• 제목/요약/키워드: Flammability test

검색결과 66건 처리시간 0.022초

원자력발전소 케이블 난연성능 검증 방법론 개선을 위한 연구 (A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants)

  • 이상규;문영섭;유성연
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.140-144
    • /
    • 2017
  • Fire protection for nuclear power plants should be designed according to the concept of "Defense in Depth" to achieve the reactor safety shutdown. This concept focuses on fire prevention, fire suppression and safe shutdown. Fire prevention is the first line of "Defense in Depth" and the licensee should establish administrative measures to minimize the potential for fire to occur. Administrative measures should include procedures to control handling and use of combustibles. Electrical cables is the major contributor of fire loads in nuclear power plants, therefore electrical cables should be fire retardant. Electrical cables installed in nuclear power plants should pass the flame test in IEEE-383 standard in accordance with NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants". To assure the fire retardant of electrical cables during design life, both aged and unaged cable specimens should be tested in accordance with IEEE-383. It can be generally thought that the flammability of electrical cables has been increased by wearing as time passed, however the results from fire retardant tests performed in U.S.A and Korea indicate the inconsistent tendency of aging and consequential decrease in flammability. In this study, it is expected that the effective methodology for validation of fire retardant performance would be identified through the review of the results from fire retardant tests.

Melamine계 난연제를 이용한 Nylon6의 난연성 및 물리적 특성 평가 (Evaluation of mechanical properties and non-flammability of Nylon6 using melamine-based halogen-free flame retardant)

  • 김동학;류관석;손영곤
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.743-748
    • /
    • 2006
  • 본 논문에서는 연구에서는 Nylon6를 기재로 하여 두 가지 Melamine계 난연제(melamine cyanurate: MC-100 and melamine phosphate:MPP-100)를 사용한 난연 Nylon를 개발하여 난연성 및 물성평가를 수행하였다. 난연Test는 UL-94 측정방법(수직연소 시험방법)을 이용하였고, 물성평가는 만능물성시험기(UTM)를 이용하여 인장강도, 굴곡강도, 굴곡탄성율 등을 측정하였고, 충격강도 시험기를 이용하여 충격강도를 측정하였다. 또한 Nano-clay(Cloisite 30B) 5wt%를 사용하여 물성에 미치는 효과를 관찰하였다. 수지의 난연성 평가결과에 의하면, 난연제의 함량이 5wt% 이상이면 V0급을 얻을 수 있었다. 난연제 함량이 증가함에 따라 인장강도. 굴곡강도는 감소하고, 굴곡탄성율은 증가하였다. MC-100의 경우, 5wt%까지는 Nylon6의 동등 이상의 물성을 유지하였다. Nano-clay의 경우, 분산 상태가 불량하여 기대 수준의 물성 향상과 난연 효과는 얻지 못했다.

  • PDF

인계 난연 단량체와의 공중합을 통한 난연성 수성 아크릴 에멀젼 점착제 제조 (Synthesis of flame retardant acrylic emulsion pressure sensitive adhesives by co-polymerization with phosphoric flame retardant monomer)

  • 전민석;정지훈;김구니
    • 접착 및 계면
    • /
    • 제20권4호
    • /
    • pp.135-139
    • /
    • 2019
  • 본 연구에서는 인계 난연성 단량체를 점착성 아크릴 단량체인 butyl acrylate, 2-ethylhexyl acrylate, methyl methacrylate, acrylic acid, 2-hydroxyethyl methacrylate와 고형분 65%에서 공중합을 진행하여 난연성 수성 아크릴 에멀젼 점착제를 합성하였다. 이때 전환율은 100%를 보이며 인계 난연 단량체의 첨가량에 따라 점착제의 점도에 차이가 발생하였고 최대 5500cps의 점도를 나타내었다. FT-IR로 아크릴 점착제의 구조분석을 진행하였고, differential scanning calorimeter (DSC) 열적 특성을 측정하였다. 인계 난연 단량체의 첨가에 따라 유리전이온도(Tg)는 미첨가시 -44.1℃에서 최대첨가량 15part에서 -31.4℃로 증가하였다. 박리강도는 미첨가시 2100gf/inch였으며 첨가량 15part에서는 200gf/inch를 나타내었고 난연성 수성 아크릴 에멀젼 점착제의 방염성을 평가하여 난연성 점착제로서의 특성 확인하였다.

산소지수법(酸素指數法)에 의(依)한 목질판상재료(木質板狀材料)의 연소시험(燃燒試驗) (Oxygen Index Evaluation of Wood-Based Materials)

  • 이필우;정인주
    • 한국산림과학회지
    • /
    • 제78권4호
    • /
    • pp.396-400
    • /
    • 1989
  • 본(本) 시험(試驗)은 산소지수법(酸素指數法)에 사용(使用)하여 목질판상재료(木質板狀材料)의 상대적(相對的) 연소성(燃燒性)과 그들의 산소지수(酸素指數)를 알아보기 위하여 수행(遂行)되었다. 산소지수(酸素指數)는 일정비율(一定比率) 산소(酸素), 질소(窒素) 혼합기체(混合氣體)의 흐름속에서 재료(材料)가 발염연소(發炎燃燒)를 지속(持續)할 수 있는 최소(最少) 산소농도(酸素濃度)를 말한다. 본(本) 시험(試驗)에서는 산소지수(酸素指數)를 계산(計算)하기 위하여 Dixon과 Massey의 Up and Down법(法)을 사용(使用)하였으며 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 산소지수(酸素指數)는 합판(合板)이 27.9%로 가장 높게 나타났으며, MDF와 파티클보드의 산소지수(酸素指數)는 각각 26.9%와 26.2%이었다. 이것은 합판(合板)이 MDF나 파티클보드에 비해 난연소성(難燃燒性)을 가지고 있는 것을 나타낸다. 2. 산소지수(酸素指數)는 혼합기체유동속도(混合氣體流動速度)에 의하여 영향(影響)을 받지 않았다.

