• 제목/요약/키워드: Flexible electrodes

검색결과 223건 처리시간 0.03초

나노튜브 전극을 기반으로 한 플렉서블 양자점 감응 태양전지 (Flexible Cu-In-Se Quantum Dot-Sensitized Solar Cells Based on Nanotube Electrodes)

  • 김재엽
    • 한국분말재료학회지
    • /
    • 제26권1호
    • /
    • pp.45-48
    • /
    • 2019
  • Quantum dots (QDs) are an attractive material for application in solar energy conversion devices because of their unique properties including facile band-gap tuning, a high-absorption coefficient, low-cost processing, and the potential multiple exciton generation effect. Recently, highly efficient quantum dot-sensitized solar cells (QDSCs) have been developed based on CdSe, PbS, CdS, and Cu-In-Se QDs. However, for the commercialization and wide application of these QDSCs, replacing the conventional rigid glass substrates with flexible substrates is required. Here, we demonstrate flexible CISe QDSCs based on vertically aligned $TiO_2$ nanotube (NT) electrodes. The highly uniform $TiO_2$ NT electrodes are prepared by two-step anodic oxidation. Using these flexible photoanodes and semi-transparent Pt counter electrodes, we fabricate the QDSCs and examine their photovoltaic properties. In particular, photovoltaic performances are optimized by controlling the nanostructure of $TiO_2$ NT electrodes.

Highly Flexible and Transparent ISO/Ag/ISO Multilayer Grown by Roll-to-roll Sputtering System

  • Cho, Da-Young;Shin, Yong-Hee;Na, Seok-In;Kim, Han-Ki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.278.2-278.2
    • /
    • 2014
  • We have investigated the highly flexible and transparent Si-doped $In_2O_3$(ISO)/Ag/ISO multilayer grown on polyethylene terephthalate (PET) substrates using a roll-to-roll sputtering system. The electrical and optical properties of ISO/Ag/ISO multilayer electrodes depended on the insertion of a nano-size Ag layer. Due to the high conductivity of a nano-size Ag layer, the optimized ISO/Ag/ISO multilayer electrodes showed the lowest resistivity of $3.679{\times}10^{-5}Ohm-cm$, even though the ISO/Ag/ISO multilayer electrodes was sputtered at room temperature. Furthermore, the ISO/Ag/ISO multilayer electrodes exhibited a high transmittance of 86.33%, because of the anti-reflection effect, comparable to Sn-doped $In_2O_3$ (ITO) electrodes. In addition, the ISO/Ag/ISO multilayer electrodes had a very smooth surface morphology without surface defects and showed good flexibility. The flexible OSCs fabricated on ISO(30nm)/Ag(8nm)/ISO(30nm) multilayer electrode showed a power conversion efficiency of 3.272%. This result indicates that the ISO/Ag/ISO multilayer is a promising transparent conducting electrode for flexible OSCs.

  • PDF

Multilayer transparent electrodes for flexible and inverted-geometry OLEDs

  • Yoo, Seung-Hyup;Yun, Chang-Hun;Park, Jae-Woo;Cho, Hyun-Su
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1019-1021
    • /
    • 2008
  • Multilayer transparent electrodes (MTE) based on an ultrathin metal layer assisted by additional dielectric or semiconducting layers are investigated as electrodes in OLEDs including an inverted geometry. A special attention is paid to their tuning capability in injection behavior and to their potential for ultra-flexible electrodes.

  • PDF

유연성/신축성 전극의 제조 및 특성 (Preparation and Property of Flexible/Stretchable Electrodes)

  • 이기쁨;나창운
    • Elastomers and Composites
    • /
    • 제47권4호
    • /
    • pp.272-281
    • /
    • 2012
  • 최근 주목을 받고 있는 유연성/신축성 전극소재는 유연디스플레이, 센서, 유전탄성고분자 액추에이터 및 제너레이터, 스마트 수술도구 등과 같은 다양한 분야에서 활용이 가능하다. 유연성/신축성 전극소재는 다양한 형태의 기계적인 변형을 받게 되는데 이때 기계적인 변형에 맞춰 함께 변형될 뿐만 아니라 신축되어야 한다. 따라서 기계적 변형에서도 전극으로써 기능을 유지해야 하기 때문에 대단히 어려운 연구분야라 할 수 있다. 본 총설에서는 최근까지 연구된 유연성/신축성 전극소재의 제조와 특성을 소개하고자 한다.

유연 기판과 전극 사이의 접합력이 전극의 내구성에 미치는 영향 (Effect of Adhesion Strength Between Flexible Substrates and Electrodes on the Durability of Electrodes)

  • 임도연;김병준;김건휘;안태창
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.86-92
    • /
    • 2024
  • Flexible electronic devices are exposed to repeated mechanical deformation; therefore, electrode performance is an important element. Recently, a new technology has been developed to improve the adhesion strength between polymer substrates and metal thin films through the cross-linking reaction of bovine serum albumin (BSA) bioconjugation proteins; however, additional performance evaluation as an electrode is necessary. Therefore, in this study, we investigated the effect of adhesive strength between a flexible substrate and a metal thin film on the performance of a flexible electrode. Cracks and changes in the electrical resistance of the electrode surface were observed through outer bending fatigue tests and tensile tests. As a result of a bending fatigue test of 50,000 cycles and a tensile test at 10% strain, the change in the electrical resistance of the flexible electrode with a high adhesion strength was less than 40%, and only a few microcracks were formed on the surface; thus, the electrical performance did not significantly deteriorate. Through this study, the relationship between the adhesion strength and electrical performance was identified. This study will provide useful information for analyzing the performance of flexible electrodes in the commercialization of flexible electronic devices in the future.

