• 제목/요약/키워드: Flat plate

검색결과 1,234건 처리시간 0.026초

CFD를 이용한 OSRVM 주변의 공력소음 해석과정 개발 및 검증 (Development of Wind Noise Analysis Procedure and Its Verification Using CFD Tool around an OSRVM)

  • 박현호;한현욱;김문상;하종백;김용년
    • 한국자동차공학회논문집
    • /
    • 제20권4호
    • /
    • pp.92-102
    • /
    • 2012
  • The process of the wind noise analysis around an OSRVM is developed and is verified by simulating unsteady flow field past a generic OSRVM mounted on the flat plate at the Reynolds number of $Re_D=5.2{\times}10^5$ based on the mirror diameter. The transient flow field past a generic OSRVM is simulated with various turbulence models, namely DES-SA, LES Constant SGS, and LES Dynamic SGS. The sound radiation is predicted using the Ffowcs- Williams and Hawkings analogy. For the present simulation, the 6.35million cells are generated. Time averaged pressure coefficients at 34 locations on the surface of the generic OSRVM are compared with the available experimental data. Also, 12 Sound Pressure Levels located on the surrounding mirror are compared with the available experimental data. Both of them show good agreements with experimental data.

Effects of frequency ratio on bridge aerodynamics determined by free-decay sectional model tests

  • Qin, X.R.;Kwok, K.C.S.;Fok, C.H.;Hitchcock, P.A.
    • Wind and Structures
    • /
    • 제12권5호
    • /
    • pp.413-424
    • /
    • 2009
  • A series of wind tunnel free-decay sectional model dynamic tests were conducted to examine the effects of torsional-to-vertical natural frequency ratio of 2DOF bridge dynamic systems on the aerodynamic and dynamic properties of bridge decks. The natural frequency ratios tested were around 2.2:1 and 1.2:1 respectively, with the fundamental vertical natural frequency of the system held constant for all the tests. Three 2.9 m long twin-deck bridge sectional models, with a zero, 16% (intermediate gap) and 35% (large gap) gap-to-width ratio, respectively, were tested to determine whether the effects of frequency ratio are dependent on bridge deck cross-section shapes. The results of wind tunnel tests suggest that for the model with a zero gap-width, a model to approximate a thin flat plate, the flutter derivatives, and consequently the aerodynamic forces, are relatively independent of the torsional-to-vertical frequency ratio for a relatively large range of reduced wind velocities, while for the models with an intermediate gap-width (around 16%) and a large gap-width (around 35%), some of the flutter derivatives, and therefore the aerodynamic forces, are evidently dependent on the frequency ratio for most of the tested reduced velocities. A comparison of the modal damping ratios also suggests that the torsional damping ratio is much more sensitive to the frequency ratio, especially for the two models with nonzero gap (16% and 35% gap-width). The test results clearly show that the effects of the frequency ratio on the flutter derivatives and the aerodynamic forces were dependent on the aerodynamic cross-section shape of the bridge deck.

개수로의 유량 측정을 위한 제형 Cutthroat Flume에 관한 연구 (A Study on the Trapezoidal Cutthroat Flumes for Measuring Flow in Open-Channels)

  • 윤주상;정하우
    • 한국농공학회지
    • /
    • 제19권4호
    • /
    • pp.4533-4543
    • /
    • 1977
  • The purpose of this study was to investigate and compare flow discharges of rectangular, V-notch and trapezoidal type of cutthrooat flumes, and the published data for trapezoidal parshall flumes. And the trapezoidal cutthroat flumes were also compared in their accuracy of discharge measurements for various convergence ratios in the inlet section and divergence ratios in the outlet section. Five flumes were studied, and all the flumes were 45cm long with flat-bottom and were made of well-finished transparent acryl plate of 3mm thickness. One rectangular, one V-notch and three trapezoidal types were numbered 1 to 5 as shown in Fig. III-1. The measured depth of water was ranged from 5 to 20cm. The results obtained in this study are summarized as follows: 1. The general discharge equations for tested prototypes are listed for free flow in Table IV-1 and for submergence flow in Table IV-4. 2. In both free and submerged flow, the accuracy of the discharge formula obtained by this test is highly significant at 1% level as shown in Table IV-2 and Table IV-6. The accuracy of disharges measured depends upon the convergence and divergence ratios in the trapezoidal types: the less the ratios of convergence as well as divergence, the lower the accuracy. 3. Submergence ratios tend to increase in the order of flume number except flume No. 4. This implies that trapezoidal cutthroat flumes are more acceptable than rectangular or V-notch ones for free flow. 4. The transition submergence for the trapezoidal Parshall flumes ranges from 80-85 percent, which is slightly higher than the tested flume. However, the trapezoidal cutthroat flume No. 5 has higher transition submergence ratio, ranging from 73-78 percent, than other trapezoidal ones. The difference between the trapezoidal Parshall flumes and the trapezoidal cutthroat flumes in transition submergence seems small enough to be ignored in their field use. 5. Trapezoidal cutthroat flume is simple and economical to construct in existing openchannels whose shapes are generally trapezoidal. In order to obtain the best rating accuracy, flume No. 3 among the tested trapezoidal types is recommended, because it shows the highest accuracy for both free and submerged flow.

