• Title/Summary/Keyword: Flat tubular

Search Result 58, Processing Time 0.022 seconds

Experimental study on shear behavior of I-girder with concrete-filled tubular flange and corrugated web

  • Shao, Y.B.;Wang, Y.M.
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1465-1486
    • /
    • 2016
  • Conventional plate I-girders are sensitive to local buckling of the web when they are subjected mainly to shear action because the slenderness of the web in out-of-plane direction is much bigger. The local buckling of the web can also cause the distorsion of the plate flange under compression as a thin-walled plate has very low torsional stiffness due to its open section. A new I-girder consisted of corrugated web, a concrete-filled rectangular tubular flange under compression and a plate flange under tension is presented to improve its resistance to local buckling of the web and distorsion of the flat plate flange under compression. Experimental tests on a conventional plate I-girder and a new presented I-girder are conducted to study the failure process and the failure mechanisms of the two specimens. Strain developments at some critical positions, load-lateral displacement curves, and load-deflection curves of the two specimens have all be measured and analyzed. Based on these results, the failure mechanisms of the two kinds of I-girders are discussed.

Experimental study on innovative tubular web RBS connections in steel MRFs with typical shallow beams

  • Saleh, Aboozar;Zahrai, Seyed M.;Mirghaderi, Seyed R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.5
    • /
    • pp.785-808
    • /
    • 2016
  • An innovative Reduced Beam Section (RBS) connection, called Tubular Web RBS connection (TW-RBS), has been recently introduced and its performance has been numerically investigated in some earlier studies. The TW-RBS connection is a kind of accordion-web RBS connection in which part of the flat web of the beam is replaced by a steel tube at the expected region of the plastic hinge. This paper presents experimental results of three TW-RBS connections under cyclic loading. Obtained results indicated that TW-RBS reduces contribution of the beam web to the whole moment strength and creates a ductile fuse far from components of the beam-to-column connection. Besides, TW-RBS connection can increase story drift capacity up to 9% in the case of shallow beams which is much more than those stipulated by the current seismic codes. Based on the experimental results, the tubular web in the plastic hinge region improves lateral-torsional buckling stability of the beam such that only local buckling of the beam flange at the center of the reduced section was observed during the tests. In order to achieve a better understanding, behavior of all TW-RBS specimens are also numerically investigated and compared with those of experimental results.

Thermal Characteristics of Domestic Solar Collector for Low-Temperature Applications (국내 저온용 집열기의 열성능 특성)

  • Kim, Jeong-Bae;Rhie, Soon-Myeong;Yoon, Eung-Sang;Lee, Jin-Kook;Joo, Moon-Chang;Lee, Dong-Won;Kwak, Hee-Youl;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.155-160
    • /
    • 2007
  • This study shows the results on thermal performance test with domestic solar collector for low-temperature applications using KS, then reveals the efficiency difference between KS and EN standard. Using the test results, this study Presents the status of thermal performance with domestic solar collector including flat-plate, single evacuated, and double evacuated (with mirror or U-tube) solar collector.

Fabrification of Segmented Flat-Tubular SOFC cell (Segmented 평관형 SOFC 셀 제조)

  • Park, Sung-Tae;Choi, Byung-Hyun;Ji, Mi-Jung;Choi, Heon-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.137.1-137.1
    • /
    • 2010
  • SOFC cell 하나의 전위차는 약1.1V이기 때문에 발전용으로 사용하기 위해서는 수많은 단전지를 직렬로 연결하는 구조가 필요하다. 이러한 stack의 디자인에서 발생하는 문제를 획기적으로 개선한 형태가 하나의 지지체에 셀을 직렬로 연결함으로 전극의 선폭 및 단위 셀 간의 간격이 기존 평판형, 원통형에 비해 대폭 축소되어 전극 및 연결재의 저항손실을 최소화할 수 있는 Segmented형 SOFC이다. Segmented SOFC에 적용하기 위한 세라믹 다공성 지지체는 연료와 공기에서의 화학적 안정성, 셀의 구성소재와 반응이 없으며 열팽창계수가 유사해야하는 특성을 가져야하는데 그 중에서도 지지체로써 적절한 기계적 강도와 높은 가스투과도가 요구되어진다. 본 연구에서는 고온에서 안정한 Spinel의 MgAl2O4를 주성분으로 하는 다공성 지지체를 압출 성형하여 평관형으로 제조하였으며 활성탄을 기공형성제로 사용하여 연료의 공급이 원활하도록 약 30%의 기공율을 가지는 다공성 세라믹 지지체를 제조하였다. 제조된 세라믹 지지체에 연료극(NiO/YSZ), 전해질(TZ8Y), 공기극(LSM)을 코팅하여 실제 SOFC에 적용이 가능함을 확인하였다.