Carbon nanotube based transparent electrodes for flexible displays using liquid crystal devices

  • Shin, Jun-Ho;Lee, H.C.;Lee, J.H.;Park, S.M.;Alegaonkar, P.S.;Yoo, J.B.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.897-899
    • /
    • 2007
  • Transparent electrodes for a flexible display based on the liquid crystal (LC) were formed by carbon nanotubes (CNTs) on polyethylene terephthalate (PET) substrates. The thin multi wall carbon nanotubes (t-MWNTs) networks for electrodes were obtained by filtration- transfer method from welldispersed CNTs solution.

  • PDF

Printed black internal conducting electrodes for flexible bistable cholesteric displays

  • Atkuri, H.M.;Lee, D.W.;Choi, B.O.;Kim, C.H.;West, J.L.
    • Journal of Information Display
    • /
    • 제12권2호
    • /
    • pp.97-99
    • /
    • 2011
  • We report flexible, bistable cholesteric displays utilizing polyester (PET) substrates with printed internal black electrodes. The black electrodes consist of carbon ink dispersed in butyl carbitol using a patented roll-to-roll gravure-offset printing. A transparent conducting polymer printed on PET serves as the counter electrode. The electro-optic material is a chiral nematic mixture dispersed in a low-concentration polymer binder. The device can be switched between scattering (black) and reflective (vibrant green) states upon application of an electric pulse. The internal black electrode enhances the contrast of the display and simplifies the roll-to-roll manufacture of flexible displays.

구리 나노 큐브를 전기 도금한 레이저 유도 그래핀 전극 기반의 글루코스 측정용 유연 센서 개발 (Development of Flexible Glucose Measurement Sensor Based on Copper Nanocubes Electroplated Laser Induced Graphene Electrode)

  • 김건종;김태헌;박정호
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.413-418
    • /
    • 2018
  • In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. $CO_2$ laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were $15.6{\Omega}/{\Box}$ and $19.6{\Omega}/{\Box}$, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity ($1643.31{\mu}A/mM{\cdot}cm^2$), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to $30^{\circ}$, $90^{\circ}$, and $180^{\circ}$ and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat.

유연전극을 이용한 대기압 부유전극 유전체 장벽 방전 플라즈마 (Atmospheric Pressure Floating Electrode-Dielectric Barrier Discharges (FE-DBDs) Having Flexible Electrodes)

  • 김준현;박창진;김창구
    • Korean Chemical Engineering Research
    • /
    • 제57권3호
    • /
    • pp.432-437
    • /
    • 2019
  • 유연전극 기반의 대기압 부유전극 유전체 장벽 방전 (floating electrode-dielectric barrier discharge, FE-DBD) 시스템을 개발하여 플라즈마 특성을 분석하였다. 유연한 파워전극(powered electrode)을 구성하는 유연유전체로 polytetrafluoroethylene (PTFE), polydiemethylsiloxane (PDMS), polyethylene terephthalate (PET)를 사용하여 플라즈마를 발생하였을 때 플라즈마의 광학적 세기와 전자온도는 파워전극에 인가하는 전압이 증가할수록 증가하였고, 전압이 일정할 때는 PTFE < PDMS < PET 순으로 증가하였다. 이는 유전체의 종류와 전압에 따른 축전용량의 변화로 설명할 수 있었고, 유연전극 기반의 대기압 FE-DBD 플라즈마의 특성은 유연한 파워전극을 구성하는 유전체와 파워전극에 인가되는 전압을 변화함으로써 조절될 수 있음을 의미한다. 유연전극 대기압 FE-DBD 시스템은 피부 곡면을 따라 플라즈마가 발생될 수 있으므로 플라즈마 메디신(plasma medicine)에 유용할 것으로 기대한다.

Characteristics of Graphene/Metal Grid Hybrid Transparent Conductive Films

  • Kim, Sung Man;Kang, Seong Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.429-429
    • /
    • 2013
  • We present a systematic study of the electrical, optical and electromechanical properties of flexible graphene/metal grid hybrid transparent conductive electrodes using 4-point prove method, ultraviolet/visible spectrometer and inner/outer bending test system. The hybrid electrodes were synthesized by depositing a silver grid on a graphene surface. The sheet resistance of hybrid electrodes was as low as 30 Ω/square, while the transmittance was 90%. The electromechanical properties as a function of the change of bending radius were evaluated by measuring the change in resistance. The result will be presented in detail. We believe that these results will provide useful information for the flexible optoelectronic devices based on graphene transparent electrodes.

  • PDF