• Title/Summary/Keyword: Flap failure

Search Result 156, Processing Time 0.028 seconds

Surgical endodontic management of infected lateral canals of maxillary incisors

  • Jang, Ji-Hyun;Lee, Jung-Min;Yi, Jin-Kyu;Choi, Sung-Baik;Park, Sang-Hyuk
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • This case report presents surgical endodontic management outcomes of maxillary incisors that were infected via the lateral canals. Two cases are presented in which endodontically-treated maxillary central incisors had sustained lateral canal infections. A surgical endodontic treatment was performed on both teeth. Flap elevation revealed vertical bone destruction along the root surface and infected lateral canals, and microscopy revealed that the lateral canals were the origin of the lesions. After the infected lateral canals were surgically managed, both teeth were asymptomatic and labial fistulas were resolved. There were no clinical or radiographic signs of surgical endodontic management failure at follow-up visits. This case report highlights the clinical significance and surgical endodontic management of infected lateral canal of maxillary incisor. It is important to be aware of root canal anatomy variability in maxillary incisors. Maxillary central incisors infected via the lateral canal can be successfully managed by surgical endodontic treatment.

Retrospective case series analysis of vestibuloplasty with free gingival graft and titanium mesh around dental implant

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.417-421
    • /
    • 2020
  • Objectives: The purpose of this paper is to introduce an effective technique to easily obtain adequate amounts of keratinized gingiva and vestibular depth. Materials and Methods: Free gingiva (vertical height 10 mm) was harvested on the palatal mucosa and a partial thickness flap was elevated on the recipient site with same width as the free gingiva graft. After a conventional suture, a titanium mesh covered the graft and was fixed with miniscrews. Titanium mesh was removed 4.1±2.5 weeks after surgery. The amount of keratinized gingiva and vestibular depth was measured at the final follow-up. Results: Nine patients (males 4, females 5; 53.9±14.1 years) who underwent bone graft surgery before vestibuloplasty were included. No free gingival graft failure or complications were encountered in any of the patients. The relapse rate for vestibular depth (23.3%) was lower than that for keratinized gingiva (48.3%) after 34.4±14.4 months (P=0.010). Conclusion: Vestibuloplasty with a free gingival graft using titanium mesh could be achieved with an acceptable amount of keratinized gingiva and an appropriate vestibular depth around dental implant.

HeartMate 3 Implantation via Only Left Thoracotomy: A Case Report

  • Mi Young Jang;Jun Ho Lee;Su Ryeun Chung;Kiick Sung;Wook Sung Kim;Yang Hyun Cho
    • Journal of Chest Surgery
    • /
    • v.56 no.3
    • /
    • pp.224-227
    • /
    • 2023
  • Median sternotomy is a standard surgical technique used for left ventricular assist device (LVAD) implantation. However, if sternotomy has a prohibitive surgical risk, LVAD implantation can be performed through only left thoracotomy. We managed a patient with end-stage heart failure who had recently undergone coronary artery bypass grafting (CABG) elsewhere. The patient also had a deep sternal wound infection and bacteremia. Because of refractory cardiogenic shock, we performed extracorporeal membrane oxygenation (ECMO). After multiple mediastinal washouts and omental flap placement, ECMO was converted to extracorporeal LVAD (from the left ventricular apex to the descending aorta) through a left thoracotomy. The extracorporeal LVAD was maintained for 18 days and replaced by the HeartMate 3 LVAD. The patient was discharged in good condition 115 days after CABG.

Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door (굴뚝효과와 외부출입문 개방을 고려한 부속실 제연)

  • Yongkwang Kim;Zudal Son;Seoyoung Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

Results of Extracardiac Pericardial-flap Lateral Tunnel Fontan Operation (자가심낭막절편을 이용한 심외외측통로 Fontan 수술의 결과)

  • Park Han-Ki;Youn Young-Nam;Yang Hong-Seok;Yoo Byoung-Won;Choi Jae-Young;Park Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.281-288
    • /
    • 2006
  • Background: Extracardiac pericardial-flap lateral tunnel Fontan operation has theoretical advantage of growth potentiality of the extracardiac tunnels. The mid-term results of this technique and morphologic change of the lateral tunnel were studied. Material and Method: Clinical data was reviewed in 42 patients who underwent extracardiac pericardial-flap lateral tunnel Fontan operation between November 1993 and December 2004. The age was $2.8{\pm}1.5$ years and the body weight was $12.3{\pm}3.2$ kg. Extracardiac tunnel was constructed using the pedicled pericardium with the base undetached. By reviewing the follow-up cardiac angiograms, the diameter and the cross-sectional area of the lateral tunnel was compared to those of inferior vena cava. Result: There were four operative mortality cases (9.8%) and the causes of death were low cardiac output for all four cases. Postoperatively, five patients had prolonged pleural effusion longer than two weeks and one patient required a permanent pacemaker due to complete heart block. Follow-up was possible in 37 patients and the follow up duration was $3.8{\pm}2.2$ years. During that period, one patient died, of upper gastrointestional bleeding combined with heart failure and one patient died a sudden death of unknown cause. Two patients required reoperation due to subaortic stenosis and anastomosis site stenosis between inferior vena cava and lateral tunnel. In one patient, bradyarrhythmia was anew but there was no thromboembolic complication. The lateral tunnel showed growth in proportion to the size of the inferior vena cava. Conclusion: Extracardiac pericardial-flap lateral tunnel Fontan operation is relatively simple and safe. The mid-term result was favorable and the extracardiac tunnel showed potential for growth.

Treatment of Intraoperative Thrombosis and Spasm in Free Tissue Transfers Using the Fogarty Catheter (포가티 카테터를 이용한 유리조직 전이술 시 수술 중 혈전 및 연축의 치료)

  • Lee, Seung Ryul;Yun, Young Mook;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.159-164
    • /
    • 2008
  • Purpose: Microvascular free tissue transfer has become a reliable technique for the reconstruction of complex wounds. Occasionally, unexpected intraoperative thrombosis and/or spasm of recipient artery might be annoying problems even for the technically competent microvascular surgeons. If such problems are not treated properly, they will inevitably cause to flap failure. Methods: From January 2006 to February 2007, soft tissue reconstructions by free tissue transfers were performed on 21 patients having complex defects in the lower extremity. Although segmental revision and various pharmacologic agents were repeatedly applied, arterial occlusions were not managed in 6 cases. For removal of thrombi and release of spasm, Fogarty No. 2 or No. 3 catheters were inserted into the lumen to the proximal recipient artery. Its balloon was then inflated after passing through a resistant area. Next, the catheter was gently withdrawn backward. Results: After the Fogarty catheter was inserted two or three times, the pulsatile arterial flow was restored. When the catheter was inserted into the lumen, a feeling of resistance existed in a 5-10cm more proximal portion that could not be easily accessed from the vascular end. After the reestablishment of blood flow, successful anastomoses were achieved and immediate rethrombosis or spasm did not occur. No long-term sequelae associated with balloon trauma to the arterial wall were observed. Conclusion: The use of the Fogarty catheter can be an effective method in treating pedicle thrombosis and spasm. This is a very simple and rapid technique that offers microvascular surgeons another option to increase the success rate of microvascular anastomosis in free tissue transfers.

Prevention of Implant Malposition in Inframammary Augmentation Mammaplasty

  • Kim, Yoon Ji;Kim, Yang Woo;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.407-413
    • /
    • 2014
  • Background Implant malposition can produce unsatisfactory aesthetic results after breast augmentation. The goal of this article is to identify aspects of the preoperative surgical planning and intraoperative flap fixation that can prevent implant malposition. Methods This study examined 36 patients who underwent primary dual plane breast augmentation through an inframammary incision between September 1, 2012 and January 31, 2013. Before the surgery, preoperative evaluation and design using the Randquist formula were performed. Each patient was evaluated retrospectively for nipple position relative to the breast implant and breast contour, using standardized preoperative and postoperative photographs. The average follow-up period was 10 months. Results Seven of 72 breasts were identified as having implant malposition. These malpositions were divided into two groups. In relation to the new breast mound, six breasts had an inferiorly positioned and one breast had a superiorly positioned nipple-areolar complex. Two of these seven breasts were accompanied with an unsatisfactory breast contour. Conclusions We identified two main causes of implant malposition after inframammary augmentation mammaplasty. One cause was an incorrect preoperatively designed nipple to inframammary fold (N-IMF) distance. The breast skin and parenchyma quality, such as an extremely tight envelope, should be considered. If an extremely tight envelope is found, the preoperatively designed new N-IMF distance should be increased. The other main cause of malposition is failure of the fascial suture from Scarpa's fascia to the perichondrium through an inframammary incision. As well, when this fixation is performed, it should be performed directly downward to the perichondrium, rather than slanted in a cranial or caudal direction.

