A Study on Determination of Range of Hazardous Area Caused by the Secondary Grade of Release of Vapor Substances Considering Material Characteristic and Operating Condition (물질특성 및 운전조건을 고려한 증기상 물질의 2차 누출에 따른 폭발위험장소 범위 선정에 관한 연구)

  • Seo, Minsu;Kim, Kisug;Hwang, Yongwoo;Chon, Youngwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.13-26
    • /
    • 2018
  • Currently, local regulations, such as KS Code, do not clearly specify how to calculate the range of hazardous area, so the dispersion modeling program should be used to select dispersion. The purpose of this study is to present a methodology of determining the range of hazardous area which is simpler and more reasonable than modelling by using representative materials and process conditions. Based on domestic and overseas regulations that are currently in effect, variables affecting distance to LFL(Lower Flammable Limit) were selected. A total of 16 flammable substances were modelled for substance variables, process conditions variables, and weather conditions variables, and the statistical analysis selected the variables that affect them. Using the selected variables, a three-step classification method was prepared to select the range of locations subject to explosion hazard.

A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids (인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구)

  • Gyu Sun Cho;Sang Ryung Kim;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • Although Korea is the world's No. 1 semiconductor producing country, most studies are conducted with risk assessment for simple material risks due to the closedness of the site for industrial protection. In terms of industrial safety, a monitoring system such as a gas detector to determine the leakage of hazardous substances has been established, but research on effectively discharging harmful gastritis substances in case of leakage has only recently begun. Semiconductor manufacturing facilities (gas boxes) where a large amount of flammable materials are handled are currently being safety managed by using a gas detector and blocking the air inlet. It is difficult to dilute in a short time in case of leakage of flammable substances. Therefore, in this study, based on various criteria, the size of the duct according to the size of the gas box is determined and the appropriate size of the air inlet is studied to minimize the exhaust performance requirement without exposing hazardous chemicals to the outside in the event of a flammable leak. We want to do an optimal exhaust design.

A Study on the Origination of Backcountry Litter in Moaksan Provincial Park (모악산도립공원의 산쓰레기 발생특성)

  • Rho, Jae-Hyun;Huh, Joon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.5
    • /
    • pp.64-72
    • /
    • 2007
  • This study investigated the types, forms, and origination of litter found along one hiking course in Moaksan Provincial Park, 'Jungin-ri Course'(entrance-ridge-valley-peak). In addition, a survey was conducted to understand hikers' litter control awareness in order to determine possible backcountry litter control measures. The following are the results of this study: 1. For the litter Sequency investigation, 199 recyclable pieces of litter were found on the mid-slope(61.6%), 89 by the entrance(27.6%), 19 in the valley(5.9%) and 16 on the peak(4.9%). A total of 323 pieces of litter were found. Paper materials were the most common, followed by plastic containers such as PET bottles and yogurt containers. Of particular interest, 288 papers and cans were found on the mid-slope(46.9%). By the entrance, more plastics and bottles were found. 2. There were 614 pieces of flammable litter collected and only 19 pieces of non-flammable. Most of the flammable litter, including snack pacts, plastic bags, processed lumber, cigarette butts, tissues, cigarette boxes, and fabric was found on the mid-slope. 3. Very little food waste was found throughout the whole site proving that the policy prohibiting hikers from cooking and eating at the designated sites has been effective. However, food waste is difficult to find because it naturally decays with time. 4. $X^2$-test was used to find different types of litter and their verified origination frequency. It was found that recyclable litter, and food waste took about 1%. In addition, recyclable litter, especially bottles, was found relatively frequently by the entrance. Flammable litter was found most often at the peak. 5. The questionnaire results showed that 48.2% of the respondents "shorten their hiking journey and purchase food outside the entrance" and 29.6% said that they "bring a packed meal from home". Only 8.2% said that they "cook something when an appropriate location is found". At the Jungin-ri course, a few hikers brought their own food to eat or cook, but most hikers purchased something to eat onsite. 6. The results of the question about having experience littering while hiking showed that 19.3% litter and 79.2% do not. Those that responded "yes" gave various reasons for littering. 63.6% claimed, "there are no designated trash containers". 15.9% said they litter subconsciously. Finally, 3.2% insist that they litter "because food naturally decomposes". 7. As a result of the overall satisfaction according to the Likert scale and the analysis with an average of 14 variables, it was found that the average "toxic litter control convenience" was 2.41 with very low satisfaction. Thus, the results indicate the importance of providing appropriate back country litter control facilities.

A Study on the Review of Repair Methods and Repair Materials for the Prevention of Fire spread of Building Exterior Materials (건축물 외장재의 화재확대방지를 위한 보수구법 및 보수재료 검토에 관한 연구)

  • Lee, Byeong-Heun;Jin, Seung-Hyeon;Park, Sung-Ha;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.105-111
    • /
    • 2019
  • In Korea, the results of a field survey on the construction of flammable exterior materials implemented in 2018 revealed that 147,559 buildings belong to this category. It was found that the fire spreading cases in upper and adjacent constructions are about 3,500 per year, the fires of starting in flammable exterior material are about 1,500 per year. In this study, we investigated the repair method of buildings constructed by flammable exterior material and conducted performance verification of each repair materials for prevention of similar fire. In the case of the repair method, a method of reinforcing with a repair material after removing the existing building finishing material and a method of attaching the repair material after performing the face finishing are proposed. In addition, we conducted cone calorimeter tests of 6 materials such as fireproof gypsum board, mineral wool, hard urethane foam, ceramic board and ALC panel as dryvit and repairing materials, and investigated basic combustion performance of that materials.

A Study on the Ignition Hazards of Flammable Mixtures by Radio Frequency Radiation (고주파 방사에 의한 가연성가스의 점화 위험성 고찰)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1749-1751
    • /
    • 1998
  • Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.

  • PDF

A Study on Estimation of Lower Explosive Limits of Alcohol Compounds (알코올화합물의 폭발하한계 추산에 관한 연구)

  • Dong-Myeong Ha;Yong-Chan Choi;Haejin Oh;Su-kyung Lee
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.291-296
    • /
    • 2002
  • Flammable compounds are indispensible in domestic as well as in industrial fields as fuel, solvent and raw materials. The fire and explosion properties necessary for safe storage, transport, process design and operation of handling flammable substances are lower explosive limits(LEL), upper explosive limits(UEL), flash point, fire point, AIT(auto ignition temperature), MIE(minimum ignition energy), MOC(minimum oxygen concentration) and heats of combustion.

  • PDF

Trial Construction for the Prevention of Fire Spread in Piloti Building (필로티건축물의 화재확산방지를 위한 시범시공)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

A Study on the Fire Risk Assesment of Solvent-based Paints (유성페인트의 화재 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Kwon, Seong-Pil
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • Currently, flammable liquids account for more than 87 wt% of the hazardous materials in circulation in Korea, and paint products are the most commonly used mixed hazardous materials. Therefore, one of the most urgent and important issues is that we have to secure the safety for manufacturing, storage and transport of paint products. In this study we investigated and analyzed the domestic hazardous materials safety management method, the international GHS test method and so forth. We tested risks for a variety of oil paints and found a relation between the results. Furthermore, the risk test method and criteria adapted for domestic situation was presented. Paints were classified as hazardous or non-hazardous according to the results of the flash point test, the amount of flammable liquid or the UN-combustion persistence test. It was revealed from the test results of 6 kind of oil-based paints using different resins that they were hazardous materials with very high risks and belonged to the Category 1 or the Category 2.

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.