• 제목/요약/키워드: Flexor carpi ulnaris muscle

검색결과 25건 처리시간 0.027초

Anatomical Study on the Heart Meridian Muscle in Human

  • Park Kyoung-Sik
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.11-17
    • /
    • 2005
  • This study was carried out to identify the components of the human heart meridian muscle, the regional muscle group being divided into outer, middle, and inner layers. The inner parts of the body surface were opened widely to demonstrate muscles, nerves, blood vessels and to expose the inner structure of the heart meridian muscle in the order of layers. We obtained the following results; $\cdot$ The heart meridian muscle is composed of muscles, nerves and blood vessels. $\cdot$ In human anatomy, the difference between terms is present (that is, between nerves or blood vessels which control the meridian muscle and those which pass near by). $\cdot$ The inner composition of the heart meridian muscle in the human arm is as follows: 1) Muscle H-l: latissimus dorsi muscle tendon, teres major muscle, coracobrachialis muscle H-2: biceps brachialis muscle, triceps brachialis muscle, brachialis muscle H-3: pronator teres muscle and brachialis muscle H-4: palmar carpal ligament and flexor ulnaris tendon H-5: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficialis tendon, flexor digitorum profundus tendon H-6: palmar carpal ligament & flexor retinaculum, flexor carpi ulnaris tendon H-7: palmar carpal ligament & flexor retinaculum, tissue between flexor carpi ulnaris tendon and flexor digitorum superficial is tendon, flexor digitorum profundus tendon H-8: palmar aponeurosis, 4th lumbrical muscle, dorsal & palmar interrosseous muscle H-9: dorsal fascia, radiad of extensor digiti minimi tendon & extensor digitorum tendon 2) Blood vessel H-1: axillary artery, posterior circumflex humeral artery H-2: basilic vein, brachial artery H-3: basilic vein, inferior ulnar collateral artery, brachial artery H-4: ulnar artery H-5: ulnar artery H-6: ulnar artery H-7: ulnar artery H-8: palmar digital artery H-9: dorsal digital vein, the dorsal branch of palmar digital artery 3) Nerve H-1: medial antebrachial cutaneous nerve, median n., ulnar n., radial n., musculocutaneous n., axillary nerve H-2: median nerve, ulnar n., medial antebrachial cutaneous n., the branch of muscular cutaneous nerve H-3: median nerve, medial antebrachial cutaneous nerve H-4: medial antebrachial cutaneous nerve, ulnar nerve H-5: ulnar nerve H-6: ulnar nerve H-7: ulnar nerve H-8: superficial branch of ulnar nerve H-9: dorsal digital branch of ulnar nerve.

  • PDF

Effect of Functional Pressure Garments on EMG Response of the Agonist during the Resistance Exercise of the Wrist and Elbow Joint

  • Kim, Ki Hong;Kim, Byung Kwan;Jeong, Hwan Jong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제12권1호
    • /
    • pp.81-89
    • /
    • 2020
  • The purpose of this study is to investigation the effects of functional compression clothing on muscle function by comparing the iEMG response of muscle during exercise according to the wearing of taping applied functional clothing. Six men in their twenties in Chungcheongnam-do were selected for the study. Resistance exercise was performed by cross-distributing the conditions of wearing and not wearing functional clothing. Resistance exercises for iEMG measurements are biceps curl, wrist curl, reverse wrist curl, kickback and push-up. iEMG measurement muscles were the biceps brachii, triceps brachii, extensor carpi ulnaris, flexor carpi radialis. During biceps curl exercise, the iEMG of triceps brachii, biceps brachii wearing condition was lower than the non-wearing condition. During kickback exercise, the iEMG of triceps brachii, extensor carpi ulnaris wearing condition was lower than the non-wearing condition. During reverse wrist curl exercise, the iEMG of extensor carpi ulnaris wearing condition was lower than the non-wearing condition. During wrist curl exercise, the iEMG of flexsor biceps brachii, carpi radialis wearing condition was lower than the non-wearing condition. During push-up exercise, the iEMG of triceps flexsor biceps brachii, carpi radialis, brachii, biceps brachii non-wearing condition was lower than the wearing condition.

어깨, 팔꿈치, 손목의 자세에 따른 최대악력과 근육활동에 관한 연구 (Effects of Combinational Posture of Shoulder, Elbow and Wrist on Grip Strength and Muscle Activity)

  • 김태형;정승래;강성식;장성록
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.111-119
    • /
    • 2016
  • This study aimed to analyze postures that were frequently conducted in manufacturing industry. To find grip strength and muscle activities of each posture, Maximum Voluntary Contraction (MVC) and ElectroMyoGraphy (EMG) were measured. Based on the results of this study, the most appropriate posture could be suggested and used as a basic information for preventing musculoskeletal disorders. Most work-related musculoskeletal disorders have been occurred in the fields of manufacturing industry. According to previous studies, it was reported that the rate of musculoskeletal diseases of upper extremity was higher than that of other body parts. Accordingly, there were many studies about discomfort and grip strength of upper extremity. However, these studies dealt with single selection of wrist, elbow and shoulder. So, it was insufficient for comprehensive studies about upper extremity. And in order to improve the work posture, the physiological changes being generated by the combination of wrist, elbow and shoulder postures should be observed and analyzed. In order to conduct this study, thirty university students who had no records of MSDs involved were recruited. Independent variables were postures of wrist(pronation, neutral, supination), postures of elbow(flexion $45^{\circ}$, $90^{\circ}$) and postures of shoulder(flexion $0^{\circ}$, $90^{\circ}$). And dependent variables were MVC values and EMG values. Jamar dynamometer and TeleMyo 2400T G2 was used to measure MVC and EMG. MVC and EMG for 12 postures were measured for three second and for three times. Experiment was performed randomly. A 10 minutes rest period was provided after each t. To measure muscle load, the EMG signals of eight muscles (Biceps, Medial triceps, Lateral triceps, Brachioradialis, Extensor carpi ulnaris, Extensor carpi radialis, Flexor carpi ulnaris and Flexor carpi radialis) were evaluated. MVC values and EMG values were analyzed using Minitab ver. 14. The results showed that MVC value was the highest at shoulder $0^{\circ}$, elbow $45^{\circ}$ and wrist supination. In case of wrist postures, MVC of supination is the highest. In case of elbow and shoulder postures, MVC of flexion $45^{\circ}$ and $0^{\circ}$ was the highest. It was found that there were interaction between wrist and elbow posture under shoulder flexion and between shoulder and wrist under elbow flexion $45^{\circ}$. In case of the angle of shoulder $0^{\circ}$, elbow $45^{\circ}$ and wrist supination, the EMG values of four muscles(Medial Triceps, Extensor carpi ulnaris, Extensor carpi radialis, Flexor carpi ulnaris) were the highest. Based on this study, it is worth to note that the combination postures of upper extremity have a large impact on the MVC and EMG. The optimal condition upper extremity was shoulder flexion $0^{\circ}$, elbow flexion $45^{\circ}$ and wrist supination for preventing work-related musculoskeletal disease.

Electromyographic Analysis of Upper and Lower Limb Muscles during Gardening Tasks

  • Park, Sin-Ae;Lee, A-Young;Kim, Jai-Jeong;Lee, Kwan-Suk;So, Jae-Moo;Son, Ki-Cheol
    • 원예과학기술지
    • /
    • 제32권5호
    • /
    • pp.710-720
    • /
    • 2014
  • Movements of the upper and lower limb muscles during five common gardening tasks were analyzed by using electromyography (EMG). Twenty adults aged in their twenties (mean age, $24.8{\pm}2.4$ years) were recruited. On two separate occasions, subjects visited a garden plot to perform digging, raking, troweling, weeding, and hoeing; all tasks were performed three times with 20 s intervals for each trial. To measure muscle activation during the five gardening tasks, surface EMG was used. Bipolar surface EMG electrodes were attached to eight upper limb muscles (bilateral anterior deltoid, biceps brachialis, brachioradialis, and flexor carpi ulnaris) or eight lower limb muscles (bilateral vastus lateralis, vastus medialis, biceps femoris, and gastrocnemius) on both sides of the body, for a total of 16 muscles. During the five tasks, photographs were taken of movement phases using a digital video camera. The right flexor carpi ulnaris and brachioradialis showed higher activation than the other upper and lower limb muscles measured during the tasks. All 16 upper and lower limb muscles were actively used only during digging. According to movement analysis of each activity, digging was classified into four movement phases, whereas raking, troweling, weeding, and hoeing each were divided into three movement phases. In each activity, there were high-impact phases in terms of muscle activation; the flexor carpi ulnaris and brachioradialis were identified as major muscles in each impact phase. This analysis may be used to generate biomechanical profiles of gardening tasks for practitioners when designing efficient gardening interventions for physical health or rehabilitation.

