여 평가하였다. 하중 및 진동에 의한 노이즈 보정 결과와 기체 유량 데이터 보정 결과는 신뢰성 있는 결과를 나타내었다. 또한 중량 정밀도 반복 실험도 국내 업체 기준치인 90% 보다 우수한 중량 정밀도를 나타내었다.

기후변화 시나리오 편의보정 기법에 따른 강우-유출 특성 분석 (Analysis of Rainfall-Runoff Characteristics on Bias Correction Method of Climate Change Scenarios)

  • 금동혁;박윤식;정영훈;신민환;류지철;박지형;양재의;임경재
    • 한국물환경학회지
    • /
    • 제31권3호
    • /
    • pp.241-252
    • /
    • 2015
  • Runoff behaviors by five bias correction methods were analyzed, which were Change Factor methods using past observed and estimated data by the estimation scenario with average annual calibration factor (CF_Y) or with average monthly calibration factor (CF_M), Quantile Mapping methods using past observed and estimated data considering cumulative distribution function for entire estimated data period (QM_E) or for dry and rainy season (QM_P), and Integrated method of CF_M+QM_E(CQ). The peak flow by CF_M and QM_P were twice as large as the measured peak flow, it was concluded that QM_P method has large uncertainty in monthly runoff estimation since the maximum precipitation by QM_P provided much difference to the other methods. The CQ method provided the precipitation amount, distribution, and frequency of the smallest differences to the observed data, compared to the other four methods. And the CQ method provided the rainfall-runoff behavior corresponding to the carbon dioxide emission scenario of SRES A1B. Climate change scenario with bias correction still contained uncertainty in accurate climate data generation. Therefore it is required to consider the trend of observed precipitation and the characteristics of bias correction methods so that the generated precipitation can be used properly in water resource management plan establishment.

전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계 (Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit)

  • 고석철;임성훈;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF