• 제목/요약/키워드: Floor rigidity

검색결과 35건 처리시간 0.024초

Pseudo-dynamic test of the steel frame - Shear wall with prefabricated floor structure

  • Han, Chun;Li, Qingning;Jiang, Weishan;Yin, Junhong;Yan, Lei
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.431-445
    • /
    • 2016
  • Seismic behavior of new composite structural system with a fabricated floor was studied. A two-bay and three-story structural model with the scale ratio of 1/4 was consequently designed. Based on the proposed model, multiple factors including energy dissipation capacity, stiffness degradation and deformation performance were analyzed through equivalent single degree of freedom pseudo-dynamic test with different earthquake levels. The results show that, structural integrity as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without concrete topping. It is proved that the cast-in-place floor in areas with high seismic intensity can be replaced by the prefabricated floor without pouring surface layer. The results provide a reliable theoretical basis for the seismic design of the similar structural systems in engineering application.

면내 압축력을 받는 플랫 플레이트 슬래브에 대한 모멘트 증대법 (Moment Magnifier Method for RC Flat Plate Subject to Combined Axial Compressive and Floor Load)

  • 박홍근
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.243-254
    • /
    • 1999
  • 면외 바닥하중과 면내 압축력을 받는 플랫플레이트 슬래브에 적용할 수 있는 모멘트증대법을 개발하기 위하여 수치해석연구를 실시하였다. 수치해석연구를 위하여 재료와 기하학적 비선형효과를 고려한 비선형 유한요서 해석프로그램을 개발하였으며, 해석모델로서 국내 철근콘크리트계산규준의 직접설계법에 의하여 설계된 플랫플레이트 슬래브를 사용하였다. 본 연구는 지배하중조건인 수직하중후 1축압축력의 조합하중을 받는 슬래브에 대한 좌굴하중과 모멘트증대계수를 제안하였다. 좌굴하중은 두 개의 요소, 즉 슬래브의 기하학적 형태의 영향을 나타내는 좌굴계수와 압축과 인장 균열에 의한 손상정도를 나타내는 유효휨강성으로 정의된다. 변수연구를 통하여 좌굴계수와 유효휨강성의 변화를 연구하였으며, 이 수치해석결과를 바탕으로 좌굴계수와 유효휨강성의 설계값과, 이를 사용하는 모멘트증대법을 제안하였다.

Seismic demand assessment of semi-rigid steel frames at different performance points

  • Sharma, Vijay;Shrimali, Mahendra K.;Bharti, Shiv D.;Datta, Tushar K.
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.713-730
    • /
    • 2021
  • The seismic performance of rigid steel frames is widely investigated, but that of semi-rigid (SR) steel frames are not studied extensively, especially for near-field earthquakes. In this paper, the performances of five and ten-story steel SR frames having different degrees of semi-rigidity are evaluated at four performance points in the four different deformation states, namely, the elastic, elasto-plastic, plastic, and near collapse states. The performances of the SR frames are measured by the response parameters including the maximum values of the top floor displacement, base shear, inter-story drift ratio, number of plastic hinges, and SRSS of plastic hinge rotations. These response parameters are obtained by the capacity spectrum method (CSM) using pushover analysis. The validity of the response parameters determined by the CSM is evaluated by the results of the nonlinear time history analysis (NLTHA) for both near and far-field earthquakes at different PGA levels, which are consistent with the performance points. Results of the study show that the plastic hinges of SR frame significantly increase in the range of plastic to near-collapse states for both near and far-field earthquakes. The effect of the degree of semi-rigidity is pronounced only at higher degrees of semi-rigidity. The predictions of the CSM are fairly well in comparison to the NLTHA.

