• 제목/요약/키워드: Flashover rate

검색결과 44건 처리시간 0.024초

건축물 화재시 개구분출화염으로 인한 상층부로의 화재확대 위험성평가 방법 구축 (Establishment of the Method for Evaluating the Risk of Fire Spread to the Upper Floors due to Ejected Flame from an Opening in the Building Fires)

  • 신이철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.216-217
    • /
    • 2020
  • As the fire inside the building grows rapidly, ejected flame from an opening occurs due to flashover. As a result, the number of cases where the flame spreads to the exterior of the building and rapidly expands to the upper floor is increasing. In particular, in the case of the fire in the Daebong Green Apartment, Uijeongbu in 2015, it was a case where the flame spread to adjacent buildings due to the opening eruption flame from the first ignited building, causing great damage to three apartments. Therefore, this study is to introduce an international standard under development that estimates the shape and properties of the ejected flame from an opening and quantitatively evaluates the radiant heat flux received by the exterior wall of the building by assuming the occurrence of the ejected flame from an opening.

  • PDF

뇌사고율 저감을 위한 154 kV 송전선의 차등절연 적용 방안 연구 (A study on the Unbalanced Insulation of the Double Circuit 154 kV Transmission Lines to Reduce Lightning Failure Rate)

  • 곽주식;강연욱;우정욱;심응보;김우겸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.151-159
    • /
    • 2003
  • According to the records, approximately 50 percent of power failure were caused by lightning. Conventional fault preventive measures against lightning include reduction of the footing resistance of the tower, multiplication of overhead ground wires and unbalanced insulation of the double circuit transmission tower. In addition to these, transmission line arresters have been recently appeared as an alternatives. In this paper an unbalanced insulation method with transmission line arrester was assumed as another countermeasure against simultaneous double circuit trip of 154 kV transmission line by lightning strike. The lightning performance of line arrester was compared with conventional insulation concept using different numbers of porcelain and glass insulator. Larger numbers of insulator simply increase flashover current level by lightning but the lightning performance doesn't proportional to it. EMTP simulation and predictive calculation of lightning failure rate were carried out to evaluate the performance.

  • PDF

안전기준을 만족하는 철도차량 내장재의 화재 열방출율 측정시험 (A Fire Test Measuring the Heat Release Rate of Railway Car Interior Materials Satisfying the Korean Safety Guideline)

  • 박원희;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.40-49
    • /
    • 2009
  • 철도차량 내장재를 설치한 화재 시험 공간(ISO 9705)에서 대규모 화재시험이 수행되었다. 여기서 사용된 내장재는 2004년 12월에 공포된 철도차량에 대한 안전기준을 만족하는 내장재이다. 화원으로는 가스버너를 이용하였으며 가스버너의 출력은 시간에 따라 증가하도록 설정하였다. 본 시험의 목적은 철도차량 내장재의 화염전파와 발화에 대한 화재 성능 평가이며, 플레시오버로 성장하는 철도차량 내장재를 포함하는 화재에 대한 여러 데이터들의 확보이다. 이 데이터들은 철도차량 내장재의 화재 성장을 예측하는 모델을 검증하고 개발하는데 사용될 것이다.

가연성 액체의 인화점과 화재특성치와의 관계 (The Relationship between Flash Point and Fire Properties of Flammable Liquids)

  • 송영호;하동명
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.10-14
    • /
    • 2007
  • 인화점은 가연성 액체의 화재 위험성을 평가하기 위해 사용되는 중요한 특성치 중의 하나이다. 가연성 액체의 상대적인 화재 위험성을 나타낼 수 있는 특성치로서는 열방출속도(HRR), 최대열방출속도(PHRR), 발화지연시간(TTI),질량 감소율, CO및 $CO_2$발생량 등이 있다. 본 연구에서는 가연성 액체의 가연성 액체의 인화점과 화재 특성치와의 관계에 대해서 검토하였다. 이를 위하여 질량 감소율과 TTI를 측정하여 화재 특성치를 계산하였다. 그 결과, 가연성 액체의 인화점과 TTI와 관련된 화재 특성치가 상관성이 매우 높은 것으로 나타났다. 이 결과로부터 가연성 액체 화재의 상대적인 위험성을 평가할 수 있는 파라미터로 사용할 수 있었다.