  • PDF

소형 연소기를 위한 재생냉각의 선행연구 (Preliminary Research of Regenerative Cooling for Small Scale Combustors)

  • 장동욱;조성권;조황래;방정석;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.163-170
    • /
    • 2011
  • 2,500 N급 과산화수소/케로신 이원 추력기의 성능 향상 및 다양한 임무에 적용하기 위하여 재생냉각의 적용가능성을 검토하였다. 1-D 계산을 통해 과산화수소를 냉각제로 하는 경우에 대한 계산을 수행하였다. 설계된 재생냉각 연소기의 노즐 목에서의 열 유속은 18~20 $MW/m^2$ 로 예측되었으며, 그에 따른 유로의 너비는 2.5 mm 높이는 0.45 mm로 설계 되었다. 설계된 유로형상을 바탕으로 냉각 유로 내에서의 압력강하를 예측하기 위한 평판형 모델을 제작하여 실험을 진행하였고, 수치해석결과와 비교를 수행하였다. 그 결과, 수치해석과 실험결과와의 최대 오차는 약 13%, 평균 오차는 약 5%로 계산되었다.

  • PDF

태안 시설원예단지의 온실 냉난방 부하 분석 (Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean)

  • 서원명;배용한;허해준;곽철순;이석건;이종원;윤용철
    • 한국농공학회논문집
    • /
    • 제51권6호
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

사각단면을 갖는 환경 거칠기 요소의 거칠기 간격에 따른 유동 변화 (제1보: 평균유동장) (Turbulent Flow over 2-D Rectangular-Shaped Roughness Elements with Various Spacings(Part 1 : Time Averaged Flow))

  • 현범수;서은정;김무롱;최기철
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권2호
    • /
    • pp.79-84
    • /
    • 2006
  • 본 연구는 자연지형에 존재하는 다양한 형태의 크고 작은 거칠기 요소들로 인해 기본 유동장이 변화하는 양상을 밝히기 위한 기초연구로서, 본 제1보와 이어지는 제2보로 나뉘어 소개될 것이다. 실험은 동일한 2차원 사각단면을 갖는 많은 양의 거칠기 요소를 평판위에 규칙적으로 배열한 후 거칠기 주위 유동장을 계측하였다. 회류수조에서 PIV 기법을 사용하여 2종류의 거칠기요소 높이와 3종류의 거칠기 사이 간격을 택하여 총 6경우에 대하여 거칠기 유동의 특성을 비교하였다. 실험결과 거칠기 간격이 거칠기 높이의 7배와 14배인 경우가 3.5배에 비하여 거칠기로 인한 유통장의 교란이 더 활발하고, 그에 따라 유동장에 미치는 영향도 큼을 확인할 수 있었다.

  • PDF

사각단면을 갖는 환경 거칠기 요소의 거칠기 간격에 따른 유동 변화(제2보 : 난류, 마찰속도 및 적분변수) (Turbulent Flow over 2-D Rectangular-Shaped Roughness Elements with Various Spacings(Part 2 : Turbulence, Friction Velocity and Integral Parameters))

  • 현범수;서은정;문재승;김길원
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권2호
    • /
    • pp.85-91
    • /
    • 2006
  • 본 연구는 자연지형에 존재하는 다양한 형태의 크고 작은 거칠기 요소들로 인하여 기본 유동장이 변화하는 양상을 밝히기 위한 연구로서 회류수조에서 PIV 기법을 사용하여 수행되었다. 먼저 제1보에서는 동일한 2차원 사각단면을 가지는 많은 양의 거칠기 요소를 평판위에 규칙적으로 배열한 후 거칠기요소의 높이와 거칠기 사이의 간격이 다른 세 경우에 대하여 유속, 유선 및 와도분포를 계측하여 거칠기 유동의 특성을 살펴보았다. 본 2보에서는 난류유동특 성을 비롯하여 벽법칙을 이용한 해석과 경계층 적분변수 도출을 통하여 거칠기 간격이 유동장 변화에 미치는 영향을 정량적으로 비교하고자 하였다. 실험결과 거칠기 간격이 거칠기 높이의 7배와 14배인 경우 3.5배에 비하여 거칠기로 인한 유동장의 변화가 큼을 재차 확인할 수 있었다.

