• Title/Summary/Keyword: Flow Chart

Search Result 261, Processing Time 0.023 seconds

Clinical application of Whidam's Su-Gi therapy to Shoulder Pain (견비통에 대한 휘담식 수기요법의 임상 적용)

  • Hun Mo Ahn;Sam Sik Na;Han Joo Kang
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • Objective : This report is to introduce the clinical application of Whidam's Su-Gi therapy to shoulder pain. Methods : Whidam's Su-Gi therapy for shoulder pain first identifies for red flags in order to select a person to be treated in korean medicine. After performing shoulder joint mobility evaluation and Su-Gi treatment, determine the disadvantage, and determine the mobility evaluation and Su-Gi treatment route of the shoulder, the shoulder blade, and cervical vertebrae. The advantage and pain are evaluated by a manual exercise test. After performing Su-Gi therapy according to the evaluation at each stage, pain and dysfunction are reevaluated to check the negative and proceed to the next step. Conclusions : The clinical application of Whidam's Su-Gi therapy to shoulder pain was organized around the correlation between the shoulder joint, the shoulder, the shoulder blade, and cervical vertebrae, and a medical flow chart was constructed away from the listed description method.

A Study on the Field Application of Automatic Grouting System (자동화 그라우팅 기법의 현장적용성에 관한 연구)

  • Do, Jongnam;Park, Junghwan;Choi, Dongchan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2012
  • In Korea, grouting has been mostly designed and constructed by experiences without expert knowledge and theoretical study. So there are a lot of problems related to the quality and safty of grouting. Therefor, in this paper the quality management skills and method were discussed through out by using the auto-grouting method and field test of grouting for the construction. Through the limit water injection test of the soil, it make the optimum injection pressure and injection speed of grouting, and through the lugeon test of the rock, it make assess the permeability of before and after grouting. In order to prevent the hydraulic fracture of soil and break away from the grouts if it apply four kinds of mode of grouting stop criteria, injection effects can be improved. From the above characteristcs designers evalute the fitness values of injection pressure(p), injection speed(q) and grouting penetration time(t). So far, to record and manage pressure(p) and speed(q) of grouting autographic devices such as intergation flow-meter usually record data in a roll of paper. Intergration flow-meter can record grouting flow quantity exactly, but the recorded pressures differ from the any basis such as intitial, intermediate and final point. Therefore, it has been argued that is a need of reliable method to describe the connection between the pressure recorded by an intergration flow-meter and the special properties of the grouting target ground. auto-grouting method can describe the reliable connection between the grouting pressure and the special properties of the grouting target ground. So, in this paper by using auto-grouting method, it is expected that to secure basis of quality control techniques construction.

Comparative analysis on darcy-forchheimer flow of 3-D MHD hybrid nanofluid (MoS2-Fe3O4/H2O) incorporating melting heat and mass transfer over a rotating disk with dufour and soret effects

  • A.M. Abd-Alla;Esraa N. Thabet;S.M.M.El-Kabeir;H. A. Hosham;Shimaa E. Waheed
    • Advances in nano research
    • /
    • v.16 no.4
    • /
    • pp.325-340
    • /
    • 2024
  • There are several novel uses for dispersing many nanoparticles into a conventional fluid, including dynamic sealing, damping, heat dissipation, microfluidics, and more. Therefore, melting heat and mass transfer characteristics of a 3-D MHD Hybrid Nanofluid flow over a rotating disc with presenting dufour and soret effects are assessed numerically in this study. In this instance, we investigated both ferric sulfate and molybdenum disulfide as nanoparticles suspended within base fluid water. The governing partial differential equations are transformed into linked higher-order non-linear ordinary differential equations by the local similarity transformation. The collection of these deduced equations is then resolved using a Chebyshev spectral collocation-based algorithm built into the Mathematica software. To demonstrate how different instances of hybrid/ nanofluid are impacted by changes in temperature, velocity, and the distribution of nanoparticle concentration, examples of graphical and numerical data are given. For many values of the material parameters, the computational findings are shown. Simulations conducted for different physical parameters in the model show that adding hybrid nanoparticle to the fluid mixture increases heat transfer in comparison to simple nanofluids. It has been identified that hybrid nanoparticles, as opposed to single-type nanoparticles, need to be taken into consideration to create an effective thermal system. Furthermore, porosity lowers the velocities of simple and hybrid nanofluids in both cases. Additionally, results show that the drag force from skin friction causes the nanoparticle fluid to travel more slowly than the hybrid nanoparticle fluid. The findings also demonstrate that suction factors like magnetic and porosity parameters, as well as nanoparticles, raise the skin friction coefficient. Furthermore, It indicates that the outcomes from different flow scenarios correlate and are in strong agreement with the findings from the published literature. Bar chart depictions are altered by changes in flow rates. Moreover, the results confirm doctors' views to prescribe hybrid nanoparticle and particle nanoparticle contents for achalasia patients and also those who suffer from esophageal stricture and tumors. The results of this study can also be applied to the energy generated by the melting disc surface, which has a variety of industrial uses. These include, but are not limited to, the preparation of semiconductor materials, the solidification of magma, the melting of permafrost, and the refreezing of frozen land.