문형식 표지판 지지대의 모멘트 분포와 변형에 대한 해석 및 안정성 분석

  • 임형태;김소형;박성현
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제4회(2015년)
    • /
    • pp.251-256
    • /
    • 2015
  • In this paper, an systematic approach is presented, in which the bridge-type traffic sign structure is body out by CSDDA PrePost Processor. There is dead load and wind load that is working on the structure which will make force and moment. Analyzied the stress distribution of the standard form and by changing the shape, compared the safety in terms of deflection and stress (with the standard form) to know the effect of each component in the bridge-type traffic sign structure. The safety of deflection and stress is evaluated by maximum distance/100) and ASIC code respectively. The standard form of bridge-type traffic sign structure is established by two pairs of pillar and two pairs of floor beam. Replaced the links which is consist of flange and screws as the torsion spring and nm our analysis program. By adjusting variable of rigidity modulus of torsion spring, moment between column and beam is controled depending on value of rigidity modulus.

  • PDF

Modal rigidity center: it's use for assessing elastic torsion in asymmetric buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • 제1권2호
    • /
    • pp.163-175
    • /
    • 2010
  • The vertical axis through the modal center of rigidity (m-CR) is used for interpreting the code torsional provisions in the design of eccentric multi-story building structures. The concept of m-CR has been demonstrated by the author in an earlier paper and the particular feature of this point is that when the vertical line of the centers of mass at the floor levels is passing through m-CR, minimum base torsion is developed. For this reason the aforesaid axis is used as reference axis for implementing the code provisions required by the equivalent static analysis. The study examines uniform mixed-bent-type multistory buildings with simple eccentricity, ranging from torsionally stiff to torsionally flexible systems. Using the results of a dynamic response spectrum analysis as a basis for comparisons, it is shown that the results of the code static design are on the safe side in torsionally stiff buildings, but unable to predict the required strength of bents on the stiff side of systems with a predominantly torsional response. Suggestions are made for improving the code provisions in such cases.

Spontaneous Intracranial Epidural Hematoma Originating from Dural Metastasis of Hepatocellular Carcinoma

  • Kim, Byoung-Gu;Yoon, Seok-Mann;Bae, Hack-Gun;Yun, Il-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권2호
    • /
    • pp.166-169
    • /
    • 2010
  • Spontaneous intracranial epidural hematoma (EDH) due to dural metastasis of hepatocellular carcinoma is very rare. A 53-year-old male patient with hepatocellular carcinoma, who was admitted to the department of oncology, was referred to department of neurosurgery because of sudden mental deterioration to semicoma with papillary anisocoria and decerebrate rigidity after transarterial chemoembolization for hepatoma. Brain computed tomography (CT) revealed large amount of acute EDH with severe midline shifting. An emergent craniotomy and evacuation of EDH was performed. Active bleeding from middle cranial fossa floor was identified. There showed osteolytic change on the middle fossa floor with friable mass-like lesion spreading on the overlying dura suggesting metastasis. Pathological examination revealed anaplastic cells with sinusoidal arrangement which probably led to spontaneous hemorrhage and formation of EDH. As a rare cause of spontaneous EDH, dural metastasis from malignancy should be considered.

Evaluation of Impact Sound Insulation Properties of Light-Framed Floor with Radiant Floor Heating System

  • Nam, Jin-Woo;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.75-84
    • /
    • 2002
  • In order to find out impact insulation properties, various types of current radiant floor heating systems and light-framed floors that are used in light-framed residential buildings were evaluated for two types of impact sources at the same time. Sound Pressure Level (SPL) was different from each impact sources for those spectrum patterns and peaks. In case of light-framed floor framework, the excitation position and the assumed effective vibrating area have effects on sound pressure level but it is not considerable, and Normalized SPL was reduced for each frequency by increasing the bending rigidity of joist. The mortar layer in the radiant heating system had relatively high density and high impedance, therefore, it distributed much of the impact power when it was excited, and reduced the Normalized SPL considerably. Nevertheless, Increasing a thickness of mortar layer had little influence on SPL. Ceiling components reduced the sound pressure level about 5~25 dB for each frequency. Namely, it had excellent sound insulation properties in a range from 200 to 4,000 Hz frequency for both heavy and lightweight impact sources. Also, there was a somewhat regular sound insulation pattern for each center frequency. The resilient channel reduced the SPL about 2~11 dB, irrelevant to impact source. Consequently, current radiant floor heating systems which were established in light-framed residential buildings have quite good impact sound insulation properties for both impact sources.

