• Title/Summary/Keyword: Floating Building

Search Result 129, Processing Time 0.022 seconds

A Study on Present Condition and Spatial Organization of Domestic Marina Club to Design Leisure Floating Architecture (레저용 플로팅건축물 설계를 위한 국내 마리나클럽 현황 및 공간구성에 관한 연구)

  • Pak, Sung-Sine
    • Journal of Navigation and Port Research
    • /
    • v.36 no.3
    • /
    • pp.253-259
    • /
    • 2012
  • Marina and marina clubs are the essential structures to meet increasing marin tourism and marin leisure sports demand. According to the domestic situation, marina and marina clubs are divided into 6 types such as small sports type, small complex type, midium sports type, midium complex type, large sports type, large complex type. As a result of analysis of domestic three marina clubs, averagely marina facilities take 21% and commercial facilities take 79% of total space. In the short term, marina club should be designed focusing on complex program. Marina club will be for long-term transformed into marin leisure sports program. Additionally, it is certain that floating marina club is an architecture to have water-friendly space and to maximize marin tourism and marin leisure sports.

Heat of Hydration and Thermal Crack Control for Floating Concrete Mass Foundation (부상식 매스콘크리트 기초의 수화열 관리 및 온도균열 제어)

  • Rhee, In-Kyu;Kim, Kwang-Don;Kim, Tae-Ook;Lee, Jun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.156-164
    • /
    • 2010
  • A total of 6 stepwise constructions were made for building the floating mass concrete foundation. The optimal curing strategies and specialized construction guidelines were adoptively extracted from the 1.5m cube mock-up test prior to the main concrete work. Two different thermal crack index(TCI) calculations from current construction manual exhibit relatively low values as comparing the measured temperature data. This implies that the hydration-induced cracking could be developed in parts of concrete mass. However, the controversial phenomenons in reality were observed. No significant surface cracks are detected at the successive construction stages. Thereby, this paper raises the question regarding on the existence of characteristic length with varying size and shape of a target specimen which are missing in the current construction manual. The isothermal core area and high thermal gradient area in the edge volume should be identified and be introduced to TCI calculation for the purpose of an accuracy.

Formative Expressions by Artificial Light applied to Office Building Lobbies (현대 오피스 로비공간에서 빛의 조형적 표현 특성에 관한 연구)

  • Jeong, Soo-Ryun
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.2
    • /
    • pp.41-49
    • /
    • 2009
  • Contemporary design environment is formed with image-centered trend based on pluralism. In this point of view, enterprises' building lobbies are public places containing the equivocal meaning, actively utilizing light as a design element to express the image of enterprises' identifications. Light is an immaterial entity having unlimited possibilities and potentials on space. It also acts as media to activate spaces and create new images in connection with formative elements of space. This study is to figure out how lightings are expressed and affected the formative characteristics of office lobby spaces and activate the specific characteristics of spaces. As a result, we drew conclusions as follows. First, as state-of-the-art technology and media are introduced, light is expressed on spaces as floating, direction, rhythm, silhouette, metaphor and allusion, sense of depth and volume. Second, expressive aspects of light in lobby space are embodiment of light, substantiation of immateriality, standing of materiality from the perspective of spatial aesthetics, and distortion/transformation of shape, pluralism phenomena of space from the perspective of spatial structure. In this way, light on building lobbies which are greatly required design differentiation strategy, specializes space and also integrates all the designs as not only a functional element but also a mental, psychological, formative element. Consequently, light on lobby spaces induces communication between spaces and users, makes formative value of existence in itself, and presents the characteristics of differentiated enterprises' identities.

The Structural Engineering Design And Construction Of The Tallest Building In Europe Lakhta Center, St. Petersburg. Russia

  • Abdelrazaq, Ahmad;Travush, Vladimir;Shakhvorostov, Alexey;Timofeevich, Alexander;Desyatkin, Mikhail;Jung, Hyungil
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.3
    • /
    • pp.283-300
    • /
    • 2020
  • The Lakhta Center is a Multifunction Complex Development (MFCD) consisting of 1) an 86 story office tower rising 462 m above the ground to provide high-end offices for Gazprom Neft and Gazprom Group affiliates 2) a Multi-Function Building (MFB) that includes, a scientific/educational center, a sport center, a children's technopark, a planetarium, a multi-transformable hall, an exhibition center, shops, restaurants, and other public facilities 3) a Stylobate 4) "The Arch, which forms the main entrance to the tower, restaurants, and cafes 5) underground parking and 6) a wide range of large public plazas. While each of the MFCD buildings is technically challenging in its own right, the focus of the paper is to present the development and integration of the structural and foundation systems of the bowed, tapered, and twisted shape of the tower into the fabric of the tallest Tower in Europe.

Evaluating Spatiality of Green-House Gas Emission in Building Site ("대" 지목에 의거한 온실가스 분포의 공간성 평가)

  • Kim, Jun-Hyun;Um, Jung-Sup
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.06a
    • /
    • pp.94-102
    • /
    • 2010
  • These days the land category is the most specific basis of legal for land use or land use form that is determined by the main use of land. Even if same land building site, it is used very various like a detached house, a row house, a multiplex house, a villa, an apartment, a mixed-use Apartments, commercial building, fallow land etc. There is a need of variety analysis in order to apply greenhouse gas emission or statistics assessment for standard of classification. Therefore, This study measured carbon dioxide by for different government agencies of maps by land use time, season, elevation, space, area of floating population. As a result, The emission characteristic was high l.78 times, on average of l.35 times in winter compared with summer, when the temperatures increased 11C, the carbon dioxide is 22ppm high in the afternoon, A commercial building is high 4.04 times compare with detached house.

  • PDF

A Study on the Effect of Photocatalyst Coating to Improve the Indoor Air Quality in Buildings (건축물 실내 공기질 향상을 위한 광촉매 코팅 효과에 관한 연구)

  • Park, Hyeon-Ku;Kim, Jong-Ho;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.150-157
    • /
    • 2006
  • Sick Building Syndrome (SBS) is an illness symptom such as irritation of eyes, skin eruption and vomit ing in newly constructed buildings. It is mainly due to the harmful gases from the materials installed in building such as Volatile Organic Compounds (VOCs), Semivolatile Organic Compounds (SVOCs), floating bacteria, fungi, fungal spores and viruses, human bioeffluents in many modem buildings. The general ways to improve the Indoor Air Quality (IAQ) are ventilating, utilizing eco-material without harmful gases and reducing or removing harmful gases through additional treatment to the building materials. This study aimed to improve the Indoor Air Quality(IAQ) by applying surface coating on the building materials and to make safe living environments through the analysis of air quality before and after surface coating treatment in buildings.

Building a Robust 3D Statistical Shape Model of the Mandible (견고한 3차원 하악골 통계 형상 모델 생성)

  • Yoo, Ji-Hyun;Hong, Helen
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.2
    • /
    • pp.118-127
    • /
    • 2008
  • In this paper, we propose a method for construction of robust 3D statistical shape model in the mandible CT datasets. Our method consists of following four steps. First, we decompose a 3D input shape Into patches. Second, to generate a corresponding shape of a floating shape, all shapes in the training set are parameterized onto a disk similar to the patch topology. Third, we generate the corresponding shape by one-to-one mapping between the reference and the floating shapes. We solve the problem failed to generate the corresponding points near the patch boundary Finally, the corresponding shapes are aligned with the reference shape. Then statistical shape model is generated by principle component analysis. To evaluate the accuracy of our 3D statistical shape model of the mandible, we perform visual inspection and similarity measure using average distance difference between the floating and the corresponding shapes. In addition, we measure the compactness of statistical shape model using the modes of variation. Experimental results show that our 3D statistical shape model generated by the mandible CT datasets with various characteristics has a high similarity between the floating and corresponding shapes and is represented by the small number of modes.

Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P (F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책)

  • Jeong, Jeong-Ho;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeon, Jin-Yong;Jo, A-Hyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.