  • PDF

ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험 (Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room)

  • 이덕희;박원희;정우성;황정호
    • 한국철도학회논문집
    • /
    • 제13권5호
    • /
    • pp.481-487
    • /
    • 2010
  • 구형 지하철 전동차의 내장재에 대하여 ISO 9705 시험 설비를 이용하여 화재시험을 수행하였다. 시험에 사용된 점화용 버너는 CEN/TS 45545-1 규정에 따라 출력을 조정하였다. 이 내장재 화재시험의 목적은 화원의 규모에 따라서 철도차량에서의 화재거동과 화염의 전파 경로를 평가함과 동시에 객실 내장재의 화재가 플래시오버로 진행하는 경로의 화재 데이터를 제공하는 것이다. 시험으로부터 시간에 따른 위치 별 온도 값과 열류량 및 열방출률을 측정하였고 열방출률은 수정된 화염면적기반 합량법으로 계산한 결과와 비교하였다. 이 시험 결과는 CFD 화재 시뮬레이션 기법을 이용한 철도차량 화재해석의 검증 데이터로 활용될 수 있을 것이다.

LSC를 이용한 생활용품의 발열량 특성에 관한 연구 (A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter))

  • 박영주;백창선;이해평;홍이표
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

모사된 화재의 열적환경에서 열전대를 이용한 온도 측정오차에 관한 실험적 연구 (An Experimental Study on Temperature Measurement Bias using Thermocouple in Simulated Thermal Environments of Fire)

  • 한호식;윤홍석;황철홍;김성찬
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.7-13
    • /
    • 2017
  • An experimental study was conducted to identify the quantitative measurement bias for the bare-bead thermocouple (TC), which was widely used for measuring temperature in fire experiments. To this end, an apparatus could be controlled individually gas flow rate, preheating temperature and incident radiative heat flux was developed to simulate the thermal environments of fire. A relative measurement bias of bare-bead TC was evaluated with the comparison of double-shield aspirated TC. As a result, the relative measurement bias of bare-bead TC was gradually increased with the increase in radiative heat flux with constant gas temperature. The relative bias was also significantly increased with the decrease in gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the bare-bead TC had the relative bias of approximately 400% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. The present study was intend to provide fire researchers with methodologies for the reanalyses of temperature measured using bare-bead TC, radiation corrections, and validation of fire modeling.

자외선 열화에 의한 에폭시 절연재료의 표면특성과 내트래킹성 (Surface Characteristics and Tracking Resistance of Epoxy Insulating Materials against Ultraviolet)

  • 조한구;유대훈;강형경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.495-496
    • /
    • 2008
  • This paper describes the influence of Ultra-violet irradiation on time to tracking resistance of epoxy insulating materials by use of the inclined plane test. And, the influence of surface degradation was evaluated through several method such as measurement of contact angle, surface roughness, using a scanning electron microscopy. As the 1000 hours of the surface degradation with UV-CON, the flashover time decreases at different rates depending on epoxy resin and silicone rubber specimen. As the duration of the surface degradation with UV-CON is prolonged, the contact angle of epoxy resin decreases at the rate of degradation time, while that of silicone rubber was not exchanged. It is assumed that this phenomenon is related to the decrease in hydrophobicity of the surface of the materials. Also, as to epoxy resin, the decrease of hydrophobicity due to surface degradation with UV-CON is greater than that resulting from surface degradation with WOM. The UV radiation produced chalking and crazing on the surface of the insulating materials specimen.

  • PDF

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

다양한 형상의 밀폐된 구획에서 최대 열발생률 예측을 위한 상관식 검토 (A Correlation Study for the Prediction of the Maximum Heat Release Rate in Closed-Compartments of Various Configurations)

  • 윤홍석;황철홍
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.16-23
    • /
    • 2018
  • 다양한 밀폐 구획을 대상으로 내부 체적 및 화재성장률의 변화에 따라 최대 열발생률의 예측이 가능한 상관식이 수치적으로 검토되었다. 구획의 체적은 ISO 9705 화재실의 바닥면 형상을 기준으로 길이 비의 변화를 통해 조절되었으며, 이때 천장 높이는 2.4 m로 고정되었다. 주요 결론으로서, 천장 높이의 변화가 고려된 선행연구 결과와의 비교를 통해, 천장 높이의 변화가 최대 열발생률에 미치는 영향이 검토되었다. 또한 밀폐된 구획에서 천장 높이 변화와 관계없이 최대 열발생률을 예측할 수 있는 보다 일반화된 상관식이 제안되었다. 이 상관식은 수치결과와 비교할 때 다양한 화재성장률에 대하여 평균적으로 7%, 그리고 최대 19%의 오차를 갖는 것으로 확인되었다. 마지막으로 국내 성능위주설계에 적용된 5개의 대표적인 구획을 대상으로, 제안된 상관식의 적용 가능성이 검토되었다. 본 연구결과는 화재시뮬레이션에서 요구되는 입력정보 뿐만 아니라, 밀폐된 공간에서 플래시오버에 의해 야기될 수 있는 최대 열발생률의 예측에 관한 유용한 정보를 제공할 것으로 기대된다.