  • PDF

FATIGUE DESIGN OF BUTT-WELDED TUBULAR JOINTS

  • Kim, D. S.;S. Nho;F. Kopp
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.127-132
    • /
    • 2002
  • Recent deepwater offshore structures in Gulf of Mexico utilize butt welded tubular joints. Application of welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical because the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimating the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves specified in the codes and standards. Applying the stress concentration factor of the welded structure to S-N approach often results in very conservative assessment because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fracture mechanics and fitness for service (FFS) technology have been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves to be used and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. An attempt was made to develop set of S-N curves based on fracture mechanics approach by considering non-uniform stress distribution and a threshold stress intensity factor. Series of S-N curves generated from this approach were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02"). Similar comparison with API X′ was made for tubular joint.. These initial crack depths are larger than the limits of inspection by current Non-destructive examination (NDE) means, such as Automatic Ultrasonic Inspection (AUT). Thus a safe approach can be taken by specifying acceptance criteria that are close to limits of sizing capability of the selected NDE method. The comparison illustrates conservatism built into the S-N design curve.

  • PDF

A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test (태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구)

  • Kim, Mi-Yeon;Choi, Byung-Do;Kim, Hyung-Geun;Park, Jin-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

Application Performances of the Simplified Solar Collectors and for the Drying of Red Pepper (간이(簡易) 태양열(太陽熱) 집열기(集熱器)의 유형별(類型別) 분석(分析) 및 고추건조(乾燥)에의 이용(利用))

  • Choi, Boo-Dol;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.479-484
    • /
    • 1986
  • Two different types of solar collector for farm dryer- the flatplate type and the modified tubular type-were constructed and analyzed on their performances. The transparent plastic film, black painted galvanized iron sheet and black vinyl film were used for the cover and absorber of the flat-plate types. The simplified tubular type was constructed with transparent films for the cover and black vinyl films for the absorber Two elliptical iron rings were used to form a tubular shape through which air could pass. No remarkable differences were found in thermal efficiences between the absorbers made with galvanized iron sheet and black vinyl film. The average thermal efficiencies of the solar collectors were 42.8%(max.48.2%, min.38.2%) for flat plate type and 22.971 (max. 25.4%, min. 14.8%)) for tubular one. The empirical equations were proved to be applicable to the prediction of temperature elevation. The tubular solar heat collector was successfully applied to red peppers drying as a practical farm dryer. The drying rate was almost doubled compared to a conventional sun drying.

  • PDF

Skeletal Sarcomas Examined with MR in Tubular and CT in Flat Bones (골격계 육종에서 관상골MR과 편평골CT의 유용성)

  • Moon, Tae-Yong;Lee, Young-Joon;Jung, Kyung-Hwa;Hur, Jin-Do;Sol, Mi-Young;Kwon, Woon-Jung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.162-168
    • /
    • 2003
  • Purpose: Primary malignant bone tumors are classified with mesenchymal sarcomas (MS) such as osteosarcoma and chondrosarcoma and small round cell sarcomas (SRS) such as Ewing's sarcoma and lymphoma. Radiological examinations for skeletal sarcoma were using MR scan in tubular bone sarcomas and CT scan in flat bone sarcomas recently. Both MR and CT scans show some findings of bone destruction and soft tissue mass but MR scans don't reveal a finding with mineralization relatively. So we investigated bone destructive pattern of skeletal sarcomas on both MR and CT scans for differentiation of MS and SRS. Materials and Methods: There are 28 MS and 26 SRS examined with MR or CT scans. The findings according to bone destructive pattern were divided to eccentric and concentric in 26 cases of tubular bone sarcomas with MR scan and 28 cases of flat bone sarcomas with CT scan. Results: MR images revealed eccentric destruction in 12 cases of 16 MS and concentric in all cases of 10 SRS (p>.01). CT images showed eccentric destruction in 10 cases of 12 MS and concentric bone destruction in 13 cases of 16 SRS (p>.01) Conclusion: The findings divided to eccentric and concentric bone destructive patterns were useful for differential diagnosis of MS from SRS on both MR and CT scans.

  • PDF

Punching Shear Strength of CFT Column to RC Flat Plate Connections Reinforced with Shearhead (전단머리 보강 CFT기둥-RC 무량판 접합부의 펀칭전단강도)

  • Kim, Jin-Won;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.423-433
    • /
    • 2012
  • This paper summarizes full-scale gravity-load test results on CFT column-to-RC flat plate connections reinforced with shearhead. CFT construction has many structural and constructional advantages over conventional steel and RC column construction and is gaining wide acceptance. Meanwhile the use of RC flat plate system in the basement and residential floors of tall buildings is often mandatory to reduce story height and enable rapid construction in domestic practice. Combining CFT column and flat plate floor is expected to result in further rapid construction. However, the issues related to connecting CFT column to RC flat plate have not been fully addressed yet. Several promising connecting schemes by using steel shearhead were proposed and tested in this study. Test results showed that the proposed connection can exhibit the punching shear strength higher than RC flat plate counterparts. An empirical formula that can reasonably predicts the punching shear strength of the proposed connection was also proposed.