• Title/Summary/Keyword: Flip Angle

Search Result 75, Processing Time 0.027 seconds

Analysis of Specific Absorption Rate in Magnetic Resonance Imaging (자기공명영상장치에서 전자파흡수율 분석)

  • Han, Jae-Bok;Hong, Seong-Hun;Choi, Nam-Gil;Seong, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.308-313
    • /
    • 2013
  • In this paper, we measured specific absorption rate (SAR) using characteristic variables such as flip angle, repetition time (TR) and echo time (TE) at magnetic resonance imaging. The subject was applied to same scan technique from body weight 10 kg to 90 kg, were measured for the average SAR and the peak SAR values according to the change of parameter. SAR with different body weight levels was not seen a significant change at TE but it increased in the larger flip angle and the shorter TR. SAR value was within the limits of human head acceptable standard and SNR in segmental body weights was not proportional to the increase of body weights. In conclusion, this study can be helpful for diagnosis by using appropriate parameters which obtained the various contrast and SNR.

Optimal Flip Angle for T2-Weighted Effect in Micro 4.7T MRI SE Sequence (마이크로 4.7T MRI SE Sequence에서 T2강조효과를 위한 최적의 Flip Angle)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.113-117
    • /
    • 2019
  • The purpose of this study was to investigate the FA value which can produce the best T2-weighted images by measuring the signal intensity and noise according to the FA value change in the brain image and the abdominal image of the mouse using micro-MRI. Brain imaging and abdominal imaging of BALB / C mice weighing 20g were performed using 4.7T (Bruker BioSpin MRI GmbH) micro-MRI equipment, Turbo RARE-T2 (spin echo-T2) images were scanned at TR 3500 msec and TE 36 msec. The changes of the FA values were $60^{\circ}$, $80^{\circ}$, $100^{\circ}$, $120^{\circ}$, $140^{\circ}$, $160^{\circ}$ and $180^{\circ}$. We measured signal intensity according to FA values of ventricle and thalamus in brain imaging, The signal intensity of kidney and muscle around the kidney was measured in abdominal images. To obtain SNR and CNR, we measured the background signals of two different parts, not the tissue. In the brain (thalamus) image, the signal intensity of FA $100^{\circ}$ was 7,433 and SNR (6.49) was the highest. In the abdominal (kidney) image, the signal intensity was highest at 16,523 when FA was $120^{\circ}$, and the highest SNR was 8.54 when FA was $140^{\circ}$. The CNR value of the brain image was 1.38 at FA $60^{\circ}$ and gradually increased to 8.29 at FA $180^{\circ}$. The CNR value of the muscle adjacent to the kidney gradually increased from 2.36 when the FA value was $60^{\circ}$ and the highest value was 4,57 at the FA value $180^{\circ}$.

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

Effect of the Tolerance Parameters of the Horn on the Vibration of the Thermosonic Transverse Bonding Flip Chip System (횡 방향 플립 칩 초음파 접합 시 혼의 공차변수가 시스템의 진동에 미치는 영향)

  • Jung, Ha-Kyu;Kwon, Won-Tae;Yoon, Byung-Ok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.116-121
    • /
    • 2009
  • Thermosonic flip chip bonding is an important technology for the electronic packaging due to its simplicity, cost effectiveness and clean and dry process. Mechanical properties of the horn and the shank, such as the natural frequency and the amplitude, have a great effect on the bonding capability of the transverse flip chip bonding system. In this research, two kinds of study are performed. The first is the new design of the clamp and the second is the effect of tolerance parameters to the performance of the system. The clamp with a bent shape is newly designed to hold the nodal point of the flip chip. The second is the effect of the design parameters on the vibration amplitude and planarity at the end of the shank. The variation of the tolerance parameters changes the amplitude and the frequency of the vibration of the shank. They, in turn, have an effect on the quantity of the plastic deformation of the gold ball bump, which determined the quality of the flip chip bonding. The tolerance parameters that give the great effect on the amplitude of the shank are determined using Taguchi's method. Error of set-up angle, the length and diameter of horn and error of the length of the shank are determined to be the parameters that have peat effect on the amplitude of the system.

The effect of aerodynamic characteristics on the insect wing tip trajectory in hovering flight (정지 비행에서의 곤충 날개 궤적에 따른 공기역학적 특성)

  • Cho, Hun-Kee;Joo, Won-Gu
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1441-1445
    • /
    • 2008
  • Insect flight is adapted to cope with each circumstance by controlling a variety of the parameters of wing motion in nature. Many researchers have struggled to solve the fundamental concept of insect flight, but it has not been solved yet clearly. In this study, to find the most effective flapping wing kinematics, we conducted to analyze CFD data on fixing some of the optimal parameters of wing motion such as stoke amplitude, flip duration and wing rotation type and then controlled the deviation angle by fabricating wing tip motion. Although all patterns have the similar value of lift coefficient and drag coefficient, pattern A(pear-shape type) indicates the highest lift coefficient and pattern H(pear-shape type) has the lowest lift coefficient among four wing tip motions and three deviation angles. This result suggest that the lift and drag coefficient depends on the angle of attack and the deviation angle combined, and it could be explained by delayed stall effect.

  • PDF

Manufacturing of PAR Illumination Using COB Line Type LEDs (COB Line형 LED를 사용한 PAR 조명의 제작)

  • Youn, Gap-Suck;Yoo, Kyung-Sun;Lee, Chang-Soo;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.448-454
    • /
    • 2015
  • In this paper, the band structural design that is typically in a line was arranged in a ring shape, so as to configure the high power LED lighting in such a way as to form a concentrated light distribution angle of less than 15 degrees. The parabolic aluminized reflector PAR38 that facilitates design using area and the area of the optical system to the same extent, applied a multiple light-source condenser lens optical system for the control of integration. The LED used here implemented a single linear light source using ans LED module with ans LED, flip-chip chip-scale package. The optical system was designed based on the energy star standard.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Flow Characteristics and Filling Time Estimation for Underfill Process (언더필 공정에 대한 유동 특성과 침투 시간 예측 연구)

  • Sim, Hyung-Sub;Lee, Seong-Hyuk;Kim, Jong-Min;Shin, Young-Eui
    • Journal of Welding and Joining
    • /
    • v.25 no.3
    • /
    • pp.45-50
    • /
    • 2007
  • The present study is devoted to investigate the transient flow and to estimate the filling time fur underfill process by using the numerical model established on the fluid momentum equation. For optimization of the design and selection of process parameters, this study extensively presents an estimation of the filling time in the view points of some important factors related to underfill materials and flip-chip geometry. From the results, we conclude that the filling time changes with respect to the under fill materials because of different viscosity, surface tension coefficient and contact angle. It reveals that, as the gap height increases, the filling time decreases substantially, and goes to the saturated values.

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF