• Title/Summary/Keyword: Flexible tube

Search Result 130, Processing Time 0.024 seconds

Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract

  • Choe, Jae Young;Choe, Byung-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.2
    • /
    • pp.132-141
    • /
    • 2019
  • Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnetattached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).

Reliability Analysis of Exhaust Bellows Based on ALT (가속 수명 시험을 이용한 자동차용 배기 벨로우즈의 수명 해석)

  • Kim, Hyung-Min;Wee, Shin-Hwan;Kim, Tae-Soo;Kim, Sung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1667-1672
    • /
    • 2007
  • In order to assess the reliability of the exhaust bellows for automobiles, accelerated life test model and procedure are developed. By using this method, failure mechanism and life distribution are analyzed. The main results are as follows; i) the main failure mechanism is crack or breakage of inner flexible tube by shaken displacement at shear direction. ii) temperature is a second factor to affect a failure. iii) the life distribution of exhaust bellows is fitted well to Weibull life distribution and the shape parameter is 13.3 on condition of shaken displacement and $600^{\circ}C$

  • PDF

IDENTIFICATION OF AIRWAY CHARACTERISTICS USING THE INPUT IMPEDANCE

  • Tung, V.X.;Jumaily, Al;Cheng, S.H.;Ro, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1037-1044
    • /
    • 2007
  • In an attempt to determine the correlations between the input acoustic impedance and the variations of the physical characteristics of the terminal elements, a five-lobe branched tube-network is mathematically developed and experimentally simulated using a lung simulator. The model takes into account some realistic conditions such as varying cross-sectional areas, flexible wall properties and branching. The effects of airway constrictions expressed by lobe stiffness variations on the impedance are determined for a range of frequencies up to 256 Hz. It is concluded that the developed model is capable of non-invasively predicting various physiological changes in the airway passages.

  • PDF

Clinical Applications of the Tubular Retractor on Spinal Disorders

  • Kim, Young-Baeg;Hyun, Seung-Jae
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.245-250
    • /
    • 2007
  • Tubular retractor system as a minimally invasive surgery (MIS) technique has many advantages over other conventional MIS techniques. It offers direct visualization of the operative field, anatomical familiarity to spine surgeons, and minimizing tissue trauma. With technical advancement, many spinal pathologies are being treated using this system. Namely, herniated discs, lumbar and cervical stenosis, synovial cysts, lumbar instability, trauma, and even some intraspinal tumors have all been treated through tubular retractor system. Flexible arm and easy change of the tube direction are particularly useful in contralateral spinal decompression from an ipsilateral approach. Careful attention to surgical technique through narrow space will ensure that complications are minimized and will provide improved outcomes. However, understanding detailed anatomies and keeping precise surgical orientation are essential for this technique. Authors present the technical feasibility and initial results of use a tubular retractor system as a minimally invasive technique for variaties of spinal disorders with a review of literature.

Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor (딥스틱게이지형 소형 엔진열화감지센서 개발)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

Fabrication of 100m Class Bi-2223 High Temperature Superconductir (100m급 Bi-2223 고온초전도 선재 제조)

  • 하홍수;오상수;하동우;장현만;이남진;이준석;정대영;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.10-13
    • /
    • 1999
  • For large scale applications of high temperature superconductor(HTS) such as transmission cables, motors and generators, long length of flexible HTS conductors is required. Currently, HTS tape that is capable of being fabricated in long length by industrial processes is the Bi-2223 HTS tape. In this study, we fabricated 19 filamentary Bi-2223($Bi_{1.8}$$Pb_{0.4}$$Sr_{2}$$Ca_{2}$$Cu_{3}$$O_{10+X}$) HTS tape with 100m length by PIT(Powder In Tube) process. Critical current(Ic) of this long length tape was measured 18.5 A at 77 K, self field and short sample Ic is 32.5 A at the same condition. Critical current of 100m length tape was decreased by about 1/3 compared to that of short tape. This was mainly resulted from the increase of non homogeneity in oxide layer.