Process Planning for Finishing Works of High-rise Residential Buildings Project (고층 공동주택 마감공사의 공정계획 프로세스)

  • Baek, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.110-117
    • /
    • 2017
  • In the construction of high-rise residential buildings in which the finishing works are done repetitively in each housing unit, the construction period and cost can be reduced, while maintaining the quality, if the work process is properly managed in order for the resources to be input continuously. Time management methods such as the Bar Chart, CPM and LOB are not appropriate, due to the difficulties involved in the diagraming of repetitive works and applying them to the project. The Tact method also has difficulties in maintaining a constant work flow and needs significant effort and cooperation from the subcontractors to allocate the resources consistently. Partitioning, base works for finishing, floor mortar plastering and the final finishing work are done sequentially in residential buildings projects, and there are many repetitive activities which differ in terms of the work method, work area and productivity. If these repetitive activities are synchronized or converged toward the last work area, the goal of process management can be achieved effectively. Therefore, a process planning method for the finishing works of residential building projects is proposed, which takes into consideration elements, such as the sequential relation between the activities in each housing unit and classification of repetitive works in terms of their management method, work area and production rate, for the continuous input of resources into the housing units.

Analysis of Natural Ventilation Rates of Venlo-type Greenhouse Built on Reclaimed Lands using CFD (전산유체역학을 통한 간척지 내 벤로형 온실의 자연환기량 분석)

  • Lee, Sang-Yeon;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Yeo, Uk-Hyeon;Park, Se-Jun;Kim, Rack-Woo;Jo, Ye-Seul;Lee, Seung-No
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.21-33
    • /
    • 2015
  • Recently, the Korean government announced a new development plan for a large-scale greenhouse complex in reclaimed lands. Wind environments of reclaimed land are entirely different from those of inland. Many standard books for ventilation design didn't include qualitative standard for natural ventilation. In this study, natural ventilation rates were analyzed to suggest standard for ventilation design of venlo type greenhouse built on reclaimed land. CFD (Computational Fluid Dynamics) simulation models were designed according to the number of spans, wind conditions and vent openings. The wind profile at a reclaimed land was designed using ESDU (Engineering Sciences Data Unit) code. Using the designed CFD simulation model, ventilation rates were computed using mass flow rate and tracer gas decay method. Additionally computed natural ventilation rates were evaluated by comparing with ventilation requirements. As a result of this study, ventilation rates were decreased with increasing of the number of spans. Ventilation rates were linearly increased with increasing of wind speed. When the wind speed was $1.0\;m{\cdot}s^{-1}$, only side vent was open and wind direction was $45^{\circ}$, homogeneity of ventilation rate at 0~1 m height is the worst. Finally, chart for computing natural ventilation rate was suggested. The chart was expected to be used for establishing standard of ventilation design.

