A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

방사선 디텍터의 Noise Power Spectrum : II. Spectrum의 평균을 통한 측정 (Noise Power Spectrum of Radiography Detectors: II. Measurement Based on the Spectrum Averaging)

  • 이은애;김동식
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.63-69
    • /
    • 2017
  • NNPS(normalized noise power spectrum)는 획득한 x선 영상에서 평판형 방사선 디텍터의 잡음 특성을 spectrum을 관찰하기 위해 측정한다. 그러나 NNPS 측정은 획득한 영상에 따라 일관적이지 못한 성질을 가지고 있어서 안정된 측정이 필요하다. 디텍터의 NNPS 측정은 표본 periodogram을 구하여 평균을 내는 방법을 사용하는데, 일반적으로 표본의 개수를 충분히 늘리면 정확하면서 안정된 값을 구할 수 있다. 본 논문에서는 periodogram과 같은 표본 spectrum의 평균으로 유한한 개수의 영상이 주어졌을 때 일관적이고 효율적인 NNPS 값을 제공 할 수 있는 두 가지 방법을 제안하고 그 성능을 비교하고 분석했다. 실제 두 종류의 방사선 디텍터로부터 획득한 x선 영상을 사용하여 제안한 방법을 실험하였으며, 주어진 영상을 사용하여 표본 spectrum의 최대 가지 수를 갖는 조합으로 NNPS를 구하고 평균을 내는 방법이 기존 방법에 비하여 안정된 NNPS 측정이 가능함을 보였다.

진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성 (The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging)

  • 박지군;허예지;박정은;박상진;김현희;노시철;강상식
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.35-38
    • /
    • 2009
  • 최근 의료영상분야에서 형광체와 광도전체 물질을 이용한 디지털 평판형 X선 영상검출기가 폭넓게 이용되고 있다. 본 연구는 CsI:Na 형광체층과 광민감도가 우수한 비정질 셀레늄(a-Se)층의 이중 접합구조로 구성된 변환구조 설계를 위한 몬테카를로 시뮬레이션과 X선에 대한 광학적 및 전기적 반응특성을 조사하였다. 먼저 CsI:Na의 발광스펙트럼과 a-Se의 광흡수 스펙트럼을 측정하여 X선에 의한 신호 변환특성을 분석하였다. 또한, 인가전기장의 함수에 따른 X선 민감도을 측정하여 상용화된 a-Se($500{\mu}m$)의 직접변환 검출기와 비교 평가하였다. 측정결과로부터, $10V/{\mu}m$에서 CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) 변환센서의 X선 민감도는 $7.31nC/mR-cm^2$ 이고, a-Se($500{\mu}m$) 검출기는 $3.95nC/mR-cm^2$로 약 2배 정도 높은 값을 보였다.

  • PDF

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작 (The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector)

  • 노시철;강상식;정봉재;최일홍;조창훈;허예지;윤주선;박지군
    • 한국방사선학회논문지
    • /
    • 제6권1호
    • /
    • pp.73-77
    • /
    • 2012
  • 최근 디지털 방사선 영상획득을 위한 평판형 X선 검출기에 이용되는 광도전체(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ 등)에 대한 관심이 증대되고 있다. 본 연구에서는 입자침전법 적용이 가능한 광도전 물질을 이용하여 X선 영상 검출기 적용을 위한 필름층을 제작하여 평가하였다. 먼저, X선 영상에서 일반적으로 사용되는 에너지대역인 70 kVp 의 연속 X선에 대한 필름 두께별 양자효율을 몬테카를로 시뮬레이션을 통해 조사하였다. 평가결과, 현재 상용화된 500 ${\mu}m$ 두께의 a-Se 필름에 대한 양자효율인 64 %와 유사한 $HgI_2$의 필름의 두께는 180 ${\mu}m$ 정도였으며, 240 ${\mu}m$ 두께에서 74 %의 높은 양자효율을 보였다. 입자침전법을 이용하여 제작된 239 ${\mu}m$ 필름에 대한 전기적 측정결과, 10 $pA/mm^2$ 이하의 매우 낮은 암전류를 보였으며, X선 민감도는 1 $V/{\mu}m$의 인가전압에서 19.8 mC/mR-sec의 높은 감도를 보였다. 영상의 대조도에 영향을 미치는 신호 대 잡음비 평가결과 0.8 $V/{\mu}m$의 낮은 동작전압에서 3,125의 높은 값을 보였으며, 전기장의 세기가 높아질수록 암전류의 급격한 증가에 의해 SNR 값이 지수적으로 감소하였다. 이러한 결과는 종래의 a-Se을 이용하는 평판형 검출기를 입자 침전법으로 제작 가능한 필름으로 대체하여 저가형 고성능 영상검출기 개발이 가능할 것으로 기대된다.