  • PDF

Fabrication and performance of 100 m Class Bi-2223 High Temperature Superconducting Tape (100 m급 Bi-2223 고온초전도 선재 제조 및 특성)

  • 하홍수;오상수;하동우;장현만;이남진;류강식;이준석
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.15-19
    • /
    • 1999
  • For large scale applications of high temperature superconductor (HTS) such as transmission cables, motors and generators, long length of flexible HTS conductor is required. Currently, Bi-2223 HTS tape is capable of being fabricated in longer than 100 m length by industrial processes. In this study, we fabricated 100 m 19 filamentary Bi-2223 ($Bi_{1.8}Pb_{0.4}Sr_2Ca_2O_{10+x}$) HTS tape by PIT (Power in Tube) process. Critical current(IC) of this long length tape was measured 18.5 A at 77K, self field. Critical current of 100 m length tape was mainly resulted from the increase of inhomogeneity in oxide from the increase of inhomogeneity in oxide layer. Engineering critical current (Je=Ic/total tape cross-section area) that is important factor for practical applications and fabrication cost was measured 2.2 kA/cm2.

  • PDF

2D-Axisymmetric Fluid Simulation of TEM Waveguide Linear Microwave Plasma Source

  • Han, Mun-Gi;Seo, Gwon-Sang;Yun, Yong-Su;Kim, Dong-Hyeon;Lee, Hae-Jun;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.222.1-222.1
    • /
    • 2014
  • Flexible device 및 OLED 디스플레이 제조를 위한 산화물 반도체 보호막 증착 및 encapsulation 공정을 위해 균일한 대면적 플라즈마를 만들기 위한 다양한 연구가 진행되고 있다. 초고주파 플라즈마는 고밀도, 고효율의 플라즈마를 저진공에서 쉽게 생성시킬 수 있고 다양한 전력결합방법을 통해 대면적 확장성이 우수한 장점이 있다. 본 연구에서는 TEM 웨이브가이드로 파워가 전달되는 선형 초고주파 플라즈마 소스에 대한 2차원축대칭 유체 시뮬레이션을 수행하였다. Ar 가스 압력과 초고주파 입력전력이 증가함에 따라 전자밀도가 증가하였고 도파관 방향으로 플라즈마의 길이가 증가함이 관측되었다. Quartz Tube 표면 가까이에서 전자밀도가 가장 높게 나타났다. 전자의 에너지 손실 채널중 가장 많은 부분을 차지하는 것은 여기종 생성에 따른 에너지 손실이었으며 탄성 충돌에 의한 에너지 손실이 두 번째로 큰 부분을 차지하였다.

  • PDF

Attenuation Characteristics of Fluid-Borne Pressure Ripple in Automotive Power Steering Hydraulic Hoses (자동차 동력조향용 유압호스의 압력맥동 감쇠특성)

  • 김도태
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.3
    • /
    • pp.22-28
    • /
    • 1998
  • This paper presents experimental investigations on the attenuation characteristics of pressure ripple in automotive power steering hydraulic hoses. Also, a mathematical model of hydraulic hoses is proposed to support design of the power steering hydraulic circuit and analyze the attenuation characteristics of pressure ripples. The experimental results show that the pulsation attenuation characteristics of hydraulic hoses is remarkably affected by the flexible metal tube inserted coaxially inside a hydraulic hose with a finite length as well as viscoelastic properties of hose wall. It is also shown that the predicted results by the model proposed here agree well with the measured results over a wied range of frequency.

  • PDF

The study on the measurement for the pressure drop and friction factor of corrugated metal pipes (주름관에서의 압력강하와 마찰손실 계측에 관한 연구)

  • Yun, Young-Sun;Kang, Jun-One;Yoo, Jai-Suk;Kim, Hyung-Jung
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF