• Title/Summary/Keyword: Flexor digitorum profundus tendon

Search Result 13, Processing Time 0.021 seconds

Tenorrhaphy using Suture anchor in delayed rupture of the flexor digitorum profundus tendon in the distal phalanx - A case report - (Suture anchor를 이용하여 건봉합술을 시행한 심수지 굴건 지연파열 - 증례 보고 -)

  • Kim, Seong Wan;Yi, Seung Rim;Yang, Bo Kyu;Kim, Woo;Lee, Sung Yup
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.117-120
    • /
    • 2011
  • Avulsion rupture of the flexor digitorum profundus tendon at the distal phalanx is a rare injury. It usually occurs during extension of the DIP joint, while the flexor digitorum profundus tendon is contracted, or when strong extension force is applied, to the distal phalanx. We experienced a patient, combat policeman who had avulsion rupture of flexor digitorum profundus tendon at the distal phalanx after 2 days of combat exercise. Here, we would like to report unusual case of rare tendon injury with studies from other papers.

  • PDF

Intratendinous Fibroma with a Flexor Profundus Tendon Tear in the Finger of an Adolescent Baseball Player: A Case Report (야구 선수의 수지에서 심수지굴곡건 파열을 동반한 건내 섬유종: 증례 보고)

  • Kim, Kyu Jin;Lee, Jae Hoon
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.262-266
    • /
    • 2018
  • Flexor digitorum profundus (FDP) tears in adolescents appear as avulsion tears in the FDP tendon, whereas longitudinal tears are very rare. Moreover, there has been only one reported case of intratendinous fibroma occurring in the flexor tendon of a finger. A longitudinal tear of the flexor profundus tendon associated with an intratendinous fibroma has not been previously reported. We report one case of a longitudinal partial tear accompanied by an intratendinous fibroma at the FDP tendon of the left middle finger after a hyperextension injury caused by the impact of a baseball. Given the rarity of longitudinal flexor tendon tears in adolescents, in such cases, the possibility of an underlying pathology should be considered.

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • The Journal of Korean Medicine
    • /
    • v.26 no.1 s.61
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

An accessory muscle of flexor digitorum profundus with bipennate first lumbrical: a unique variation of clinical significance

  • Rohini Motwani;Ariyanachi Kaliappan;Mrudula Chandrupatla
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.150-154
    • /
    • 2023
  • During the deep dissection of the front of the forearm, an anomalous accessory muscle in relation to the flexor digitorum profundus (FDP) muscle was observed in the right forearm. The accessory muscle consisted of a spindle-shaped muscle belly with a long tendon underneath the flexor pollicis longus muscle. When followed distally, the accessory muscle tendon was found lateral to the FDP tendon for the index finger and entered the palm deep to the flexor retinaculum. In the palm, we encountered the first lumbrical muscle as a bipennate muscle taking origin from the adjacent sides of the middle of the tendons of FDP and accessory muscle tendon. After giving origin to first lumbrical muscle, the accessory muscle got merged with the tendon of FDP for index finger. Understanding this kind of variation is required for radiologists and hand surgeons for diagnostic purposes and while performing corrective surgical procedures.

Flexor Tendon Rupture Secondary to Gout

  • Jeremy V. Lynn;Amy L. Strong;Kevin C. Chung
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.492-495
    • /
    • 2023
  • Extra-articular deposition of monosodium urate crystals is a widely recognized manifestation of gout. However, gouty infiltration of flexor tendons in the hand resulting in tendon rupture is exceedingly rare. This case report highlights a patient with gouty infiltration of flexor tendons in the right middle finger resulting in rupture of both the flexor digitorum profundus and flexor digitorum superficialis. Given the extent of gouty infiltration and need for pulley reconstruction, the patient was treated with two-stage flexor tendon reconstruction. Febuxostat was prescribed preoperatively to limit further deposition of monosodium urate crystals and continued postoperatively to maximize the potential for long-lasting results. Prednisone was prescribed between the first- and second-stage operations to prevent a gout flare while the silicone rod was in place. In summary, tendon rupture secondary to gouty infiltration is the most likely diagnosis in patients with a history of gout presenting with tendon insufficiency.

