Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test (비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가)

  • Lee, Jae-Sub;In, Sung-Woo;Jung, Dam-I;Lee, Doo-Yong;Lee, Sang-Hyen;Cho, Bong-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof (지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구)

  • Jo, Ho-Hyeon;Kim, Jung-Min;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

Effect of Cold Forming Method on Drawability in Trunk Floor Panel (냉각성형공법이 트렁크 플로어 드로잉성에 미치는 영향)

  • Choi C. S.;Choi Y. C.;Park J. H.;Oh Y. K.;Lee J. W.;Lee H. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.10a
    • /
    • pp.113-119
    • /
    • 2000
  • This study is to investigate the effects of cold forming method with steel sheet of SCP3C to improve continuous productivity. Experiments were carried out in various working conditions, such as the number of stamping and the punch temperature. The effects of the punch temperature and the number of stamping on drawability of steel sheet of SCP3C as well as clearance and draw-in in tile number of stamping were examined and discussed. The cooled the punch and the die and the blankholder heated by stamping were achieved at continuous productivity and quality improvement. The optimum forming condition for drawing trunk floor panel of SCP3C is shown as the punch is cooled by coolant of $-5^{\circ}C$ and at the same time both the die and the blankholder are heated by stamping and frictional heat,

  • PDF

Equivalent Plate Model and Acoustic Power Radiation of the Corrugated Panel Structures for High Speed Train (고속전철용 주름판넬구조의 등가평판모델 및 방사소음)

  • 장준호;이상윤;홍성철;이우식
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.3
    • /
    • pp.26-35
    • /
    • 1999
  • The acoustic power reduction method can be used to design a quiet structure. To calculate the acoustic power radiated from a vibrating structure, the dynamic responses have to be determined. It is not easy to analyse the structure composed of the corrugated panels because of the structural complexity and the long analysing time. To make up for these defects, the equivalent orthotropic panel is presented. Also the acoustic power prediction method of the vibrating structures is proposed. As examples, the equivalent material properties of the corrugated plates are obtained and the acoustic powers of the floor structure are calculated at several frequency regions for the Korean High Speed Train.

  • PDF

A Study on the Systematic Housing Plan Presentation Using Visual Perception Theories -Focused on the Composition of Presentation Panel- (시지각이론을 이용한 주택설계 프리젠테이션 체계화에 관한 연구 -프리젠테이션 판넬 구성을 중심으로-)

  • 이화숙
    • Journal of the Korean housing association
    • /
    • v.12 no.2
    • /
    • pp.77-85
    • /
    • 2001
  • Along with the development of creative design ideas, how to effectively present design concepts is also an important consideration on housing plan process. This could consequently make it possible to automate presentations. In spite of such needs of presentations any significant efforts for the systematic design presentation have not been made yet. The research goals established in order to solve these problems are to develop structures of presentation and analyze the cases of it. This paper explains structures of housing plan presentations in two ways: the compositional elements of panel presentations and the relationships among the elements. The elements include a project title, a synopsis, design concepts, building layouts, floor plan1 and 2, longitudinal and latitudinal elevations, sections, projection and perspective views, and model photographs. Among various relationships among panel compositional elements this study uses relationships based on the Gestalt theory, the balance theory by Rudolf Arnheim and the optical array theory by Gibson. The relationships investigated on the basis of the visual perception theories include the relationships between compositional elements and background space, visual weight balance, horizontal and vertical balances, grouping, and visual layout patterns.

  • PDF

Design Analysis System for Dieface of Stamping Press Dies (스탬핑 프레스 금형 다이페이스 설계 해석 시스템)

  • 금영탁;정승훈;이완우;박성일;김준환
    • Transactions of Materials Processing
    • /
    • v.9 no.6
    • /
    • pp.567-573
    • /
    • 2000
  • An analysis system for evaluating the design of dieface of stamping press dies is developed. The die design analysis system interfaced with CATIA via universal or NASTRAN data format provides the design information such as binder-wrap, punch contact status, section length change ratio, wrinkle symptom etc., which are crucial in predicting the defects of initial shape of the sheet in the dieface design stage. The graphic post-processor of developed system which displays 3-dimensional shapes of tool and die and analysis results, helps the interpretation of design evaluation. The dieface design analysis system was tested in draw dies of front floor panel and quarter panel of auto-body in order to verify the usefulness and validity of the system The examples show that the developed system would be a good tool in evaluating dieface designs.

  • PDF

Quasi-Static Test of Precast Concrete Large Panel Subassemblage (P.C 대형판넬 부분구조물의 Quasi-Static 실험연구)

  • Choi, Jeong-Su;Lee, Han-Seon;Kim, U;Hong, Gap-Pyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.73-78
    • /
    • 1990
  • Large panel building systems are composed of vertical wall panels which support horizontal roof and floor panels to form a box like structure. The simplecity of the connections, which makes precast concrete economically viable, causes a lack of continuity in stiffness, strength and ductility. This precast concrete large panel systems typically have weak connection regions. Three types of 2-story full-scale precast concrete subassemblages were tested under reversed cyclic loading. The seismic resistance capacity and failure mode of each system are compared in connection with the characteristics of joint connection details.

  • PDF

Seismic Response Comparative Evaluation Study on Floor Isolation using LRB and FPS in Main Control Room of Nuclear Power Plant (LRB, FPS 지진격리시스템의 지진응답특성 비교연구)

  • Lee, Kyung-Jin;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2009
  • An experimental study was performed to evaluate seismic reduction performance and the applicability of 2-dimensional floor isolation system to the main control room of a nuclear power plant. A lead-rubber bearing (LRB) and a friction pendulum system (FPS) were designed and fabricated for a 2-dimensional floor isolation system. A partial experimental model of a main control room with the LRB and FPS was tested using a shaking table. The experimental model consisted of a control panel, a 2.5m${\times}$2.5m access floor, and four LRB and FPS. The artificial time histories based on the horizontal floor response spectrums (OBE, SSE) of the main control room were used as earthquake input signals. Compared to the non-isolated system, the seismic response of experimental models using a 2-dimensional floor isolation system showed considerable seismic reduction performance against an earthquake.