디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구 (The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems)

  • 김교태;김금배;강상식;박지군
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.757-763
    • /
    • 2019
  • 최근 넓은 동적 범위 특성을 제공하는 평판 디텍터 개발을 바탕으로 의료보건 환경이 디지털화되고 있는 현 시점에서 적절한 필터 두께의 재설정이 요구되고 있으나, 현 임상에서는 기존 아날로그 시스템에서 연구된 정보를 바탕으로 NCRP에서 제안한 권고 기준을 이용하고 있다. 이에 본 연구에서는 디지털방사선 촬영에서 알루미늄 필터를 이용하여 환자선량 최적화와 더불어 선량크리프의 최소화 가능성을 고찰하였다. 연구 결과, 알루미늄 필터의 두께를 증가함에 따라 유사한 선예도를 가지는 의료영상을 획득 시 피폭되는 피부입사선량을 최대 19.3% 저감할 수 있는 것으로 나타났으나, 영상학적 관점에서 중요한 해상력이 1.01 lp/mm의 큰 변화가 분석되었다. 이러한 해상력의 변화는 X선 빔 경화 현상으로 인하여 피사체에서 발생하는 산란선이 증가하기 때문으로 사료되며, 산란 열화 인자를 통하여 산란선량에 의한 영향이 증가하는 것을 정량적으로 검증하였다. 하지만, 최근 개발되어 광범위하게 적용되고 있는 평판 디텍터는 방사선에 대한 민감도가 높고 넓은 동적 범위 특성을 가지므로 필터 두께에 따라 산란선의 비율에 대한 증가분과 대응하여 적정한 해상력을 유지할 수 있을 것으로 사료되며, 더 나아가 피폭선량 저감을 통해 선량크리프를 최소화 할 수 있을 것으로 기대된다.

X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석 (Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model)

  • 김도일;김성현;호동수;최보영;서태석;이재문;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.202-209
    • /
    • 2004
  • 현재 평판 디텍터를 이용한 디지털 방사선 촬영기술은 방사선 진단 기술 분야에 있어서 매우 중요하고 유용하게 사용되고 있다. 비정질 실리콘 광센서를 사용하는 디지털 방사선 촬영기에는 흡수되는 방사선 에너지를 가시광선으로 변환하는 신틸레이터로 보통 CsI(TI)를 사용한다. 신틸레이터에서 만들어진 가시광선은 이차원 평면으로 구성된 비정실 실리콘 광 다이오드에서 전기적 신호로 전환된다. 좋은 질의 영상을 얻기 위해서는 디지털 방사선 촬영기(Digital Radiography, DR) 디텍터의 방사선에 대한 세부적인 특성 연구가 필수적이다. 이러한 이유로 조사선량과 디지털 방사선 촬영기의 신호의 관계에 대해서 많은 연구가 이루어졌지만 현재까지의 연구에서는 고정된 관전압의 조건에서 두 변수의 관계에 대한 연구가 이루어졌다. 이에 본 연구에서는 X선 스펙트럼 모델인 SPEC-78을 사용하여 조사선량 대신 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호와의 관계를 규명하였다. SPEC-78의 주요 입력변수인 X-ray 튜브의 고유 필터 값을 구하기 위해 조사선량을 측정하여 계산한 조사선량과 비교하였다. 물질에 흡수되는 X-ray의 에너지를 계산하는 알고리즘을 상정하여 디텍터에 흡수되는 에너지를 계산하고 다양한 조건에서 실제 X선 영상의 화소값을 획득하였다. 두변수의 관계를 이용해 특성곡선을 얻었으며 이 결과를 검증하기 위해서 물과 알루미늄으로 제작된 팬텀을 이용하였다. 다양한 조건에서 팬텀 영상의 화소값을 측정하였고 특성곡선과 비교하였다 이러한 과정으로 진행된 연구의 결과로 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호는 거의 선형적임을 알 수 있었다. 또한 팬텀을 이용한 실험에서도 산란된 광자의 영향으로 유발된 약간의 오차에도 불구하고 측정되어진 화소값은 특성곡선과 잘 일치하였다 본 연구를 통해 규명되어진 두 변수의 관계는 예상과 거의 일치하였지만 산란선에 대한 부분은 흡수에너지 계산 알고리즘에서 빠져있어 더 연구가 되어야 할 부분이다. 본 연구를 통해 얻어진 자료들은 디지털 방사선 촬영기의 전처리 과정에 있어서 중요한 정보를 제공할 수 있을 것이라 생각된다.