Study on the Anatomical Pericardium Meridian Muscle in Human (수궐음 심포경근의 해부학적 고찰)

  • Park, Kyoung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.22 no.1
    • /
    • pp.67-74
    • /
    • 2005
  • Objectives : This study was carried to identify the component of the Pericardium Meridian Muscle in human. Methods : The regional muscle group was divided into outer, middle, and inner layer. The inner part of body surface were opened widely to demonstrate muscles, nerve, blood vessels and to expose the inner structure of the Pericardium Meridian Muscle in the order of layers. Results We obtained the results as follows; He Perfcardium Meridian Muscle composed of the muscles, nerves and blood vessels. In human anatomy, it is present the difference between terms (that is, nerves or blood vessels which control the muscle of the Pericardium Meridian Muscle and those which pass near by the Pericardium Meridian Muscle). The inner composition of the Pericardium Meridian Muscle in human is as follows ; 1) Muscle P-1 : pectoralis major and minor muscles, intercostalis muscle(m.) P-2 : space between biceps brachialis m. heads. P-3 : tendon of biceps brachialis and brachialis m. P-4 : space between flexor carpi radialis m. and palmaris longus m. tendon(tend.), flexor digitorum superficialis m., flexor digitorum profundus m. P-5 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum superficialis m., flexor digitorum profundus m. tend. P-6 : space between flexor carpi radialis m. tend. and palmaris longus m. tend., flexor digitorum profundus m. tend., pronator quadratus m. H-7 : palmar carpal ligament, flexor retinaculum, radiad of flexor digitorum superficialis m. tend., ulnad of flexor pollicis longus tend. radiad of flexor digitorum profundus m. tend. H-8 : palmar carpal ligament, space between flexor digitorum superficialis m. tends., adductor follicis n., palmar interosseous m. H-9 : radiad of extensor tend. insertion. 2) Blood vessel P-1 : lateral cutaneous branch of 4th. intercostal artery, pectoral br. of Ihoracoacrornial art., 4th. intercostal artery(art) P-3 : intermediate basilic vein(v.), brachial art. P4 : intermediate antebrachial v., anterior interosseous art. P-5 : intermediate antebrarhial v., anterior interosseous art. P-6 : intermediate antebrachial v., anterior interosseous art. P-7 : intermediate antebrachial v., palmar carpal br. of radial art., anterior interosseous art. P-8 : superficial palmar arterial arch, palmar metacarpal art. P-9 : dorsal br. of palmar digital art. 3) Nerve P-1 : lateral cutaneous branch of 4th. intercostal nerve, medial pectoral nerve, 4th. intercostal nerve(n.) P-2 : lateral antebrachial cutaneous n. P-3 : medial antebrachial cutaneous n., median n. musrulocutaneous n. P-4 : medial antebrachial cutaneous n., anterior interosseous n. median n. P-5 : median n., anterior interosseous n. P-6 : median n., anterior interosseous n. P-7 : palmar br. of median n., median n., anterior interosseous n. P-8 : palmar br. of median n., palmar digital br. of median n., br. of median n., deep br. of ulnar n. P-9 : dorsal br. of palmar digital branch of median n. Conclusions : This study shows some differences from already established study on meridian Muscle.

  • PDF

Loop Suture Technique for Flexor Digitorum Profundus Tendon Repair in the Insertion Site (고리 봉합법을 이용한 심부 수지 굴건 종지부에서의 건봉합)

  • Lee, Kyu-Cheol;Lee, Dong-Chul;Kim, Jin-Soo;Ki, Sae-Hwi;Roh, Si-Young;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.650-658
    • /
    • 2010
  • Purpose: In the case of repair for far distal parts of FDP (Flexor digitorum profundus) division, the method of either pull-out suture or fixation of tendon to the distal phalanx is preferred. In this paper, the results of a modified loop suture technique used for the complete division of FDP from both zone 1a and distal parts of zone 1b in Moiemen classification are presented. Methods: From July 2006 to July 2009, the modified loop suture technique was used for the 10 cases of FDP in complete division from zone 1a and distal parts of zone 1b, especially where insertion sites were less than 1 cm apart from a tendon of a stump. In a suture technique, a loop is applied to each distal and proximal parts of tendon respectively. Core suture of 2-strand and epitendinous suture are done with PDS 4-0. Out of 10 patients, the study was done on 6 patients who were available for the followup. The average age of the patients was 49.1 years (in the range from 26 to 67). 5 males and 1 female patients were involved in this study. There were 3 cases with zone 1a and distal parts of zone 1b. The average distance to the distal tendon end was 0.6 cm. There were 5 cases underwent microsurgical repair where both artery and nerve divided. One case of only tendon displacement was presented. The dorsal protective splint was kept for 5 weeks on average. The results of the following tests were measured: active & passive range of motion, grip strength test, key pinch and pulp pinch test. Results: The follow-up period on average was 11 months, in the range from 2 to 20 months. There was no case of re-rupture, but tenolysis was performed in 1 cases. In all 6 cases, the average active range of motion of distal interphalangeal joint was 50.8 degree. The grip strength (ipsilateral/contralateral) was measured as 88.7% and the pulp pinch test was 79.2% as those of contralateral side. Flexion contracture was presented in 2 cases (15 degree on average) and there was no quadrigia effect found. Conclusion: Despite short length of tendon from the insertion site in FDS rupture in zone 1a and distal parts of zone 1b, sufficient functional recovery could be expected with the tendon to tendon repair using the modified loop suture technique.

