• 제목/요약/키워드: Floor Response Spectrum

검색결과 82건 처리시간 0.022초

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.

Improvement of aseismic performance of a PGSFR PHTS pump

  • Lee, Seong Hyeon;Lee, Jae Han;Kim, Sung Kyun;Kim, Jong Bum;Kim, Tae Wan
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1847-1861
    • /
    • 2020
  • A design study was performed to improve the limit aseismic performance (LSP) of a primary heat transport system (PHTS) pump. This pump is part of the primary equipment of a prototype generation IV sodium-cooled fast reactor (PGSFR). The LSP is the maximum allowable seismic load that still ensures structural integrity. To calculate the LSP of the PHTS pump, a structural analysis model of the pump was developed and its dynamic characteristics were obtained by modal analysis. The floor response spectrum (FRS) initiated from a safety shutdown earthquake (SSE), 0.3 g, was applied to the support points of the PHTS pump, and then the seismic induced stresses were calculated. The structural integrity was evaluated according to the ASME code, and the LSP of the PHTS pump was calculated from the evaluation results. Based on the results of the modal analysis and LSP of the PHTS pump, design parameters affecting the LSP were selected. Then, ways to improve the LSP were proposed from sensitivity analysis of the selected design variables.

복수의 동적하중을 받는 바닥판 구조물의 응답스펙트럼 해석 (Response Spectrum Analysis of Floor Structure Subjected to Group Dynamic Loads)

  • 김태호;한덕전
    • 한국공간구조학회논문집
    • /
    • 제8권1호
    • /
    • pp.57-67
    • /
    • 2008
  • 건축구조물의 응답스펙트럼 해석법은 주로 내진설계를 위하여 많이 사용되고 있고 시간이력 해석법은 기계, 설비, 사람에 의한 하중 등이 건축물에 가해지는 경우에 많이 사용되고 있다. 응답스펙트럼 해석법과 시간이력해석법을 비교해 보면 시간이력 해석법은 복잡하고 분석이 어려우며 해석에 시간을 많이 필요로 하고 구조물이 복잡해질 경우에는 해석이 어려운 경우도 있다. 본 연구에서는 응답스펙트럼해석법을 이용하여 기계나 사람에 의한 하중을 받는 건축물 바닥판의 연직응답을 구하고자 한다. 이를 위하여 모드조합에서는 CQC기법을 적용하였으며, 사람의 활동을 중심으로 하중간의 상관관계를 분석하여 해석에 적용하였다. 제안방법은 시간이력해석결과와도 비교하였으며 하중간의 상관계수는 복수의 하중을 받는 바닥판구조물의 응답스펙트럼 해석에 반드시 고려해야 하는 결과를 얻었다.

  • PDF

고감쇠고무 적층받침의 경년열화를 고려한 원전구조물의 지진응답 (Seismic Response of Seismically-Isolated Nuclear Power Plants considering Age-related Degradation of High Damping Rubber Bearing)

  • 박준희;전영선;최인길
    • 한국전산구조공학회논문집
    • /
    • 제26권2호
    • /
    • pp.131-138
    • /
    • 2013
  • 면진장치는 상부구조물의 지진력을 감소시키는데 크게 기여하지만, 고감쇠고무 적층받침에 사용되는 고무재료는 시간이 경과함에 따라 열화되어 상부구조물의 동특성과 기기들의 지진응답에 영향을 줄 수 있다. 따라서 면진장치의 경년열화를 고려한 구조물의 지진응답을 분석하는 연구가 필요하다. 본 연구에서는 기존 문헌을 통하여 분석된 고무의 경년열화 특성을 사용하여 면진장치를 모델링하였다. 면진된 원전의 지진응답을 평가하기 위하여 격납건물과 보조건물을 대상 구조물로 선정하고, 진동수 성분이 다양한 입력지진동을 사용하여 구조물의 고유진동수, 최대지진응답, 층응답스펙트럼을 시간의 경과에 따라 분석하였다. 해석결과에 의하면 면진장치의 경년열화에 의하여 지진응답이 소폭 증가하였으며, 면진장치가 설치된 후 20년까지 지진응답의 증가율이 크게 나타나므로 이 기간에 상세한 검사가 시행되어야 할 것이다.

장주기 지진동을 고려한 건축물 및 비구조요소의 가속도 응답 증폭비 (A Study on the Acceleration Response Amplification Ratio of Buildings and Non-structural Components Considering Long-Period Ground Motions)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2023
  • Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings' acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.

상용 유한요소해석 프로그램을 이용한 축류송풍기의 내진해석 (Seismic Analysis of an Axial Blower Using a Commercial FEM Code)

  • 정진태;임형빈;김강성;허진욱
    • 한국소음진동공학회논문집
    • /
    • 제12권3호
    • /
    • pp.181-186
    • /
    • 2002
  • A seismic analysis is one of crucial design procedures of an axial blower used in nuclear power Plants. The blower should be operated even in ar emergency such as an earthquake. The blower should be designed in order to stand against an earthquake. For the seismic analysis, Ive perform the modal analysis and then evaluate the required response spectrum (PRS) from the given floor response spectrum (FRS). A finite element model of the blower is established by using a commercial FEM code of ANSYS. After the finite element modeling. the natural frequencies. the mode shapes and the participation factors are obtained from the modal analysis. The PRS is acquired by a numerical approach on the basis of the principle of mode superposition. We verify the structura safety of the axial blower and confirm the validity of the present seismic analysis results.

