• 제목/요약/키워드: Flexible tube

검색결과 130건 처리시간 0.033초

THE INFLUENCE OF DRIVING FUNCTION ON FLOW DRIVEN BY PUMPING WITHOUT VALVES

  • Jung, Eun-Ok
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제15권2호
    • /
    • pp.97-122
    • /
    • 2011
  • Fluid dynamics driven by pumping without valves (valveless pumping) shows interesting physics. Especially, the driving function to generate valveless pump mechanism is one of important factors. We consider a closed system of valveless pump which consists of flexible tube part and stiffer part. Fluid and structure (elastic tube) interaction motions are generated by the periodic compress-and-release actions on an asymmetric location of the elastic loop of tubing. In this work, we demonstrate how important the driving forcing function affects a net flow in the valveless circulatory system and investigate which parameter set of the system gives a more efficient net flow around the loop.

유연 우주구조물의 열적 유기 진동에 관한 연구 (A Study on Thermally-Induced Vibration of Flexible Space Structures)

  • 공창덕;오경원
    • 한국항공우주학회지
    • /
    • 제31권9호
    • /
    • pp.46-54
    • /
    • 2003
  • 본 연구의 목적은 유연 우주구조물이 급격한 열적 환경에 의해 발생되는 진동을 수치적인 계산과 실험을 통해 규명하는데 있다. 단순화한 유연 구조물에 대해 수치적인 접근과 지상 실험실에서 실험한 데이터를 비교 분석하였다. 분석결과 유연 구조물이 급속한 복사 열에 의해 열적 모멘트에 의한 열적 변위가 발생하고 온도의 미소한 주기적 변화로 열 유기 진동이 발생함이 밝혀졌다. 수치해석치와 실험치를 비교한 결과 끝단질량이 없는 경우, 1차 모드 진동수는 0.78Hz로 두 값이 일치하였으나, 끝단 질량이 있는 경우, 끝단 질량이 각각 8g, 16g, 50g, 100g으로 증가할 때 1차 모드의 진동수에 있어 예측치는 1.75Hz, 1.3Hz, 0.87Hz, 0.73Hz이고 실험치는 2.34Hz, 1.5Hz, 0.78Hz, 0.78Hz로 감소하는 경향을 보이며 비록 예측치가 단순화 공식을 이용함에도 불구하고 실험치에 근접하였다.

원형강관으로 구속된 콘크리트의 역학적 거동 특성에 관한 연구 (A Study on Properties of Mechanical Behaviors of Concrete Confined by Circular Steel Tube)

  • 박정민;김화중
    • 콘크리트학회지
    • /
    • 제7권3호
    • /
    • pp.199-210
    • /
    • 1995
  • 충전형 강관콘크리트 구조는 강관과 콘크리트 두 재료의 이질적인 재료특성을 상호 보완적으로 발휘하여 구조적 성능향상을 꾀한 것으로서 제구조 특성상 우수한 구조형식이라 할 수 있다. 강관으로 구속된 콘크리트가 중심축력을 받게 되면 내부의 콘크리트는 압괴에 의한 체적 팽창을 외부의 강관에 의해 구속 받게 되므로 3축 압축응력 상태로 되어 압축강도가 증대된다. 또한 콘크리트의 압괴에 의한 탈락 현상이 방지되므로서 단면의 결손이 없어져 내력 저하가 작아진다는 잇점을 가진다. 따라서 본 연구에서는 원형강관으로 구속된 내부 콘크리트의 구조적 거동 특성을 규명하기 위한 것으로서 폭두께비와 충전 콘크리트의 강도를 주요 변수로 하여 일련의 실험을 통하여 강관으로 구속(3축 응력)된 콘크리트의 구조적 거동 특성을 고찰하였다. 일련의 실험을 통하여 얻어진 결론을 요약하면 다음과 같다. (1)강관에 의한 콘크리트의 구속효과는 강관의 폭두께비와 충전 콘크리트의 강도가 낮을수록 현저하며, 원형강관으로 구속된 내부 콘크리트는 최대내력시의 변형능력에 있어서 횡방향 구속이 없는 콘크리트보다 4~7배 정도까지 증대시켜 연성효과를 높일 수 있을 것으로 기대된다. (2)콘크리트의 구속계수를 이용하여 강관으로 구속된 내부 콘크리트의 강도와 콘트리트 충전강관 기둥의 최대내력을 산정할 수 있는 식을 제시하였다.

극세관 헬리컬 코일형 열교환기에 관한 연구 (A Study on the Helically Coiled Heat Exchanger of Small Diameter Tubes)

  • 김주원;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1492-1499
    • /
    • 2001
  • In order to develop the compact and flexible heat exchangers, we made the helically coiled heat exchangers. They can be manufactured with small diameter copper tubes without the need for fins; inner diameter=1.0 mm, straight tube length=1.5 m. The experiments were carried out with the following conditions; evaporation pressure=0.6 MPa, air velocity=0.7 ∼ 1.7 m/s, and working fluid=R-22. Pressure drop and heat transfer coefficient of heat exchangers were experimented according to the air velocity. The results of heat transfer coefficient show a 35% beneficial increase fur these heat exchangers over the other covered fin-tube heat exchangers. A cooling capacity of about 3 kW was obtained with an air velocity of 1.5 m/s. The distribution header has also been designed fur efficient distribution of refrigerant flow.

