• Title/Summary/Keyword: Flat Spot

Search Result 59, Processing Time 0.03 seconds

Design of flat-field XUV spectrograph with a toroidal mirror (광집속 Toroidal mirror를 이용한 평면결상)

  • 이병훈;최일우;남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.77-85
    • /
    • 1992
  • The design of a flat-field XUV spectrograph is optimized for a high throughput, aberration-corrected spectral image in the wavelength region of 50-300 $\AA$ The varied-line spacing (VLS) concave grating theory for an XUV spectrograph with a toroidal mirror in front of an entrance slit is derived. Since the derived theory includes the arbitrary shaped source, it is able to correct the limit of the simple optimization theory which considers only a point source at the center of the entrance slit. The reflection matrix at the toroidal mirror and the diffraction matrix at VLS grating are derived and compared with those of a holographic grating. The absolute energy efficiency of a flat-field spectrograph is calculated by considering the reflectivities of the toroidal mirror and the Au coated concave grating and the grating efficiency. The alignment sensitivity of the toroidal mirror and the concave grating is investigated, and the method to achieve the best imaging of XUV spectrum is discussed. The calculated resolving power of the flat-field XUV spectrograph is more than 4000 in the aberration-corrected wavelength range. The focused spot size at the dispersion plane is less than $20\mu \textrm m\times \mu \textrm m$at the wavelength 100$\AA$ It is shown that a high throughput characteristic can also be achieved through a careful adjustment of alignment parameters.

  • PDF

Cloning and Purification of Envelope Proteins (VP19, VP28) and Nucleocapsid Proteins (VP15, VP35) Genes of a Shrimp White Spot Syndrome Virus Isolates in Korea

  • Seok, Seung-hyeok;Park, Jae-hak
    • Proceedings of the Korean Society of Veterinary Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.41-41
    • /
    • 2003
  • White spot syndrome virus (WSSV) is the causative agent of a disease that has led to severe mortalities of cultured shrimps in Korea and many other countries. Since 1993, massive mortalities due to the viral infection have also occurred in the penaeid shrimps cultured in Korea. WSSV is a large, circular, double stranded (ds) DNA virus and an enveloped, ellipsoid virus with a rod-shaped nucleocapsid with flat ends. In order to identify the characteristics of this Korean isolate of WSSV, the genes for four virion proteins, VP15, VP19, VP28 and VP35 were cloned and their sequences were compared with the available pool of WSSV gene sequences in the GenBank/EMBL databases. From these comparisons, we confirm the occurrence of WSSV in Korea and deduce that, VP15, VP28 and VP35 genes are identically conserved among the Korean isolate and geographically different foreign isolates, but VP19 amino acid sequences of the Korean WSSV isolates changed valine of the foreign isolates into aspartate. (omitted)

  • PDF

Study of Optical Design Method for Ultra Slim Backlight System Using LED Light Source (LED광원을 이용한 초박형 백라이트에 대한 광학설계기법의 연구)

  • Han, Jeong-Min;Han, Jin-Woo;Kim, Byoung-Young;Kim, Jong-Yeon;Kim, Young-Hwan;Kim, Jong-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.432-432
    • /
    • 2007
  • We studied optical simulation method for ultra slim backlight system. We designed 0.7mm thickness light guide plate and combined 48 white color LEDs for 12 inch wide size TFT-LCD. We designed flat shape PMMA light guide plate with both side patterned. It have vertical prism shape on upper side and ellipse dot pattern on the other side. We targeted 4500 nit brightness and uniform emission characteristic without hot spot or dark area. At first, we designed uniform emission area with more high brightness in center area and then, debugged light entering hot spot zone and direction of outgoing light flux. Although it was designing step, we obtained good result with reverse prism optical sheet and it had good repeatability because it was based on the stamper method in injection process without laser engraving or micro groove engraving method.

  • PDF

Age and Growth of the Blue Spot Mudskipper (Boleophthalmus pectinirostris) in the Mud Flat of Southwestern Korea (한국 남서 갯벌지역 짱뚱어 (Boleophthalmus pectinirostris)의 연령과 성장)

  • JEONG Sun Jae;HAN Kyeong Ho;KIM Jin Koo;SIM Doo-Saing
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.1
    • /
    • pp.44-50
    • /
    • 2004
  • Age and growth of the blue spot mudskipper (Boleophthalmus pectinirostris) were studied using the samples caught in the mud flats of southwestern Korea during April-October, 2001. The value of the marginal index of the second actinost bone was the lowest in July and October and indicated by rings that was analysis of formed teice a year. The relationship between body weigt (BW) and total length (TL) was expressed as BW=0.000005 $TL^{3.12}\;(r^2=0.92)$ for females and BW=0.000476 $TL=^{2.18}\;(r^2=0.62)$ for males. Regression analysis of TL-BW between sexes showed a significant difference (P<0.01). Relationship between total length (TL) and actinost radius (R) were expressed as TL=16.9+33.4 R $(r^2=0.62)$ for females and TL=45.8+26.2 R $(r^2=0.41)$ for males. Growth parameters, $L\infty,t_0$ and K were estimated as 165.2 mm, -0.23, and 1.07 for females and 155.3 mm, -0.35, and 1.39 for males.

