• 제목/요약/키워드: Floor Panel

검색결과 177건 처리시간 0.027초

기존온수온돌과 조립식 온수온돌의 전열특성에 관한 실험적 연구 (An Experimental Study on Heat Transmission Characteristics of the Conventional and Prefabricated Ondol)

  • 민정현;이충구;장문석
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.611-621
    • /
    • 1995
  • The objectives of this study are to find out and to analyze the heat transmission characteristics of the conventional and prefabricated Ondol systems. To compare the thermal characteristics of these Ondol, a real sized Ondol model is set in a chamber. Hot water whose temperature is varied from $45^{\circ}C$ to $60^{\circ}C$ with $5^{\circ}C$ interval is supplied to each Ondol system. At that time the temperature distribution of floor surface, the amount of supplied heat, the heat radiation aspect and the heat loss from the floor to the underground are measured and analyzed simultaneously. As a result, even if the supplied hot water temperature to the prefabricated Ondol panel is lower by about $5^{\circ}C$ than that of the conventional Ondol panel, the net radiant effect is same. Heat radiation efficiency of the prefabricated Ondol panel is over 5% better than that of the conventional Ondol panel. It takes 12 hours for the conventional Ondol and 45 minutes for the prefabricated Ondol, respectively to reach steady state.

  • PDF

Displacement-based design method for an energy-dissipation self-centering wall panel structure

  • Sisi Chao;Guanqi Lan;Hua Huang;Huiping Liu;Chenghua Li
    • Steel and Composite Structures
    • /
    • 제51권3호
    • /
    • pp.289-304
    • /
    • 2024
  • The seismic performance of traditional steel frame-shear wall structures was significantly improved by the application of self-centering steel-reinforced concrete (SRC) wall-panel structures in the steel frames. This novel resilience functionality can rapidly restore the structure after an earthquake. The presented steel frame with steel-reinforced concrete self-centering wall-panel structures (SF-SCW) was validated, indicating its excellent seismic performance. The seismic design method based on bear capacity cannot correctly predict the elastic-plastic performance of the structure, especially certain weak floors that might be caused by a major fracture. A four-level seismic performance index, including intact function, continued utilization, life safety, and near-collapse, was established to achieve the ideal failure mode. The seismic design method, based on structural displacement, was proposed by considering performance objectives of the different seismic action levels. The pushover analysis of a six-floor SF-SCW structure was carried out under the proposed design method and the results showed that this six-floor structure could achieve the predicted failure mode.

공동주택에서 완충재를 이용한 바닥충격음 저감 System 연구 (Investigating of a Floor-Impact Isolation System Using Damping Materials In Apartment Buildings)

  • 송희수;정영;정정호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.499-504
    • /
    • 2004
  • The purpose of this study is to investigate a investigating of a floor-impact isolation system using damping materials in apartment buildings. The stiffness elastic modulus(k) by puls impact forces were calculated loss factor by Hilbert transforms. It is absolved that natural frequency was moved floor shock-absorbing materials and the impact force was reduced by floor panel. The slab was constructed by damping materials. As towards a result, the system showed inverse A 45dB by heavy weight-impact noise and inverse A 52dB by light-impact noise. High frequencies impact-noise can be reduced by upgrading naturial frequency of vibration and noise in the system.

  • PDF

태양광 패널 설치를 고려한 건축 디자인 지침 개발 연구 (A Study on the Building Design Guideline Development Considering Photovoltaic Panel Installation)

  • 문창호
    • 대한건축학회연합논문집
    • /
    • 제21권4호
    • /
    • pp.139-146
    • /
    • 2019
  • The purpose of this study is to propose the building design guideline considering photovoltaic panel installation through the analysis of relevant guidelines from home and abroad in terms of building design and solar panel installation. Conclusions can be summarized as followings; Considerations in building design : selection of the site with high solar accessibility, avoidance of the shade from the adjacent building & trees, south facing orientation of solar panel in building design, removal of shade on the solar panel from the part of building itself, load consideration of solar panel & fixing materials, safe passage securement for solar system maintenance, and planning of piping and mechanical room for solar system. Considerations in solar panel installation : harmonizing of solar panel with surrounding environment, unity of solar panel orientation & slope, regular maintenance of solar system, (in case of flat roof installation) solar panel installation afloat over the roof, installation area within the roof floor, and lower than parapet height, (in case of sloped roof installation) solar panel installation parallel with the roof slope, ventilation space securement below the panel, installation area within the roof surface, and similar material installation in empty space.

