• Title/Summary/Keyword: Floor level

Search Result 811, Processing Time 0.027 seconds

A Study on the Reduction of the Lightweight Impact Sound Level by Floor Coverings (바닥마감재가 경량충격음 저감량 평가에 미치는 영향)

  • 정진연;이성호;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.137-142
    • /
    • 2004
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by floor coverings. The characteristics on the reduction of the lightweight impact sound level by floor coverings is as follows. The insulation level attained by floor coverings tends to be smaller in actual buildings than in public laboratories. The reduction of the impact sound level to the tape is similar to the method of adhesives. For this reason, the reduction of impact sound level by floor coverings in public laboratories can be utilized to tape. And the reduction of impact sound level by floor coverings is not influenced by the size of specimen except the specific frequency.

  • PDF

Performance of floor coverings by impact sound (실 충격원에 대한 바닥마감재 성능 분석)

  • Chung, Jinyun;Im, Jungbin;Lee, Sungchan;Kim, Kyoungwoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

A Study on the Sound Insulation Performance Elevation of Floor Structure that use Rubber chip in Apartment House (고무칩을 이용한 공동주택 바닥구조의 차음성능 향상에 관한 연구)

  • 박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.237-332
    • /
    • 2002
  • We constructed ceiling structure and floor structure for elevation of sound insulation performance of concrete slab of apartment house. And, we wished to measure heavy floor impact sound level and light floor impact sound level of these structure. As the result, light floor impact sound level interception performance of concrete slab was measured by thing that construction work of gypsum baud is important. Heavy floor impact sound level interception performance was measured by thing that it is effective that construct to thickness about 30 millimeters on concrete Slav. It was measured effectively that heavy floor impact sound level interception performance constructs rubber chip to thickness about 30 millimeters on concrete Slav.

  • PDF

Floor Impact Noise Reduction Performance of Double-Floor System in Apartments (공동주택 이중바닥구조의 바닥충격음 저감성능)

  • Baek, Gil-Ok;Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.197-202
    • /
    • 2014
  • Floor Impact Noise is a structure-borne noise which is mainly caused by vibration of concrete slabs. The majority of previous studies have focused on investigating performance of absorbing sheets on the reduction of floor impact noise. But absorbing sheets do not efficiently reduce heavy-weight floor impact noise level because it cannot absorb slab vibration, which is the fundamental noise source. In this study, double-floor system was developed in order to reduce floor impact noise level in residual buildings. This floor system reduces heavy-weight impact noise level by reducing vibration response at the center of slab, which has maximum amplitude in the 1st vibration mode. In order to identify the performance of the double-floor system, experiments were planned. Primary test parameters are span of double floor, arrangement and types of absorbing sheets.

  • PDF

The Analysis of Perceptual Levels For Floor Impact Noises in Apartments (공동주택에서의 바닥충격음 인지도 분석)

  • 김경호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.598-603
    • /
    • 2002
  • The floor impact noise in apartment buildings has been known as the most sensitively recognized environmental noise. Therefore. inhabitants perceptual evaluation of floor impact noises was investigated by a questionnaire survey. It was found that the respondents perceive the floor impact noises from the upper nor as a constant noise level. However, if there is any child on the upper floor. the respondents felt Its noise as a harshly grating level. It was also found that the larger the respondents house is. the higher their wanted level of noise isolation is. Moreover, it was revealed that the main source of the floor impact noise from the upper floor is a child at the age from six to seven. The results could be used as fundamental data for the research on impact sources and new regulations that fit to Korean perceptual aspects and characteristics.

  • PDF

A study on the Calculation of Noise Correction Coefficient on each floor for the estimation on the roadside traffic noise around the Apartment Building (도로변 공동주택의 층별 소음보정계수 산정에 관한 연구)

  • Park, Young Min;Lee, Ji Wang;Ko, Jung Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.1
    • /
    • pp.25-36
    • /
    • 2005
  • Actually, prediction formula of road traffic noise for EIA(Environmental Impact Assessment) has been used that proposed by National Institute of Environmental Research in 1999. The prediction formula, however, was calculated predicted noise level according to noise level producing on first floor, then needs to correct noise level at each floor in the case of apartment building. The investigation was carried out to calculate the correction coefficient for commonly using in EIA of large scaled apartment development areas. The noised level at each floor were measured from August 2001 to March 2002 at 31 investigation points of large scaled apartment development area in national wide. Measured data were divided and treated with 4 types as 3th floor, 5th floor, 7th floor and 10th floor and then the correction coefficients of each floor were calculated using by correlation formula according to each floor.

Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation (감성평가 기반 바닥충격음 등급화 및 수인한도 설정)

  • Kim, Sung Min;Hong, Joo Young;Jeon, Jin Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.7-9
    • /
    • 2014
  • An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the impact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classification and an acceptable level of floor impact sounds were proposed.

  • PDF

Research about correlation of slab vibration mode and heavy-weight floor impact sound (슬래브의 동특성과 중량충격음의 상관관계에 관한 연구)

  • Chung, J.Y.;Lee, S.W.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers (콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음)

  • Mun, Dae Ho;Oh, Yang Ki;Jeong, Gab Cheol;Park, Hong Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

A study on Design Planning of the National Rental Apartment's Community Space Located on Ground Level Floor for Aging Society (고령화 사회에 따른 국민임대아파트 1층 공유공간의 계획방향에 대한 연구)

  • Chae, Min Seok;Lee, Ju Hyun;Lee, Hyun Soo
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.71-79
    • /
    • 2008
  • Lower birth rate and higher elder people are serious social problem in Korea. In 2003, the total birth rate is 1.19 per person, that record is lowest among OECD country. In 2005, Korea has been the aging society with 9.0% in aged population rate. Increasing of aged population results in elder estrangement and confliction with other generations. The social problem can be solved in some degree by improving housing environment and many kinds of welfare program. This study suggests a solution of the problem by applying community space located on ground level floor. The ground level floor of apartment has many physical benefits like connection to the earth, extension, safeness for the aged and child. in case of the National Rental apartment, small residential area and high rate of elder, child, the disabled make the ground level floor useful space for community. According to case study, almost the National Rental apartment hasn't enough facilities supporting various generations and don't supply comfortable environment. So, this study presents how to design the National Rental Apartment's community space located on ground level floor.