Secondary Breast Reconstruction (이차 유방 재건술)

  • Ahn, Hee Chang;Ahn, Yong Su;Kim, Youn Hwan;Choi, Seung Suk
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.761-766
    • /
    • 2009
  • Purpose: Secondary breast reconstruction is defined as a whole reconstructive procedure to correct complications and to improve the aesthetics when a patient is dissatisfied with her initial reconstruction. We would like to present these particular procedures on previously failed breast reconstruction with analysis of unsatisfactory results. Methods: From June 2002 to August 2008, we performed secondary breast reconstructions for 10 patients with failed breasts. Six patients with implant failure underwent secondary breast reconstructions using free TRAM flaps after the removal of implants. Two patients with partial loss of pedicled TRAM flaps underwent secondary breast reconstruction using Latissimus Dorsi flaps. Two patients with 1 total loss of free TRAM flap and 1 extensive fat necrosis underwent secondary breast reconstruction using implants. Results: The average age of the patients were 36.4 years (26 ~ 47 years). All flaps survived completely and had relatively good aesthetic results in free TRAM cases. There was breast asymmetry in one patient using cohesive gell implants in total loss of previously free TRAM patient, which was corrected by exchanging the implants and placing dermofat grafts. Conclusion: Secondary breast reconstruction differs from primary procedures in several aspects; there are changes in the anatomy and tissue environment of the breasts, and various limitations in choosing reconstruction methods. In addition, the patients may be uncomfortable with previous complication. It is important to consider various factors before deciding to undergo a secondary breast reconstruction carefully with informed consent.

The Surgical Impact of E-Cigarettes: A Case Report and Review of the Current Literature

  • Fracol, Megan;Dorfman, Robert;Janes, Lindsay;Kulkarni, Swati;Bethke, Kevin;Hansen, Nora;Kim, John
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.477-481
    • /
    • 2017
  • We report a case of a 51 years old female with a 25 pack year smoking history who underwent bilateral mastectomy and immediate tissue expander reconstruction for newly diagnosed right breast cancer. The patient reported herself as a non-smoker despite significant e-cigarette use, with resulting significant mastectomy skin flap necrosis and breast reconstruction failure. Little is known about the physiologic effect of e-cigarettes on wound healing and tissue perfusion. To this end, we provide an updated review of the impact of e-cigarettes on surgical outcomes. PubMed, Ovid MEDLINE, and PRS GO were searched for the terms "e-cigarette", "electronic cigarette", "e-cig", "electronic nicotine delivery system", "vaping", "surgery", "surgical", "peri-operative", "operate", "operative", and "wound healing". Abstract review of all articles was performed. 123 articles returned that contained both variants of e-cigarettes and surgery as keywords. Of those, manual assessment returned three articles which were found to be relevant to e-cigarette use in the surgical patient. No articles were found that compared perioperative complications in e-cigarette versus traditional cigarette users in humans. In conclusion, our case report depicts the potential dangers associated with e-cigarette use in the surgical patient. There is a public misconception that e-cigarettes are healthier than traditional cigarettes and as such their use may go unreported by patients. Early evidence suggests e-cigarettes may induce some of the same physiologic changes as traditional cigarettes, and may have a significant deleterious effect on wound healing.

Repair of Coarctation (including tubular hypoplasia) in Infancy and Children (영아 및 소아 연령에서의 대동맥 교약증의 교정 수술)

  • 한재진
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.474-481
    • /
    • 1990
  • We have experienced 44 cases of coarctation of aorta in the age of infancy and children from April 1986 to September 1989 at Seoul National University Children`s hospital. Patients were thirty males and fourteen females, and their age ranged from one month to ten years[mean 23.84 $\pm$33.06 months] with thirty-two infant cases. In the infantile age, congestive heart failure was the most common chief complaint[18/32], and above that age, frequent upper respiratory infection was most common[8/12]. We experienced thirteen cases of isolated COA, twenty-two cases of COA with VSD, eight cases of COA with VSD, eight cases of COA with intracardiac complex anomalies and one case of COA with atrial septal defect. The associated intracardiac complex anomalies were three Taussig-Bing type double outlet right ventricle, one single ventricle, one transposition of great arteries, one atrioventricular septal defect, one hypoplastic aortic arch with left heart hypoplasia, and one Tetralogy of Fallot. Operative techniques of COA were twenty-three subclavian flap arterioplasty, 12 resection and end to end anastomosis, eight onlay patch angioplasty, and I direct angioplasty after resection of web. Among the cases with other cardiac anomalies, staged operation was done in twenty-nine patients, and single stage total correction was performed only in three patients. There were seven operative mortality[15.9%], all being in infantile age group, and among fourteen cases associated with large VSD[Qp/Qs>2.0, mean pulmonary arterial pressure>50mmHg], four patients were died, but there was no mortality in patients with small VSD. With above results, we are intended to discuss about the interval between staged operation, the fate of VSD after coarctoplasty in case of COA with VSD, causes of death, complications etc.

  • PDF