A Study on the Stability Control Method of Soft and Polluted Silt Soils (연약한 실트지반과 오염된 실트지반의 안정관리 방법에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.5-16
    • /
    • 2008
  • This study investigated the existing theoretical backgrounds in order to examine the stability control method of lateral flow caused by the Plasticity of soils when unsymmetrical surcharge works on polluted soils and then compared and analyzed the results measured through model tests. Ultimate bearing power of ML and $ML_{p1}$ and $ML_{p2}$ obtained at surcharge(q)-settlement$(S_v)$ curve showed similar trends to ultimate bearing power obtained from control chart of deflection $(S_v-Y_m)$ by Tominaga.Hashimoto, that of $S_v-(Y_m/S_v)$ by Matsuo.Kawamura and that of $(q/Y_m)-q$ by Shibata.Sekiguchi and so it is considered that it has no problem in actual applicability. ${S_v-(Y_m/S_v)}$ of control chart of $ML_{p1}$ by Matsuo.Kawamura showed smaller value than ultimate bearing capacity value from surcharge-settlement curve $(q-S_v)$. Expression of ML of fracture baseline at stability control charge by Matsuo Kawamura is ${S_v=3.21exp}\{-0.48(Y_m/S_v)\}$ and expression of $ML_{p1}$ is ${S_v=3.26exp}\{-0.96(Y_m/S_v)\}$ and expression of $ML_{p2}$ is ${S_v=6.33exp}\{-0.45(Y_m/S_v)\}$.

A Study on the Method and Work Measurement for Productivity Improvement of Clothing Products-With concentration in MTM Analysis- (의류제품의 생산성 향상을 위한 방법 및 작업측정에 관한 연구-MTM법을 중심으로-)

  • 김옥경;이순흥
    • Journal of the Korean Society of Costume
    • /
    • v.41
    • /
    • pp.185-206
    • /
    • 1998
  • The purpose of this study was to improve productivity for maximum effects with the present equipments and staff. This study compared and analyzed the mea-sured time by using stop watch method and MTM, which was the new measuring method. The flow and results of this study were as follows: 1. This study investigated the theoretical background the efficiency for production management, and the way of productivity improvement through documentary research. 2. Setting up the standard flow on the experi-mental company production, making out a process chart and measuring the actual working hour. 3. The study measured the allowance time applying work sampling. 4. Each process of the movement analysis was filmed by video to use basic data. 5. MTM analysis was taken by choosing 10 processes from front bodice according to the basic movement of MTM. Through the results, this study exclude unneccesary movements and suggest a method for working ways. 6. Using the actual working hour measured by a stop watch calculated the pitch time and presumed the amount of daily productivity. 7. The result of the work sampling came out as 38% of allowance rate. It was 13% higher than the standard amount of woman's jacket allowance rate, which was 25%. The most influencing factor was work discussion. That was because there were commuication problem of the work way between the operator and leader. More adequate use of flow table and level passing table was needed. There were the problems that inappropriate places and sizes made the distance of movements longer and often needed more adjustment of works and surroundings. To prevent breakdowns equipments check ups were necessary before works. 8. The results of MTM analysis were as follow : the time was reduced 40% than the actual measured time by a stop watch. This was because the leveling of the operator was included in the real calculation. Also, leveling was included in MTM analysis and all the conditions were standarized. Therefore MTM method was a scientidic measuring way of establishing the standard time. The presented method of this study, suggested an ideal method eliminating unneccesary motions, and presented standardization of works. Improvement of working methods, work condition and simplifying motions in each 10 processes reduced the working time from total 656 seconds to 301 seconds. 9. The way and time of working was linked together in the MTM analysis methods. Thus data from MTM help suggest not only establishing standard time but also establishing stan-dard work. Plus it includes various ability for improvements of working ways. So it is an objective method which can be widely used in other work studies. 10. The function of a time study is to determine the amount of work produced with a given method. The work rate is used to establish the cost of labor. The wage of worker must be calculated per unit time which is deter-mined before the time study is made. This study tried to introduce the incentive rule for deciding wages according to the standard time by MTM method.

  • PDF

The Cause of Abnormal Tidal Residuals Along the Coast of the Yellow Sea in November 2013 (황해연안의 2013년 11월 이상조위편차 발생 원인)