  • PDF

Investigation of molten fuel coolant interaction phenomena using real time X-ray imaging of simulated woods metal-water system

  • Acharya, Avinash Kumar;Sharma, Anil Kumar;Avinash, Ch.S.S.S.;Das, Sanjay Kumar;Gnanadhas, Lydia;Nashine, B.K.;Selvaraj, P.
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1442-1450
    • /
    • 2017
  • In liquid metal fast breeder reactors, postulated failures of the plant protection system may lead to serious unprotected accidental consequences. Unprotected transients are generically categorized as transient overpower accidents and transient under cooling accidents. In both cases, core meltdown may occur and this can lead to a molten fuel coolant interaction (MFCI). The understanding of MFCI phenomena is essential for study of debris coolability and characteristics during post-accident heat removal. Sodium is used as coolant in liquid metal fast breeder reactors. Viewing inside sodium at elevated temperature is impossible because of its opaqueness. In the present study, a methodology to depict MFCI phenomena using a flat panel detector based imaging system (i.e., real time radiography) is brought out using a woods metal-water experimental facility which simulates the $UO_2-Na$ interaction. The developed imaging system can capture attributes of the MFCI process like jet breakup length, jet front velocity, fragmented particle size, and a profile of the debris bed using digital image processing methods like image filtering, segmentation, and edge detection. This paper describes the MFCI process and developed imaging methodology to capture MFCI attributes which are directly related to the safe aspects of a sodium fast reactor.

롤-투-롤 스퍼터링으로 제작된 Flexible ITO Film의 방사선검출기 적용가능성 연구 (Feasibility as radiation detectors of Flexible ITO film fabricated by roll-to-roll sputtering)

  • 김성헌;이상훈;전승표;박근우;허은실;성한규;박지군;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.374-374
    • /
    • 2010
  • 본 연구는 Roll-to-Roll Sputtering 장비를 사용하여 제작된 Flexible ITO electrode 필름의 방사선 검출기로의 적용가능성을 알아보기 위해 기존의 Glass ITO electrode의 전기적 특성을 비교 평가하였다. 본 연구는 Flexible ITO electrode와 Glass ITO electrode을 하부전극으로 형성하고, 최근에 X-ray 변환체로 활발히 연구되고 있는 Powder 형태의 반도체물질인 HgI2 와 PbI2를 Binder와 일정한 비율로 혼합하여 3-Rolls-Miller를 사용하여 Powder를 일정한 미세크기로 만들고, 대면적 제작이 용이한 Screen-Printing method을 이용하여 시편을 제작하였다. 제작된 필름은 하부전극의 종류에 따른 X-ray 입사 후의 전기적신호의 차이를 측정하고, HgI2와 PbI2 중 Flexible ITO electrode와 더욱 효율적으로 반응하여 기존의 Glass ITO electrode를 대체할 수 있는 전극을 발견하여 진단용 의료영상의 왜곡 현상을 제거할 수 있는 Flexible 방사선 검출기의 제작의 초석을 제공하는 연구를 목적으로 한다. SEM(Scanning Electron Microscope) 통하여 반도체 물질의 결정구조와 크기를 알아보았고, 하부 전극의 종류에 따른 전기적 신호검출을 위해 제작된 필름의 암전류(Dark current) 와 민감도(Sensitivity)를 측정한 후, SNR (Signal -to- Noise)을 계산하여 평가하였다.

  • PDF