Flexor Tenorrhaphy Using Absorbable Suture Materials

  • Kang, Hyung Joo;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.397-403
    • /
    • 2012
  • Background Nonabsorbable sutures are favorable for repairing flexor tendons. However, absorbable sutures have performed favorably in an animal model. Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanone absorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingers from 41 consecutive patients. The medical records of average 42 follow up weeks were analyzed retrospectively. The data analyzed using the chi-squared test, and Fisher's exact test was used for postoperative complications. The results were compared with those of other studies. Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and 13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in our study, there were 26 (47%) isolated flexor digitorum profundus (FDP) injuries and 29 (53%) combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted. Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers); nerve injuries occurred in 5 patients (10 fingers). Two patients had ruptures (3.6%), and one patient had two adhesions (3.6%). Using the original Strickland criteria, all the patients were assessed to be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitch granuloma were less likely occurred in our study. Compared to the Cullen's report that used nonabsorbable sutures, there was no significant difference in the rupture or adhesion rates. Conclusions Therefore, this study suggests that appropriate absorbable core sutures can be used safely for flexor tendon repairs.

The Effect of Alloderm on Prevention of Adhesions following Tenorrhaphy in the Rabbits (알로덤이 건 봉합술 후 발생되는 유착 방지에 미치는 효과)

  • Choi, Chang Yong;Song, Jin Woo;Kim, Jun Hyuk;Choi, Hwan Jun;Lee, Young Man
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.765-770
    • /
    • 2007
  • Purpose: Peritendinous adhesion is one of the most notorious complication after the flexor tendon injury. In this study, $Alloderm^{(R)}$(LifeCell Corp., Branchburg, N.J.), which is the decellularized human dermal analogue with its intact native basement membrane components, was used for the prevention of peritendinous adhesions following flexor tendon repair. Methods: Thirty New Zealand white male rabbits were divided equally into 3 groups. In all groups, the flexor digitorum profundus of the third finger of the right back foot was cut totally and repaired by modified Kessler suture technique. Following tendon repair, $Alloderm^{(R)}$ was wrapt around the repaired tendon in the first group and sodium hyaluronate gel was sprayed to the operation field in the second group. In the control group, no external material was applied. The right back foot were immobilized for 6 weeks to optimize the formation of adhesion ingrowth. After death, the third finger that repaired tendons and sheaths was removed en bloc. We checked range of motion. and studied histologically for all groups. Results: The experimental groups had better range of motion than the control group. We checked that the range of motion was 73.5 degrees in $Alloderm^{(R)}$ group, 55.9 degrees in the hyaluronic acid group, and 38.3 degrees in the control group. in the histological study, the experimental group had less adhesions compared with the control group. Conclusion: This study concludes that $Alloderm^{(R)}$ can decrease peritendinous adhesions following flexor tendon repairs in rabbits. We think the method could be used in clinical cases.

Pollicization of the Middle Finger

  • Bahk, Sujin;Eo, Su Rak;Cho, Sang Hun;Jones, Neil Ford
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.62-67
    • /
    • 2015
  • Purpose: Pollicization typically involves surgical migration of the index finger to the position of the thumb. This procedure facilitates the conversion of a useless hand into a well-functioning one in patients who are not amenable to the toe-to-hand transfer. However, middle finger pollicization has been rarely reported. Materials and Methods: We reconstructed a thumb by immediate pollicization of the remnants of the middle finger in two patients who sustained a tumor and a trauma, respectively. The former, after cancer ablation was performed, has not been reported literally, and the latter involved free devitalized pollicization of the middle finger using a microsurgical anastomosis. The distal third extensor communis tendon was sutured to the proximal extensor pollicis longus tendon and the distal flexor digitorum superficialis and profundus were sutured to the proximal flexor pollicis longus. The abductor pollicis brevis tendon was sutured to the distal end of the first palmar interosseous muscle. Coaptation of the third digital nerve and the superficial radial nerve branch was performed. Results: Patients showed uneventful postoperative courses without complication such as infection or finger necrosis. Based on the principles of pollicization, a wide range of pinch and grasp movements was successfully restored. They were pleased with the functional and cosmetic results. Conclusion: Although the index finger has been the digit of choice for pollicization, we could also use the middle finger on specific occasions. This procedure provides an excellent option for the reconstruction of a mutilated thumb and could be performed advantageously in a single step.