보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성 (Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel)

  • 유영선;강금춘;김영중;백이;강연구;이형모
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

선박의 직진과 선회 시의 프로펠러 하중이 프로펠러 축 베어링에 미치는 영향 (Effects of Propeller Forces on the Propeller Shaft Bearing during Going Straight and Turning of Ship)

  • 신상훈
    • 대한조선학회논문집
    • /
    • 제52권1호
    • /
    • pp.61-69
    • /
    • 2015
  • In the beginning of the 1990's, numerous shaft bearing damages, especially in aft stern tube bearing, were reported. The main reasons of bearing damages were estimated that hull deflections have been increased by more flexible hulls and propeller dynamic loads have not been considered in shaft alignment. After that time, studies to take into account hull deflections in shaft alignment have been actively carried out, but for the latter leave much to be desired. In this study, the effects of the propeller forces on the propeller shaft bearing have been investigated by estimating thrust eccentricity as reasonable as possible although some assumptions to simulate turning of ship were introduced. Three dimensional nominal wake to estimate thrust eccentricity have been calculated by using CFD analysis and model test in the towing tank. This study presents the procedure to estimate the propeller eccentric forces and their influence on the stern tube bearing for a container carrier. As a result, it has been found that the lateral propeller forces in turning condition should be considered in shaft alignment to prevent shaft bearing damages.

2상 횡유동을 받는 튜브군의 유체탄성 불안정성 (Fluid-Elastic Instability of Tube Bundles in Two-Phase Cross-Flow)

  • 김범식;장효환
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.1948-1966
    • /
    • 1991
  • 본 연구에서는 2상 횡유동을 받는 튜브군의 진동 메카니즘을 규명하기 위한 실험계획의 일환으로 실시된 실험으로부터 튜브군의 유체탄성 불안정성 상수에 관해 고찰하였다. 실험은 먼저 p/d=1.47 및 1.32 튜브군에 대해 수행되었는데, 이들 튜브 군의 결과는 참고문헌에 발표하였다. 본 논문은 후속 실험으로 수행된 p/d=1.22인 튜브군을 사용하여 유체탄성 불안정성 상수를 고찰한 참고문헌의 후속논문이다. 실 험은 액체상태로 부터 99% 보이드율(void fraction)까지 변화된 2상 유동에서 튜브가 유체탄성 불안정성 상태에 도달할 때까지 점진적으로 증가하였다.실험결과는 p/d= 1.32 alc 1.47 튜브군의 유체탄성 불안정성 결과들과 종합. 비교되었다.

고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측 (A Evaluation on the Field Application of High Strength Concrete for CFT Column)

  • 박제영;정경수;김우재;이종인;김용민
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.707-714
    • /
    • 2014
  • 콘크리트 충전강관(CFT)은 강관의 내부에 콘크리트로 채워진 기둥이다. CFT는 강재와 콘크리트로 구성되며, 강재는 콘크리트를 내부에서 구속시켰고, 내부 콘크리트는 기둥의 압축하중을 감당한다. 본 실험에서 73~100MPa급 고강도 콘크리트에 관해 유동성실험, 압축강도실험, 압송압력실험을 실시하였으며, CFT용 고강도 콘크리트의 물리적 성질을 알아보기 위해 슬럼프, 슬럼프 플로우, 공기량, U-box시험, O-Lot시험, L-flow시험이 진행되었다. 이러한 연구의 결과를 바탕으로 Mock-up테스트에서 콘크리트 충전성 시험, 수화열 측정 시험, 응력계측 시험을 수행하였다. 현장적용은 상암동 및 서강대 현장의 두 곳에 각각 ${\Box}-566{\times}566{\times}10$, ${\Box}-400{\times}400{\times}25$의 대상기둥을 선정하여 현장계측을 진행하였다. CFT기둥의 장기거동 예측에 관하여 설계하중에 대해 콘크리트의 탄성변형과 건조수축, 크리프 수축을 고려한 ACI 209 재료모델을 사용한 결과는 계측결과와 거의 일치하였다.

Supramolecular Assembly toward Organic Nanostructures

  • Lee, Myong-Soo
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.173-173
    • /
    • 2006
  • We have explored a strategy to control the supramolecular nano-structures self-assembled from rigid segments through attachment of flexible chains through microphase separation and anisotropic arrangement. Supramolecular structures formed by self-assembly of rigid building blocks can be precisely controlled from 1-D layered, 3-D bicontinuous cubic to 2-D cylindrical structures by systematic variation of the type and relative length of the respective blocks. Furthermore, depending on the individual molecular architectures, rigid building blocks self-assemble into a wide range of supramolecular structures such as honeycomb, disk, cylinder, helix, tube, barrel stave, and nano-cage.

  • PDF

매설조건에 따른 연성관의 변형특성 (Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions)

  • 이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제15권10호
    • /
    • pp.53-62
    • /
    • 2014
  • 국내의 경우 하수관으로 많이 사용되어 온 관종은 콘크리트 흄관으로 대표되는 강성관이 주를 이루고 있으나, 시간 경과에 따른 관 부식 및 수밀성 부족 등의 이유로 사용이 급격히 감소하고 있다. 반면에 연성관은 부식에 강할 뿐만 아니라 자재의 무게가 경량이어서 시공성이 우수한 장점이 있어 사용이 증가하고 있는 실정이다. 그러나 연성관에 대한 시장의 신뢰성 부족과 미흡한 다짐관리로 인한 국부적인 파손사례가 발생하고 있어 이에 대한 원인분석 및 관리방안이 필요한 실정이다. 이에 본 연구에서는 시공순서, 관의 강성, 관 하부 콘크리트 기초의 강도, 관 하부 모래기초의 다짐도, 관 주변 모래의 다짐도 및 관 상단 되메움재의 다짐도 등을 변화시켜 가며 각각의 조건에 따른 관의 변형특성을 수치해석을 통하여 평가하였다. 평가결과 각 인자에 대한 영향을 확인할 수 있었으며 특히 연성관의 경우 관 주변 모래의 품질관리가 중요한 것으로 나타났다.