• Title/Summary/Keyword: Floor Plate

Search Result 247, Processing Time 0.031 seconds

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

Moistureproof Characteristics of Woodboard Types with Surface Thermal Changes (목질 보드류의 표면 열변화에 따른 접촉각(방습) 특성)

  • Shin, Sang-Ho;Liim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.161-162
    • /
    • 2020
  • In this study, as part of securing related data, water droplets were dropped on the upper part of the wooden board for flooring in an environment such as floor heating, and the degree of absorption according to the surface temperature change was tested. The test results showed that the contact angle of the surface was low (25℃→40℃) or the droplet was absorbed into the small plate and disappeared. The contact angle of the OSB and MDF was decreased within 30 minutes, but the surface water droplet was maintained longer than the plywood. This is because the surface is coated with hydrophobicity unlike the plywood, but moisture absorption in the cross section after the second processing will not be prevented and it will lead to defect occurrence problem.

  • PDF

Characteristic of Buckling and Ultimate Strength of the Perforated Stiffened Plate (유공보강판의 좌굴 및 극한강도 특성에 관한 연구)

  • Park Joo-Shin;Ko Jae-Yong;Oh Kyoung-Gun
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.439-446
    • /
    • 2006
  • In ship structures many of the structural plates have cutouts, for example, at inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has a cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed In general, actual ship structure adopted reinforcement of stiffener around the cutout in order to preventing from buckling so it need to examine a buckling and ultimate strength behaviour considering a cutout because In many ship yards used class rule for calculating buckling strength but it is difficult to evaluate perforate stiffened plate with random size. In the present paper, we investigated several kinds of perforated stiffened model from actual ship and then was performed finite element series analysis varying the cutout ratio, web height, thickness and type of cross-section using commercial FEA program(ANSYS) under compressive load.

Development of Ultimate Strength Design Formula considering Buckling under Longitudinal and Transverse Axial Compressive Load (종횡방향 압축하중을 받는 유공판의 최종강도 설계식 개발)

  • Park Joo-Shin;Ko Jae-Yong;Lee Jun-Kyo
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.173-179
    • /
    • 2006
  • A number of perforated plates are utilized for the passage of the crew and the equipment, reducing weight and the arrangement of piping. Hull girders in double bottom and floor plates are the typical parts which have those plates in a ship structure, and the perforated plate is usually positioned at the place which has less loading without local strength problems. In the case of utilizing the plate inevitably at the place which has large strength, an opening of the plate has large effect on the buckling strength due to in-plane rigidity and ultimate strength. Therefore the assessments of the elastic buckling strength and the ultimate strength for the perforated plate are the essential requirements for determining the dimensions of the parts at the initial design stage. With above reason, a need of the reasonable assessments for the elastic buckling strength and the ultimate strength has evolved. The numerical series analysis with the consideration of the effect due to various aspect ratios and slenderness ratios were performed using finite element method in this research. Simple formulas for the design are also proposed from the above analysis.

A Study on the Ultimate Strength Behavior for Ship Perforated Stiffened Plate (선체 유공보강판의 최종강도 거동에 관한 연구)

  • Ko Jae-Yong;Lee Jun-Kyo;Park Joo-Shin;Bae Dong-Kyun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.141-146
    • /
    • 2005
  • Ship have cutout inner bottom and girder and floor etc. Ship's structure is used much, and structure strength must be situated, but establish new concept when high stress interacts sometimes fatally the area. There is no big problem usually by aim of weight reduction, a person and change of freight, piping etc. Because cutout's existence grow up in this place, and, elastic buckling strength by load causes large effect in ultimate strength. Therefore, stiffened perforated plate considering buckling strength and ultimate strength is one of important design criteria which must examine when decide structural concept at initial design. Therefore, and, reasonable buckling strength about perforated stiffened plate need to ultimate strength limited design . Calculated ultimate strength varied several web height and cutout's dimension, and thickness in this investigated data. Used program(ANSYS) applied F.E.A code based on finite element method.

  • PDF

The Microbiological Assessment and Identification of Food Utensils and Food Service Facilities in School (학교 급식설비 및 집기류의 미생물학적 위해요소 분석)

  • Hong, Seung-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.189-194
    • /
    • 2014
  • This study was conducted to evaluate microorganism contamination of food utensils and service facilities in school and to prevent hazards by food poisoning occurrence. As a result, the highest number of microorganism growth plate ($12.3{\pm}2.6$) was detected in total bacteria test plate, and also observed $10.3{\pm}3.9$ growth plates in Staphylococcus aureus test plate and $9.5{\pm}3.9$ growth plates in E. coli and coliform bacteria test plate. But we could detect to the lowest number of growth plates ($1.5{\pm}1.0$) in Vibrio test plate. We also assessed that floors were appeared to the highest microorganism contamination rate in food utensils and service facilities. Therefore, $4.5{\pm}0.6$ growth plates was detected in pre-operation floor and $4.3{\pm}1.0$ growth plates in floor. And high level of microorganism contamination also observed in tables as $3.3{\pm}1.0$ growth plates in cooking table and $3.0{\pm}0.0$ growth plates in dining table. The level of microorganism contamination of food utensils such as kitchen knife, cutting board, and food tray were lower than that in food service facilities. We analysed microorganism contamination according to purpose of use in kitchen knifes and cutting boards. The microorganism contamination rate in fish kitchen knife ($2.0{\pm}0.8$) and fish cutting board ($1.3{\pm}1.5$) were slightly higher than that of others purpose of use. As a result of microorganism identification, various strains of microorganism were contaminated in food service facilities and some strains could detected more than two times. Especially, Staphylococcus aureus was repeatedly identified in cooking table, trench, and kitchen knife. Bacillus cereus was identified in kitchen knife, and then Pseudomonas fluorescens and Pseudomonas aeruginosa were also detected in food utensils and service facilities as known to food spoilage microorganisms. Klebsiella pneumoniae was detected four times repeat, which widely distribute natural environment as normal bacterial flora but sometimes cause acute pneumonia. These results suggest that food utensils and service facilities are contaminated with not only major food poisoning microorganisms such as Staphylococcus aureus, but also food spoilage microorganisms. Taken together, strict personal hygiene control and efficient food service facilities management will be needed to enhance food safety in school feeding and to improve student health.

Analysis of a Car Fire Case Caused by the Overheating of a Diesel Particulate Filter (매연포집필터 과열로 발생한 디젤승용차화재 원인의 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.89-97
    • /
    • 2017
  • This study analyzed the case of diesel car fires that occurred while driving in a tunnel 5 days after maintenance at a car service center. The results of the investigation and analysis found that a large amount of white foreign matter adhered to the inside of the exhaust port and the insulating plate above the DPF (diesel particulate filter) installed in the middle of the exhaust pipe was melted and lost. In particular, the metal floor of the car above the DPF was molten and pierced, and the rubber mat placed on the metal floor was burnt. Moreover, while the exhaust pipe in front of the DPF showed no overheating mark, such a mark was observed in the exhaust pipe from the DPF to the exhaust port. Because these findings may appear only when the DPF is overheated and ignited, this car fire is believed to have been caused by internal overheating of the DPF. The car fire investigation of this study suggests that if white foreign matter is found in the inside of the exhaust port during a fire cause investigation of a diesel car, the cause of the fire should be determined by removing the DPF and examining the internal damage of the DPF.

A Submandibular Gland Mucocele Extending to the Skull Base (두개저까지 확장된 악하선 점액류)

  • Kim, Il-Kyu;Yang, Jung-Eun;Chang, Jae-Won;Ju, Sang-Hyun;Pyun, Young-Hun;Kim, Lucia
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.180-184
    • /
    • 2011
  • The mucocele is a mucus extravasation cyst arising from the salivary gland. Although it is a common?lesion of the minor salivary gland, it is uncommon when it originated from the submandibular gland. The ranula is a form of mucocele which specifically occurs in the floor of the mouth and the sublingual gland is generally accepted as the origin of ranula. They can be classified into two types based on extent: simple ranula are confined to the sublingual space and plunging ranula extend into the adjacent space. It is difficult to differentiate the submandibular gland mucocele from the plunging ranula because both of them can occupy the submandibular space. A 37-year old male visited our clinic with the chief complaint of left facial swelling. The patient's history revealed that he had suffered from a cystic lesion on the left side of the floor of the mouth 10 months previously. He supposed the cystic lesion had come from trauma at other dental clinics. Using CT and MRI, we diagnosed a simple ranula on the sublingual space and a submandibular gland mucocele. We then excised the mucocele with the submandibular gland by an extraoral approach and the sublingual gland by an intraoral approach under general anesthesia. We report a rare case of an enormous submandibular gland mucocele which extended into the pterygoid plate and parapharyngeal space with good surgical results.

Infraorbital nerve transpositioning into orbital floor: a modified technique to minimize nerve injury following zygomaticomaxillary complex fractures

  • Kotrashetti, Sharadindu Mahadevappa;Kale, Tejraj Pundalik;Bhandage, Supriya;Kumar, Anuj
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.74-77
    • /
    • 2015
  • Objectives: Transpositioning of the inferior alveolar nerve to prevent injury in lower jaw has been advocated for orthognathic, pre-prosthetic and for implant placement procedures. However, the concept of infra-orbital nerve repositioning in cases of mid-face fractures remains unexplored. The infraorbital nerve may be involved in trauma to the zygomatic complex which often results in sensory disturbance of the area innervated by it. Ten patients with infraorbital nerve entrapment were treated in similar way at our maxillofacial surgery centre. Materials and Methods: In this article we are reporting three cases of zygomatico-maxillary complex fracture in which intra-operative repositioning of infra-orbital nerve into the orbital floor was done. This was done to release the nerve from fractured segments and to reduce the postoperative neural complications, to gain better access to fracture site and ease in plate fixation. This procedure also decompresses the nerve which releases it off the soft tissue entrapment caused due to trauma and the organized clot at the fractured site. Results: There was no evidence of sensory disturbance during their three month follow-up in any of the patient. Conclusion: Infraorbital nerve transposition is very effective in preventing paresthesia in patients which fracture line involving the infraorbital nerve.

Analytical Study on Relationship Between Moment Transfer Efficiency of a Beam Web and Strain Concentration at Steel Moment Connections (철골 모멘트 접합부에서 웨브의 모멘트 전달효율과 변형도 집중과의 관계에 관한 해석적 연구)

  • Kim, Young Ju;Oh, Sang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.695-703
    • /
    • 2004
  • In this paper, the results of monotonic loading analysis with four steel models and one composite model were shown. The effect that moment transfer efficiency of a web and strain concentration at a steel beam-to-column connections was investigated. Analysis results showed that the moment transfer efficiency of the analytical model with box-column was poor when comparing to model with H-column due to out-of-plane deformation of the box-column flange. The presence of scallop, thin plate of box column and floor slabs was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of the steel beam-to-column connections. Analytical results were compared with experimental results based on previous test. As a result, the deformation capacity of connections with a box-column or a floor slab decreased due to the poor moment transfer efficiency and the strain concentration of beam flange in the vicinity of the steel beam-to-column connections based on the experimental data.