하나로 원자로 수조내 사각보의 동특성 평가 (Evaluation of Dynamic Characteristics of the Box Beam of HANARO Reactor Pool)

  • 김성호;단호진;류정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.525-525
    • /
    • 2005
  • This study is for the seismic analysis and the structural integrity evaluation of the box beam for supporting nuclear fuel-transfer-basket of the HANARO reactor pool. For performing the seismic analysis and evaluating the structural integrity in air or submerged condition, the finite element model of the fuel-transfer-basket and its supporting box beam(the coupled model) was developed. The hydrodynamic effect is also considered by using added mass concept. The seismic response spectrum analyses of the coupled model under the design floor response spectrum loads of Safe Shutdown Earthquake(SSE) were performed. Through the numerical experiments, the analysis results show that the stress values of the coupled model lot the structural integrity are within the ASME Code limits.

  • PDF

중량충격원에 따른 콘크리트 바닥판의 차음특성 분석 및 평가에 관한 연구 (Analysis and Evaluation of Impact Sound Insulation of Concrete Floor Structures in Response to Characteristics of Heavy-weight Impact Sources)

  • 유승엽;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1062-1068
    • /
    • 2009
  • In this study, the impact force levels of bang machine and impact ball were measured, then the heavy-weight impact sounds generated by the bang machine and impact ball were investigated. It was found that the heavy-weight impact sources generated through modal excitation, and the impact force of the impact ball was similar to that of real impact source. The heavy-weight impact sounds were also measured in the real apartments with different slab thickness and floor structures. The results showed that the floor impact sound levels in terms of $L_{iFmax,AW}$, generated by impact ball sounds were reduced by using the resilient isolators. The frequency characteristics of heavy-weight impact sounds at 125 and 250 Hz were consistent with the characteristics of impact force spectrum. However, the difference between the impact sounds and the impact forces were found at 63 and 500 Hz due to the resonance of the floor structure and flanking noise, respectively.

복수 절점에 가진되는 건물 바닥판의 해석을 위한 응답스펙트럼 해석법의 응용 (Application of Response Spectrum Method for Analysis of a Floor System Subjected to Dynamic Loads on Multiple Locations)

  • 김태호;이동근
    • 한국전산구조공학회논문집
    • /
    • 제15권1호
    • /
    • pp.21-32
    • /
    • 2002
  • 일반적으로 응답스펙트럼 해석법은 건물의 지진해석에 널리 사용되고 있지만 기계하중이나 이동하중 등에 의하여 발생하는 진동에 대한 해석에는 시간이력해석이 주로 사용되고 있다. 그런데, 시간이력해석법은 정확한 반면 매우 복잡하고 어려우며 많은 시간을 필요로 한다. 따라서, 본 논문에서는 동적하중을 받는 구조물의 최대응답을 응답스펙트럼해석법을 이용하여 간편하게 계산하는 방법을 제시하고자 한다. 우선, 이 해석법의 해석과정에 대하여 알아보았으며, 복수절점에 동적 하중을 받는 경우에 대해서 해석시간 및 메모리를 줄이는 방법을 제시하였다. 다음으로는 이동하중을 받는 경우에 대하여 구조물의 최대응답을 구하는 방법에 대하여 알아보았다. 마지막으로 예제를 통하여 시간이력해석을 수행하여 얻은 최대응답과 응답스펙트럼해석에 의한 최대응답을 비교하여 제시한 해석법의 정확성을 확인하였다.

후쿠시마 원자력발전소 지진 계측 기록 분석을 통한 지진파의 공간적 변화 특성 평가 (Spatial Variation Characteristics of Seismic Motions through Analysis of Earthquake Records at Fukushima Nuclear Power Plant)

  • 하정곤;김미래;김민규
    • 한국지진공학회논문집
    • /
    • 제25권5호
    • /
    • pp.223-232
    • /
    • 2021
  • The spatial variation characteristics of seismic motions at the nuclear power plant's site and structures were analyzed using earthquake records obtained at the Fukushima nuclear power plant during the Great East Japan Earthquake. The ground responses amplified as they approached the soil surface from the lower rock surface, and the amplification occurred intensively at about 50 m near the ground. Due to the soil layer's nonlinear characteristics caused by the strong seismic motion, the ground's natural frequency derived from the response spectrum ratio appeared to be smaller than that calculated from the shear wave velocity profile. The spatial variation of the peak ground acceleration at the ground surface of the power plant site showed a significant difference of about 0.6 g at the maximum. As a result of comparing the response spectrums at the basement of the structure with the design response spectrum, there was a large variability by each power plant unit. The difference was more significant in the Fukushima Daiichi site record, which showed larger peak ground acceleration at the surface. The earthquake motions input to the basement of the structure amplified according to the structure's height. The natural frequency obtained from the recorded results was lower than that indicated in the previous research. Also, the floor response spectrum change according to the location at the same height was investigated. The vertical response on the foundation surface showed a significant difference in spectral acceleration depending on the location. The amplified response in the structure showed a different variability depending on the type of structure and the target frequency.