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

냉각성형공법이 트렁크 플로어 드로잉성에 미치는 영향 (Effect of Cold Forming Method on Drawability Trunk Floor Panel)

  • 최치수;최이천;오영근;이정우;이항수
    • 소성∙가공
    • /
    • 제10권2호
    • /
    • pp.123-129
    • /
    • 2001
  • This study is to investigate the effects of cold forming method with steel sheet of SCP3C to improve continuous productivity. Experiments were carried out in various working conditions, such as the number of stamping and the punch temperature. The effects of the punch temperature and the number of stamping on drawability of steel sheet of SCP3C as well as clearance and draw-in in the number of stamping were examined and discussed. More improvement of continuous productivity in case of cold stamping rather than by conventional stamping at room temperature is obtained. The optimum forming condition for drawing trunk floor panel of SCP3C is shown as the punch is cooled by coolant of $-5^{\circ}C$ and at the same time both the die and the blankholder are heated by stamping and frictional heat.

  • PDF

바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구 (A study on the comfort thermal environment by the Draft in floor panel heating system)

  • 이경희
    • 한국주거학회논문집
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

Optimal design of the floor panel for an automotive platform under uncertainty of the vehicle length

  • Lahijani, Abdolah Tavakoli;Shojaeefard, M.H.;Khalkhali, Abolfazl
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.91-98
    • /
    • 2018
  • Length of a vehicle is an important variation to generate different variants of an automotive platform. This parameter is usually adjusted by embedding dimensional flexibility into different components of the Body in White (BIW) including the floor pan. Due to future uncertainties, it is not necessarily possible to define certain values of wheelbase for the future products of a platform. This work is performed to add flexibility into the design process of a length-variable floor pan. By means of this analysis, the cost and time consuming process of optimization is not necessary to be performed for designing the different variants of a product family. Stiffness and mass of the floor pan are two important functional requirements of this component which directly affect the occupant comfort, dynamic characteristics, fuel economy and environmental protection of the vehicle. A combination of Genetic algorithm, GMDH-type of artificial neural networks and TOPSIS methods is used to optimally design the floor pan associated with arbitrary length of the variant in the defined system range. The correlation between the optimal results shows that for a constant mass of the floor pan, the first natural frequency decreases by increasing the length of this component.

Vibration performance characteristics of a long-span and light-weight concrete floor under human-induced loads

  • Cao, Liang;Liu, Jiepeng;Zhou, Xuhong;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제65권3호
    • /
    • pp.349-357
    • /
    • 2018
  • An extensive research was undertaken to study the vibration serviceability of a long-span and light-weight floor subjected to human loading experimentally and numerically. Specifically, heel-drop test was first conducted to capture the floor's natural frequencies and damping ratios, followed by jumping and running tests to obtain the acceleration responses. In addition, numerical simulations considering walking excitation were performed to further evaluate the vibration performance of a multi-panel floor under different loading cases and walking rates. The floor is found to have a high frequency (11.67 Hz) and a low damping ratio (2.32%). The comparison of the test results with the published data from the 1997 AISC Design Guide 11 indicates that the floor exhibits satisfactory vibration perceptibility overall. The study results show that the peak acceleration is affected by the walking path, walking rate, and adjacent structure. A simpler loading case may be considered in design in place of a more complex one.

잠열저장패널이용 바닥난방공간의 실내온도분포에 관한 연구 (Indoor Air Temperature Distribution in a Floor Heating Space with PCM Panels)

  • 조수;손장열
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.59-71
    • /
    • 1992
  • 본 연구는 주거용건물에서의 난방용에너지 소비량절감 및 실내환경의 쾌적도 향상을 목적으로, 잠열재 용기의 축열 및 방열특성을 파악한 후, 잠열저장패널을 이용한 바닥난방공간의 실내온도분포를 분석하였다. 잠열저장패널의 특성을 구명하기 위해서는 패널의 가열시간에 따른 잠열재의 융해 및 응고특성에 대해 실험 분석하고 실험건물을 이용하여 잠열저장패널을 설치한 실내공간의 온도분포에 대해 실험 분석하였다.

  • PDF