Local Deformation Based Design Concept for Multi-layered Pipeline (국부 변형을 고려한 다중관 설계 기법)

  • Won, Jong-Hwa;Kim, Moon-Kyum;Kim, Kyu-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.570-573
    • /
    • 2011
  • 본 논문에서는 배관의 국부변형을 고려하여 각 배관의 특성으로 인하여 발생하게 되는 최대 응력 발생지점에 대한 평가 및 설계기법을 제안한다. 다중관은 일반적으로 배관의 매설 조건이 불안정한 곳이나 배관의 내부 유체의 유출 모니터링 및 난방관 등의 보온을 목적으로 사용되나, 다중관의 거동에 대한 거동 및 설계에 대한 연구는 미비한 실정이다. 본 연구에서 제안한 기법은 탄성범위에서 거동하는 연성관을 대상으로 하며 외관의 형상 및 외부 하중에 의하여 예상되는 국부 변형을 설계 인자로 고려하는 방법이다. 일반적인 원형관의 경우 관의 하단부에서 가장 큰 국부 변형 반경을 나타나며, 국내외에서 사용하고 있는 정사각 콘크리트 보호공의 경우 관의 상측, 하측부($45+90n^{\circ}$)에서 가장 큰 반경을 관찰할 수 있다. 이는 내압이 작용하는 구조물에 대하여 낮은 압력에도 항복에 이르는 환경을 제공하기 때문에 설계 시 반영되어야 할 중요한 요소이다.

  • PDF

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF

Design and fabrication of a holographic scanner using the ray tracing method (광선 추적을 이용한 홀로그래픽 스캐너의 설계 및 제작)

  • 김종재;정만호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.107-113
    • /
    • 1999
  • Low-aberration holographic scanners that eliminate the need for lenses and mirrors promise to greatly reduce the cost of laser printers and image scanners. In this study, a holographic optical element that can simultaneously scan and focus a laser beam is designed with analytic ray tracing method. An analytic and experimental work is conducted in which we investigated the hologram structure and hologon configuration for linear aberration-free scanning. For a prototype scanner, a He-Ne laser is used to manufacture and reconstruct the hologram, and the measured bow is about $\pm$133$\mu\textrm{m}$ and spot size(half-intensity beamwidth) in under 100$\mu\textrm{m}$ for a 300 mm scan length without using a correcting lens or mirror. The diffraction efficiency is about 55$\pm$5%, which is acceptably flat. The experimentally measured results agrees with the computed values. From this fact, we can conclude that the computed results using ray tracing method are practical and useful values, and have a potential for use in high resolution laser printers.

  • PDF

A Study of Types and Forms of Branch-road in Traditional Korean Villages (한국전통마을에 있어서 갈림길의 유형과 형태에 관한 연구)

    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.1
    • /
    • pp.101-109
    • /
    • 1999
  • The purpose of this study is to analyse types and forms of branch-road in traditional korean villages. To do this, this study has selected and measured 87 branch-road cases of five traditional villages. An analysis of the case study has revealed the following results : 1. Branch-roads have four formations : 3 way, 4 way, multi-way and others. 2. Branch-roads comprise 64 percent of 3 way, 18 percent of 4 way, 8 percent of multi-way and 9 percent of others, respectively. 3. Topographic conditions have mostly affected the formation of branch-roads. 3 way of branch - roads are easily found in flat village. 4 way are multi-way of branch-road are found in semi-hilly and hilly village 4. 3 way of branch-roads have three types: T-type, Y-type, and y-type. 5. T-types are easily found in flat village, but Y-type and y-type are found in semi-hilly and hilly village. 6. Each angle of T-type is 171,99,90, respectively. It has turned out 8 degree is slightly deviated form the square. 7. Y-type of branch-road has an asymmetric form, comprising 145, 128, 87 degree of the angle, compared to 150, 150, 60 degree of symmetric one. 8. Average angles of y-type that are mostly found in hilly village are 175, 113, 72. Angle differences from each spot are 62 and 41 degree. It is assumed that 39 degree is a slope of least effort to walk. 9. 4 way of branch-roads have not only "+" type but various types of K, Y and Y, Y and y, T and y and a foot of bird. 10. It is assumed that multi-way of branch-roads, mostly found on the middle and bottom of the hilly slope, has naturally formed to connect up and down, left and right.and right.

  • PDF

Preflight Calibration Results of Wide-Angle Polarimetric Camera (PolCam) onboard Korean Lunar Orbiter, Danuri

  • Minsup Jeong;Young-Jun Choi;Kyung-In Kang;Bongkon Moon;Bonju Gu;Sungsoo S. Kim;Chae Kyung Sim;Dukhang Lee;Yuriy G. Shkuratov;Gorden Videen;Vadym Kaydash
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.293-299
    • /
    • 2023
  • The Wide-Angle Polarimetric Camera (PolCam) is installed on the Korea's lunar orbiter, Danuri, which launched on August 5, 2022. The mission objectives of PolCam are to construct photometric maps at a wavelength of 336 nm and polarization maps at 461 and 748 nm, with a phase angle range of 0°-135° and a spatial resolution of less than 100 m. PolCam is an imager using the push-broom method and has two cameras, Cam 1 and Cam 2, with a viewing angle of 45° to the right and left of the spacecraft's direction of orbit. We conducted performance tests in a laboratory setting before installing PolCam's flight model on the spacecraft. We analyzed the CCD's dark current, flat-field frame, spot size, and light flux. The dark current was obtained during thermal / vacuum test with various temperatures and the flat-field frame data was also obtained with an integrating sphere and tungsten light bulb. We describe the calibration method and results in this study.