Activities of Upper Limb Muscles Related to the Direction of Elastic Tape Application in Healthy Adults: A Randomized Trial of Parallel-Aligned Versus Cross-Aligned Tape Application

  • Oh, Duck-Won;Chon, Seung-Chul
    • 한국전문물리치료학회지
    • /
    • 제20권4호
    • /
    • pp.9-15
    • /
    • 2013
  • The purpose of this study was to evaluate the differences in electromyographic (EMG) activities of upper limb muscles between cross- and parallel-aligned taping and to compare the effects of these 2 taping methods in healthy adults. Thirty subjects, who volunteered for this study, were tested under 3 taping conditions in random order: (1) no taping, (2) cross-aligned taping, and (3) parallel-aligned taping. EMG activities of the biceps brachii, triceps brachii, flexor carpi ulnaris, and extensor carpi radialis muscles were measured. All muscles showed significant differences in EMG activity among the 3 conditions (p<.05). In the post hoc test, biceps brachii and triceps brachii muscles showed significant differences in EMG activity between the no taping and the cross-aligned taping conditions and between the no taping and the parallel-aligned taping conditions. Additionally, the EMG activities of the flexor carpi radialis and extensor carpi radialis muscles appeared to be significantly different between the no taping and parallel-aligned taping conditions. These findings demonstrate that taping may be helpful for decreasing muscle activity, regardless of the direction of tape application. This study provides useful information to future researchers regarding the effects of taping on muscle activity.

Comparison of Muscle Activity Between Handwriting and Touchscreen Use in Younger Adults and the Elderly

  • Min, Se-Ra;Jung, Young-Jin;Yoon, Tae-Hyung;Jung, Nam-Hae;Kim, Tae-Hoon
    • International Journal of Contents
    • /
    • 제16권1호
    • /
    • pp.57-64
    • /
    • 2020
  • We sought to compare upper extremity muscle activity between handwriting on paper and touchscreen with dominant and non-dominant hands in younger adults (age 23.90±1.12) and the elderly (age 75.55±5.76). Muscle activity (percent of maximum voluntary contraction) in the biceps brachii muscle, triceps brachii muscle, flexor carpi ulnaris muscle, and extensor carpi ulnaris muscle was measured using an electromyography device. As a result, our data indicate that muscle activity is lower in younger adults than the elderly. Besides, muscle activity is lower in the dominant versus non-dominant hand, and lower when writing using a touchscreen than on paper. These results can be used to support recommending touchscreens in the elderly. Also, they can be used as baseline data for comparing the performance of non-paretic side and paretic side in patients relative to the central nervous system.

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • 대한인간공학회지
    • /
    • 제35권6호
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.

수태양소장경근(手太陽小腸經筋)에 대한 근육학적(筋肉學的) 고찰(考察) (The study of muscular system about small intestine channel of hand taiyang muscle)

  • 김지남;김영일;홍권의;임윤경;이현
    • 혜화의학회지
    • /
    • 제14권1호
    • /
    • pp.67-81
    • /
    • 2005
  • We have conclusions after the study of muscular system about small intestine channel of hand taiyang muscle. Judging from many studies of interrelation between Meridian muscle and muscle, it is considered that Meridian muscle theory has some similarities with modern anatomical muscular system. It is considered that Small intestine channel of hand taiyang muscle contains Flexor digitorum profundus muscle, Extensor digiti minimi muscle, Abductor digiti minimi muscle, Extensor carpi ulnaris muscle, Flexor carpi ulnaris muscle, Triceps brachii muscle, Infraspinatus muscle, Levator scapulae muscle, Sternocleidomastoid muscle, Masseter muscle, Temporalis muscle. The symptoms of small intestine channel of hand taiyang muscle is similar to referred pain of modern Myofascial Pain Syndrome, and the medical treatment of "I Tong Wi Su(以痛爲輸)" is also similar to that of Myofascial Pain Syndrome. Small intestine channel of hand taiyang muscle is one of the three yang channels of hand muscle, and it has unity in extension of upper limb and trunk in the movement. And it is thought that weakness of small intestine channel of hand taiyang muscle is related with muscular system causing Round Shoulder and Head Forward Position.

  • PDF

Control of IPMC-based Artificial Muscle for Myoelectric Hand Prosthesis

  • Lee Myoung-Joon;Jung Sung-Hee;Moon Inhyuk;Lee Sukmin;Mun Mu-Seong
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.257-264
    • /
    • 2005
  • This paper proposes an ionic polymer metal composite (IPMC) based artificial muscle to be applicable to the Myoelectric hand prosthesis. The IPMC consists of a thin polymer membrane with metal electrodes plated chemically on both faces, and it is widely applying to the artificial muscle because it is driven by relatively low input voltage. The control commands for the IPMC-based artificial muscle is given by electromyographic (EMG) signals obtained from human forearm. By an intended contraction of the human flexor carpi ulnaris and extensor carpi ulnaris muscles, we investigated the actuation behavior of the IPMC-based artificial muscle. To obtain higher actuation force of the IPMC, the single layered as thick as $800[{\mu}m]$ or multi-layered IPMC of which each layer can be as thick as $178[{\mu}m]$ are prepared. As a result, the bending force was up to the maximum 12[gf] from 1[gf] by actuating the single layered IPMC with $178[{\mu}m]$, but the bending displacement was reduced to 6[mm] from 30[mm]. The experimental results using an implemented IPMC control system show a possibility and a usability of the bio-mimetic artificial muscle.

노트북 거치대가 건강한 젊은 성인 손목관절근육의 생체역학적 특징에 미치는 영향 (Effects of a Notebook Computer Supporter on Biomechanical Characteristics in Wrist Joint Muscles of Healthy Young Adults)

  • 마성룡;송창순
    • PNF and Movement
    • /
    • 제19권3호
    • /
    • pp.391-399
    • /
    • 2021
  • Purpose: As laptop use increases throughout the COVID-19 pandemic and its use outside of traditional workstations proliferates, it is imperative to expand the limited research available regarding ergonomic exposure. This study aimed to identify the effects of a laptop supporter on biomechanical characteristics in the wrist joint muscles of healthy young adults. Methods: This was a cross-sectional observational study design with thirty-four healthy young adults as participants. They conducted a typing exercise performed under two different conditions, which were with and without a notebook computer supporter. This study measured the biomechanical characteristics of the muscles of the wrist joints including the flexor carpi ulnaris (FCU), the flexor carpi radialis (FCR), the extensor carpi radialis longus (ECRL), and the extensor carpi ulnaris (ECU). Measurements were taken three times: before typing, immediately after typing for 30 minutes with a supporter, and immediately after typing for 30 minutes without a supporter. The statistical method to compare the three different measurement conditions was the repeated measures ANOVA. Results: The participants showed significantly different levels of dynamic stiffness in both the FCU before typing and immediately after 30 minutes of typing with a supporter, and showed significantly different levels of dynamic stiffness in the FCR before typing and immediately after 30 minutes of typing with a supporter. The dynamic stiffness level immediately after 30 minutes of typing without a supporter was significantly different than that immediately after 30 minutes of typing with a supporter. However, the muscle tone was not significantly different among the three different conditions. Conclusion: The results of this study revealed that a laptop supporter used to correct the eye level of the electronic screen increases the dynamic stiffness of the wrist joint flexors, so it is necessary to consider the neutral position of the wrist joint during typing.