Numerical assessment of post-tensioned slab-edge column connection systems with and without shear cap

  • Janghorban, Farshad;Hoseini, Abdollah
    • Computers and Concrete
    • /
    • 제22권1호
    • /
    • pp.71-81
    • /
    • 2018
  • Introduction of prestressed concrete slabs based on post-tensioned (PT) method aids in constructing larger spans, more useful floor height, and reduces the total weight of the building. In the present paper, for the first time, simulation of 32 two-way PT slab-edge column connections is performed and verified by some existing experimental results which show good consistency. Finite element method is used to assess the performance of bonded and unbonded slab-column connections and the impact of different parameters on these connections. Parameters such as strand bonding conditions, presence or absence of a shear cap in the area of slab-column connection and the changes of concrete compressive strength are implied in the modeling. The results indicate that the addition of a shear cap increases the flexural capacity, further increases the shear strength and converts the failure mode of connections from shear rigidity to flexural ductility. Besides, the reduction of concrete compressive strength decreases the flexural capacity, further reduces the shear strength of connections and converts the failure mode of connections from flexural ductility to shear rigidity. Comparing the effect of high concrete compressive strengths versus the addition of a shear cap, shows that the latter increases the shear capacity more significantly.

Modified seismic analysis of multistory asymmetric elastic buildings and suggestions for minimizing the rotational response

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.39-55
    • /
    • 2014
  • A modified procedure is presented for assessing the seismic response of elastic non-proportionate multistory buildings. This procedure retains the simplicity of the methodology presented by the author in earlier papers, but it presents higher accuracy in buildings composed by very dissimilar types of bents. As a result, not only frequencies and peak values of base resultant forces are determined with higher accuracy, but also the location of the first mode center of rigidity (m1-CR). The closeness of m1-CR with the axis passing through the centers of floor masses (mass axis) implies a reduced rotational response and it is demonstrated that in elastic systemsa practically translational response is obtained when this point lies on the mass axis.Besides, when common types of buildings are detailed as planar structures under a code load, this response is maintained in the inelastic phase of their response as a result of the almost concurrent yielding of all the resisting bents. This property of m1-CR can be used by the practicing engineer as a guideline to form a structural configuration which will sustain minimum rotational response, simply by allocating the resisting elements in such a way that this point lies close to the mass axis. Inelastic multistory building structures, detailed as above, may be regarded as torsionally balanced multistory systems and this is demonstrated in eight story buildings, composed by dissimilar bents, under the ground motions of Kobe 1995 (component KJM000) and Friuli 1976 (component Tolmezzo E-W).

2개의 거더가 적용된 강플레이트 거더교의 가로보 거동에 관한 연구 (A Study on the Behavior of Cross Beams in Two-I girder steel bridges)

  • 경갑수;권순철;박경진;전준창
    • 대한토목학회논문집
    • /
    • 제26권3A호
    • /
    • pp.523-532
    • /
    • 2006
  • 2거더 강교량의 건설 효율성 등을 위해서는 구조형식, 특히 가로보를 포함하는 구조계의 거동평가에 기초한 효율적이고 합리적인 설계기준 등의 제시가 필요할 것으로 생각된다. 따라서, 본 연구에서는 2거더 강교량에서 하중전달 역할을 하는 가로보의 위치, 간격 및 강성의 영향인자가 2거더 강교량의 거동 특성에 미치는 영향을 조사하고 합리적인 가로보 배치 기준을 제시하고자 한다. 기존 2거더 강교량을 대상교량으로 선정하고 가로보 특성을 적절하게 평가할 수 있는 몇가지 구조 모델링에 대해 구조해석을 실시한 결과, 가로보의 모델은 국부적인 응력집중과 바닥판의 하중분배 효과를 고려할 수 있는 쉘요소 및 솔리드 요소가 적합할 것으로 판단된다. 이러한 쉘요소 및 솔리드 요소를 사용하여 가로보의 배치 위치, 배치 간격 및 강성을 변수로 구조해석을 실시하여 효율적인 가로보 설계기준을 제시하였다.