• Title/Summary/Keyword: Floor Device

Search Result 142, Processing Time 0.028 seconds

Seismic test of modal control with direct output feedback for building structures

  • Lu, Lyan-Ywan
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.633-656
    • /
    • 2001
  • In this paper, modal control with direct output feedback is formulated in a systematic manner for easy implementation. Its application to the seismic protection of structural systems is verified by a shaking table test, which involves a full-scale building model and an active bracing system as the control device. Two modal control cases, namely, one full-state feedback and one direct output feedback control were tested and compared. The experimental result shows that in mitigating the seismic response of building structures, modal control with direct output feedback can be as effective and efficient as that with full-state feedback control. For practical concerns, the control performance of the proposed method in the presence of sensor noise and stiffness modeling error was also investigated. The numerical result shows that although the control force may be increased, the maximum floor displacements of the controlled structure are very insensitive to sensor noise and modeling error.

A Study on Domestic Standardization Environments for CIM (Part. 1) (CIM 관련 국내 표준화환경에 대한 조사연구(제1보))

  • Lee, Ho-Gil;Gang, In-Pil;Ko, K.W.;Suh, H.W.;Yoo, S.B.;Jeong, Gyeong-Ryeol;Kim, Hong-Seok;Kim, Yong-Seok;Park, Hong-Seong;Gwon, Uk-Hyeon
    • IE interfaces
    • /
    • v.8 no.3
    • /
    • pp.111-121
    • /
    • 1995
  • 본 논문에서는 효율적인 CIM 구축을 위해 필요로 하는 표준항목과, 이에 관련된 국제표준동향, 국내의 표준화 여건에 대해 요약하고, 설문조사를 통한 국내전문가 의견 수렴결과를 취합하였다. 설문의 조사내용은 CIM이 아직 보편화도지 않은 상항을 고려하여 FA기기 및 요소기술을 중심으로 작성하였으나, 설문결과의 분석은 시스템통합이란 관점에서 분석하여 국가적으로 시급히 추진해야 할 표준항목을 도출하였으며, 국내 여건을 고려한 표준화 추진방안을 고찰하였다.

  • PDF

Model House System Using Virtual Reality (가상현실을 활용한 모델하우스 시스템)

  • Kim, Seung geun;Kim, Dong hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.92-93
    • /
    • 2017
  • Before showing the real house, generally a broker shows the blue print of the house to a customer who looks for houes to reside. However, it is difficult to for the customer to realize the house in detail by the blue print. To solve this problem, meet develop model house system using the virtual reality technology. The develop system shows the blue print of the house in 3D on the android device and make it possible for the user to move in the house projected virtually by using controllers.

  • PDF

A look at rooftop waterproofing methods that combine a circular adhesive insulated composite duplex exposure repellent with a airvent (원형 접착 절연형의 복합 복층형 노출 방수제와 탈기관을 결합한 옥상 방수 공법에 관한 고찰)

  • KIM, Yeong-Seok;JEON, Sang-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.236-237
    • /
    • 2021
  • In the waterproofing of the rooftop of reinforced concrete buildings, it is difficult to solve perfectly according to the proficiency of waterproofing materials, methods, and mechanics. Therefore, this study applies a Tricot Fabric Mesh to the behavior of the bottom concrete. In addition, it responds to the behavior of the concrete cracking, and the waterproofing and protective layer has developed a method to provide convenience for rooftop floor use by adhesion between the base and the waterproof layer with the use of high viscosity urethane to effectively move the surface deformation and surface vapor and install a airvent device on the wall.

  • PDF

A Study for Decrease Accident from Falls at the Construction Sites - Focused on Under 2nd Floor (건설현장의 추락재해 감소방안을 위한 연구 - 2개층 이하 높이 추락재해 감소 방안)

  • Park, Jun-Ky;Shin, Seung-Ha;Lee, Jung-Won;Kim, Kyung-Hwan
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.918-921
    • /
    • 2008
  • There are various accident at the Construction site like fall, electric shock, roll over, clash, fire, body cutting. By the way, falls are the most causes accidents. So, the best way of decreasing Construction accidents is decreasing falls. Already, there are many studies about falls accidents, but those studies were pointed out unrealistic because falls accidents are increasing. For that reason, this study look for more concrete device. In this study, grasp the cause of falls accident from 2007 to 2008. 06. 30. And then, stand on this factor I set my face to look for the causes of falls accident. This access means will drive to remove core causes, and then that means will decrease the falls accidents. Moreover that means will contribute decreasing the hole construction accidents.

  • PDF

Case Study on Characteristics of the Bedroom Environment in Korean Nursing Homes

  • Kim, Dae-Nyun;Yoon, Young-Sun;Moon, Jae-Ho;Byun, Hea-Ryung;Chung, Mi-Ryum;Hong, Min-Jung
    • International Journal of Human Ecology
    • /
    • v.8 no.2
    • /
    • pp.29-46
    • /
    • 2007
  • The purpose of this study was to analyze characteristics of the bedroom environment of nursing homes for the elderly in Korea. Field case research was performed using a structured checklist and measurements, from Oct. 28th to Dec. 2nd, 2006. Collected data were analyzed for cognitive efficiency, privacy, safety, supportiveness and amenity. Based on nursing homes for the elderly nationwide (Ministry of Health and Welfare, 2006), we choose 43 facilities in which Seoul and six megalopolis areas that had answered our questionnaire in 2006. We then narrowed the list to 14 facilities, balanced them in terms of regional population. The contents of investigation consisted of eight categories: that general characteristics of the bedrooms (including number of residents per room, using a bed or floor mat, the size and shape of the chamber, space for wheelchair turning, signage), door of bedroom (including door, doorknob, door sill/level difference), windows in the bedroom(including type of window, window sill height, window treatment, window safety device/shape, view/daylight), furniture (including personal furniture and lock), finishes (material, character and color of wall, floor, ceiling), lighting (including types of lighting, night lighting, switch), bathroom in the bedroom (including signage, door size/type, doorknob shape, height of the washbowl, size of toilet bowl, handrail, finishes), and other facilities (including outlet and handrails).

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

A Study on the Improvement Direction through the Present Status of Nursing Home - Focus on the Nursing Home in Chungcheongbuk-do - (노인요양시설의 건축현황 및 개선방향에 관한 연구 - 충청북도 노인요양시설을 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • Recently, the long-term care insurance for the elderly was carried out according to the elderly is increased rapidly and the formation of sympathy that a nation and society try commonly to share health and welfare promotion of the elderly. The purpose of this study is to analyze the present status of nursing home after that the long-term care insurance is enforced in chungcheongbuk-do and to utilize as basic data. The study limited its survey to those facilities that refer to the Ministry of Health and Welfare data, that had the capacity of more than 50 people. The result are as followings. Firstly, most of the nursing home were located on the outskirts of the city. But it must be constructed in the city center if the recent deinstitutionalization trend is reflected. Secondly, notwithstanding the provisions of the Elderly Welfare Law, if the Livability and amenity are considered, the plan of a single or a twin room is needed. The ondol(溫突) system bedroom for the safety of the elderly had to be planned and for the color planning of a bedroom, a heating, the furniture, the form of a door, corridors, etc. should be partly improved. The fastener in which it is appropriate for the main exit, a stair, an elevator, the lighting device, and etc. is needed and the installation of a wandering path for the dementia patient and etc. is required. Thirdly, most of the dining room arranged on the first floor but it is not nearly used and it used for employee or the other use. Therefore, we have to consider the system in which it can deliver the meal to a bedroom. If the smell of the elderly and etc. is considered, the sufficient height of the floor should be reflected for the ventilation equipment. Lastly, The improvement of the existing law are required.

Retrofitting of vulnerable RC structures by base isolation technique

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Ahmmad, Rasel;Darain, Kh. Mahfuz ud
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.603-623
    • /
    • 2015
  • The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.