• 제목/요약/키워드: Flat lighting device

검색결과 7건 처리시간 0.034초

천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구 (A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System)

  • 김미희;태원진
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

유리도광체를 이용한 평판조명용 광확산패턴의 최적설계 연구 (Study of Optimal Light Scattering Pattern Design for Flat Lighting Device using Glass Light Guide)

  • 한정민;김원배
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.242-246
    • /
    • 2017
  • In this study, it was investigated about optical simulation in high brightness and high uniformity general lighting using glass light guide plate. And we adopt edge-light emission type light plate. Edge-light type lighting has been used LCD application, especially note PC or smart phone backlight unit. Because it had the good properties such as slim shape and light weight. We thought this type was suitable for general lighting application such as wall attached type or ceiling mount type. But many of edge-light type lighting had problems. It called slanted output light rays. That was main key parameter how could control the direction of output light rays. We investigated the solution of this problems, using ray tracing method, we recognized the major fact of the solution relied on the geometric structure of diffusing dot shape. We set the conditions of aspect ratio in diffusing dot shape such as 0.5 to 1. And, at first, we designed diffusing dots shape based on the results of optical simulation and made specimen. as above condition, and acquired good result in confirming dots shape such as the value of the output rays's peak angle was around 75 degrees. And good light distribution characteristics were measured by slated spectro-radiometer. It was shown that the effective ways of designing light distribution characteristics using optical simulation such as ray tracing linear method for making general lighting using glass light guide plate.

Advances in $Plexcore^{TM}$;Technology for Printed Electronic Devices

  • Hammond, Troy;Williams, Shawn
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1666-1669
    • /
    • 2006
  • Plextronics develops conductive polymer technology (trademarked $Plexcore^{TM}$) that will enable the broad market commercialization of printed electronic devices. This talk will emphasize advances to our $Plexcore^{TM}$ HIL technology - a soluble non-acidic hole injection layer (HIL) technology for OLEDs . which is designed to dramatically improve device efficiency and lifetime of flat panel displays and solid state white-lighting.

  • PDF

Polymer Light-Emitting Diode with Controlled Nano-Structure

  • Park, O-Ok;Lim, Yong-Taik;Park, Jong-Hyeok;Lee, Ho-Chul;Kim, Tae-Ho;Lee, Hang-Ken
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.194-194
    • /
    • 2006
  • Polymer light-emitting diodes(PLEDs) have great potential application in large area flat panel displays and general lighting so intense academic and industrial research, and impressive scientific and technological progress has been achieved in this field. However, the efficiency and stability of PLEDs till need to be improved in order to fully realize the advantages of low cost and ease of fabrication provided by organic materials. Here, we report our effort to enhance the PLED' s performance in two approaches : 1) Utilizing nano-structured materials such as nano particles, clay, nano porous silica in active layer 2) Modifying the device structure in nano scale to improve not only the device efficiency but also its stability.

  • PDF

종합병원 병실 내 광선반과 블라인드 설치 방식에 따른 자연채광 유입 효과 연구 (A Study on the Effect of inflow Daylight according to the installation method of controlling Light Shelf and Blind in the Room of General Hospital)

  • 조주영;이효원
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.3-10
    • /
    • 2013
  • This study aims to identify convenient surrounding of the hospital room to be improved by specifically focusing on light environment and to examine a change of inflow of the daylight in the hospital room by using blind and light shelf device as base data of preliminary research for comprehending the relationship between healing environment and natural day light. Simulation analysis on previous facilities and the installation of horizontal light shelf that derives the inflow of day light has been specifically referred by using ECOTECT2011 program. In case of C-facility that mostly adjoined to exterior spaces, it was shown to be closer to a proper uniformity factor when an angle was controlled on the light shelf with blind installed at the same time. However, it was not overall appropriate because of visual displeasure occurred from inflow of much day light. In conclusion, it is the form of flat surface such as H-facility that provides an effect after installing the device to derive day light. Especially, it was shown that interior day light environment was improved when installing blind and controlling the angle at the same time.

FPD 공정을 위한 램프하우스 열전달 특성 연구

  • 김태안;서원호;김준현;김윤제
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 추계학술대회 발표 논문집
    • /
    • pp.132-137
    • /
    • 2006
  • With the help of the development of digital-multimedia in the middle of 1990's, FDP(Flat Panel Display) had attracted considerable attention. Collimation proximity exposure system that transfers the pattern on wafer or glass exactly using mask and light with appropriate wavelength is core process in semiconductor and liquid display element. The performances of resolution required in precision exposure system are evaluated by resolving power, depth of focus and storage area. Most of development has targeted on these three factors. The optical design including lamp house has played an important role on the performance of exposure process. In this study, we evaluate the cooling system, concerning on exposure device with mercury lamp among the kernel equipment for the production of LCD, to prevent the instability of lighting due to long term accumulation of excessive heating inside the lamp house. Numerical analysis is conducted on full-scale model. The characteristics of three-dimensional flow, pressure and temperature distribution on exposure system are graphically depicted to estimate the whole cooling system for lamp house and to establish the design criteria.

  • PDF

AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석 (Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report)

  • 정해조;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.77-82
    • /
    • 2006
  • 영상의 표시는 PACS 및 디지털 의료 영상계에서 중요한 요소이다. 동일한 디지털 데이터에 대한 영상의 질은 디스플레이 장치의 물리적 특성, 최적화된 설정 및 교정, 주위 불빛 조건 등에 의하여 영향을 받는다. 디스플레이 장치는 사용시간에 따라서 휘도 감소 및 설정값들의 변화에 의하여 성능이 저하된다. 디스플레이 시스템의 성능이 지속적으로 저하되기 때문에 일정한 주기마다. 정도관리를 수행하여야한다. 정도관리 효과를 평가하기 위하여 진단에 사용되는 10대의 평판 LCD 디스플레이 장치를 선택하였으며, 설정값 교정 전과 후에 휘도 반응, 휘도 공간 의존도, 분해능, 그리고 색도 변화를 정량적으로 측정하여 평가하였다. 정도관리 효과는 휘도 반응과 휘도 공간 의존도 테스트에서 다소 큰 변화가 있었으나 분해능 및 디스플레이 색도에서의 영향은 크지 않았다. 디스플레이 장치의 주기적인 정도관리는 의료영상을 일관성 있게 표시하기 위하여 필수적이다. 본 연구 결과는 의료용 디스플레이 장치의 정도관리에 대한 항목 선정 및 주기를 결정하는 데 중요한 역할을 할 수 있을 것이다.

  • PDF