  • Kim, Ho-Kyun;Kim, Young Taeg;Lee, Dong Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.4
    • /
    • pp.344-353
    • /
    • 2016
  • The cause of abnormal tidal residuals was examined by analyzing sea levels, sea surface atmospheric pressures, winds at ten tide stations, and current, measured at the coast of the Yellow Sea from the night of November $24^{th}$ to the morning of the $25^{th}$ in 2013, along with weather chart. Additionally, the cross-correlations among the measured data were also examined. The 'abnormal tidal residuals' mentioned in this study refer to differences between maximum and minium tidal residuals. The largest abnormal tidal residual was identified to be a difference of 176 cm occurring over 4 hours and 1 minute at YeongJongDo (YJD) with a maximum tidal residual of 111 cm and minimum of -65 cm. The smallest abnormal tidal residual was 68 cm at MoSeulPo (MSP) during 8 hours 52 minutes. The cause of these abnormal tidal residuals was not a meteo-tsunami generated by an atmospheric pressure jump but wind generated by the pressure patterns. The flow speed due to these abnormal tidal residuals as measured at ten tide stations was not negligible, representing 16 ~ 41 % of the annual average ebb current speed. From the cross correlation among the tidal residuals, winds, and tidal residual currents, we learned the northern flow, due to southerly winds, raised the sea level at Incheon when a low pressure center located on the left side of the Korean Peninsula. After passing the Korean Peninsula, a southern flow due to northerly winds decreased the sea level.

Clinical Application of M-number for Aortic Cannulas During Cardiopulmonary Bypass (심폐바이패스시 대동맥캐늘라에 대한 M-NUMBER의 임상 적용)

  • 김원곤;박성식
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.510-516
    • /
    • 1996
  • Cardiopulmonary bypass cannulas are usually characterized by the French number. However this de- scription provides only the external diameter of the cannula, which gives no information about the press- ure-flow characteristics of the cannula itself. A standardized system to describe the pressure-flow characteristics of a given cannula has recently been proposed and has been termed the M-number It is reported that the pressure-flow characteristics of a particular cannula can be determined from a novo- gram or chart, if the experimentally derived M-number of the cannula is known. In this regard, we conducted an investigation to analyze correlation between experimentally and clinical y derived M-numbers using three different sizes of pediatric aortic cannulas in fifty cardiac patients on cardiopulmonary bypass. The clinical and experimental M-numbers showed a strong correlation. The clinical M-numbers were typically 0.)5 to 0.55 greater than the experimental M-numbers. The clinical M-numbers also showed an inverse relationship to the temperature change of the patient, most probably due to an increase in blood viscosity from hypothermia. This inverse clinical M-numbersltemperature re- lationship was more marked in higher M-number cannulas. The clinical data obtained in this study suggest that the experimentally derived M-numbers correlated strongly with the clinical performance of the cannula with the significant influence of the temperature.

  • PDF

Radiation Oncology Digital Image Chart 8nd Digital Radiotherapv Record System at Samsung Medical Center (디지털 화상 병력 시스템과 디지털 방사선치료 기록 시스템의 개발과 사용 경험)

  • Huh Seung Jae;Ahn Yong Chan;Lim Do Hoon;Cho Chung Keun;Kim Dae Yong;Yeo Inhwan;Kim Moon Kyung;Chang Seung Hee;Park Suk Won
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2000
  • Background :The authors have developed a Digital image chart(DIC) and digital Radiotherapy Record System (DRRS). We have evaluated the DIC and DRRS for reliability, usefulness, ease of use, and efficiency. Materials and Methods :The basic design of the DIC and DRRS was to build an digital image database of radiation therapy Patient records for a more efficient and timely flow of critical image information throughout the department. This system is a submit of comprehensive radiation oncology management system (C-ROMS) and composed of a picture archiving and communication system (PACS), a radiotherapy information database, and a radiotherapy imaging database. The DIC and DRRS were programmed using Delphi under a Windows 95 environment and is capable of displaying the digital images of patients identification photos, simulation films, radiotherapy setup, diagnostic radiology images, gross lesion Photos, and radiotherapy Planning isodose charts with beam arrangements. Twenty-three clients in the department are connected by Ethernet (10 Mbps) to the central image server (Sun Ultra-sparc 1 workstation). Results :From the introduction of this system in February 1998 through December 1999, we have accumulated a total of 15,732 individual images for 2,556 patients. We can organize radiation therapy in a 'paperless' environment in 120 patients with breast cancer. Using this system, we have succeeded in the prompt, accurate, and simultaneous access to patient care information from multiple locations throughout the department. This coordination has resulted in improved operational efficiency within the department. Conclusion :The authors believe that the DIC and DRRS has contributed to the improvement of radiation oncology department efficacy as well as to time and resource savings by providing necessary visual information throughout the department conveniently and simultaneously. As a result, we can also achieve the 'paperless' and 'filmless' practice of radiation oncology with this system.

  • PDF