  • PDF

선저부 공기공동을 이용한 실선선형의 저항성능 개선을 위한 선저형상 개량연구 (On the Suitable Shape of Bottom for the Application of Air Cavity on Hull Bottom to the Practical Hull Form)

  • 고석천;김효철
    • 대한조선학회논문집
    • /
    • 제36권3호
    • /
    • pp.1-7
    • /
    • 1999
  • 본 논문에서는 충주호에서 유람선으로 사용되고 있는 광폭천흘수형 선박을 대상으로 선정하고, 공기를 공급하여 선저에 공동을 형성시켜 마찰저항을 감소시킬 수 있도록 선박의 선저형상을 개량하였다. 2차원 공동문제로 이상화하여 선저에 부착되는 공동을 이론적 방법으로 수치해석하여 공기공동의 형상과 내부압력을 추정하였고 공동현상을 지배하는 무차원수를 살펴보았다. 예인수조에서 모형선실험을 시행하고 단의 높이변화, 선측의 공기유출막이벽 등에 의한 공기공동의 형성과 저항감소효과를 조사하였다. 또한 투명한 아크릴로 제작된 선저부를 통해, 선저에 부착되는 공기공동의 발달과정을 관측하였다. 이러한 연구를 통하여, 실선선형의 선저부 형상을 적절히 개량하고 공기를 공급함으로써 설계속도 부근에서 원래선형의 전저항의 25%정도를 줄일 수 있음을 모형선에서 확인하였다.

  • PDF

평지붕 설치 태양광시스템의 표면형태 조사·분석 (Investigation and Analysis on the Surface Morphology of Roof-Top Photovoltaic System)

  • 이응직
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.57-65
    • /
    • 2016
  • Domestic photovoltaic system for roof-top is installed towards the south at an angle of 20 to 35 degrees and the shape of PV array is divided into two kinds; a plane shape and a curved shape. This paper aims to understand an actual condition of PV facility and strengths and weaknesses of support structure production and installation and to consider the best PV surface shape by analyzing theoretical logics of these two surface shapes and architectural perspective-based realistic case studies. This study targeted 98 facilities including common houses, public institutions and education institutions. In common houses, all of 59 PV facilities have a plane surface. In public institutions, 7 of 15 PV facilities have a curved array surface and 8 PV facilities have a plane surface. In education institutions, also, 14 of 24 PV facilities have a plane array surface and 10 PV facilities have a curved surface. Most of 98 facilities have a flat roof supporting shape. However, it was found that the curved shape wasn't positive for PV generation due to the change of radial density and it was at least 10 % more expensive to produce its structure. Also, domestic general large single-plate PV facilities have problems of harmony with buildings and wind load. Therefore, it is considered that for fixed-type roof-top PV, a plane PV array shape is good for optimum generation and economic efficiency and a parallel array structure on the roof surface is favorable to wind load and snow load without being a hindrance to the building facade.

200kW 탑형 태양열발전시스템의 Heliostat Field 설계 (Design of Heliostat Field for 200kW Tower Type Solar Thermal Power Plant)

  • 박영칠
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.41-51
    • /
    • 2012
  • Heliostat field is the most important subsystem in the tower type solar thermal power plant since its optical performance affects the total system efficiency most significantly while the construction cost of it is the major part of total construction cost in such a power plant. Thus a well designed heliostat field to maximize the optical efficiency as well as to minimize the land usage is very important. This work presents methodology, procedures and result of heliostat filed design for 200kW solar thermal power plant built recently in Daegu, Korea. A $2{\times}2(m)$ rectangular shaped receiver located at 43(m) high and tilted $28^{\circ}$ toward heliostat field, 450 of heliostats of which the reflective surface is formed by 4 of $1{\times}1(m)$ flat plate mirror facet, and the land area having about $140{\times}120(m)$ size are used to form the heliostat field. A procedure to deploy 450 heliostats in radial staggered nonblocking formation is developed. Also the procedures to compute the cosine effect, intercept ratio, blocking and shading ratio in the field are developed. Finally the heliostat filed is designed by finding the optimal radial distance and azimuthal spacing in radial staggered nonblocking formation such that the designed heliostat field optical efficiency could be maximized. The designed heliostat field has 77% of annual average optical efficiency, which is obtained by annually averaging the optical efficiencies computed between the time of where sun elevation angle becomes $10^{\circ}$ after sunrise and the time of where sun elevation angle becomes $10^{\circ}$ before sunset in each day.