  • PDF

폐목재 칩을 활용한 목질계 보도포장재의 특성에 대한 기초연구 (Basic Study on the Characteristics of Wooden Sidewalk Pavement Material using Wood Waste Chip)

  • 최재진;송진우
    • 대한토목학회논문집
    • /
    • 제31권3D호
    • /
    • pp.413-420
    • /
    • 2011
  • 건설현장에서 나오는 폐목재 또는 활용가치가 낮은 벌목지에서 발생하는 나무뿌리와 가지 등의 임목폐기물을 분쇄한 목재 칩을 우레탄 수지로 결합시킨 보도용 포장재를 제안하기 위한 실험을 실시하였다. 시험체는 재료혼합비율로서 건설폐목재 칩 및 임목폐기물 칩에 대한 우레탄 수지의 질량비를 0.5, 0.75, 1.0의 3수준으로 정하고 재료 계량 후 믹서로 혼합, 성형한 다음 7일이 경과하였을 때 인장강도 시험, 골프공과 스틸볼을 이용한 탄력성 시험, 투수계수 측정 및 가연성 시험을 실시하였다. 실험결과 공기중 건조상태에서 시험체의 인장강도는 0.2~1.1MPa의 범위를 나타냈으며 재령 7일 이후의 강도 변화는 나타나지 않았다. 그러나 침수시켰을 때 강도가 저하되었으며 그 강도의 저하비율은 우레탄 수지의 사용량이 적을수록 크게 되므로 강우 등에 의한 수분 침투를 고려하여 폐목재 칩에 대한 수지의 질량비는 0.75 이상으로 하는 것이 바람직하다고 판단된다. 탄력성 시험결과로서 폐목재 칩과 우레탄 수지를 사용한 시험체의 GB계수와 SB계수는 20% 이하의 낮은 값으로 측정되어 보도용 포장재로서 우수한 특성을 나타냈다. 또한 투수계수는 모든 배합의 시험체에서 0.5mm/sec 이상으로, 투수성 포장재에 있어서 시공 후 요구되는 일반적인 투수계수의 기준값을 상회하였으며, 목질계 포장재의 가연성은 실용상 특별히 문제가 되지는 않을 것으로 판단되었다.

보강성 충진제를 첨가한 실리콘 고무의 난연 및 화재안전 특성에 관한 연구 (A Study on the Properties of Flame Retardant and Fire Safety of Silicone Rubbers Added Reinforcing Fillers)

  • 박승호;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.349-355
    • /
    • 2019
  • A fire, be it caused intentionally or unintentionally, leads to economic loss and physical damage, and requires digestion. The number of fires is increasing yearly, and electrical fires account for more than 30% among the main causes of fires. Electric wires that catch fire typically employ silicone coatings; silicone has organic as well as inorganic properties. Silicon is a natural, nonexistent, synthetic product with numerous applications. In this study, a silicon rubber for application in wires was prepared by high-temperature vulcanization (HTV) with a Shore A hardness of 70. We report results for the flame retardancy test and the fire safety characteristics via inorganic analysis. For this, a quartz inorganic material was added to the wire specimen, and 18% powdered extinguishing agent ammonium phosphate and expanded vermiculite respectively. Thus, expanded vermiculite showed the best flame retardancy and fire safety characteristics.

화학물질의 위험성평가에 관한 연구 (A Study on the Assessment of Hazardous Properties of the Chemicals)

  • 이봉우;박철우;송학;최정수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.262-269
    • /
    • 2008
  • Chemical products have had an favorable influence on our everyday life, and contributed very much to the development of human culture. According to the rapid change of industry and the development of scientific technique the using chemical products are increasing more and more. Chemical products can have any hazardous property such as flammability or explosiveness. There are occurring many accidents in the international trade due to the different classification and labelling of chemicals produced in various countries. The main purpose of this work is the development of global standard test methods for the chemicals, and the classification and labelling in building block approach by means of the basic technical data. Oxidizing solids, combustible solids, spontaneously combustible materials, water-prohibitive materials, flammable liquids, self-reactive materials and oxidizing liquids have been tested. The results have been classified according to the hazard material safety regulation and the UN regulation, and summarized in a data-base.

  • PDF

콘베어 고무벨트의 난연성(難燃性) 및 내열성(耐熱性)에 관(關)한 연구(硏究) (Studies on the Inflammability and Heat Resistance of Conveyer Rubber Belts)

  • 오평제
    • Elastomers and Composites
    • /
    • 제16권4호
    • /
    • pp.211-216
    • /
    • 1981
  • A series of conveyer rubber belts has been made by blending natural rubber(NR), styrene butadiene rubber(SBR), chloroprene rubber(CR) and additives on nylon cords, and their respective flammability has been investigated. It has been observed that: 1. By adding an antiflame agent to the belt, in addition to 70% chlorinated paraffine and antimony oxide($Sb_{2}O_{3}$), the inflammability is improved remarkably to O - 2 seconds due to the synergistic effect, while a sample without antiflame B fails to pass the KS M 6678 test. 2. Physical properties, such as tensile strength, elongation at break and adhesion strength, of the sample belts have been studies by varying ratios of NR/CR from 20 to 100, and it has been observed that the higher ratios have the better physical properties.

  • PDF

열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구 (A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps)

  • 송영재;정동수
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

전기장판의 화재위험성 실험연구 (An Experimental Study on the Fire Hazard of Electric Heating Pad)

  • 이복영;박찬호;박상태;홍성호;유현종
    • 한국화재소방학회논문지
    • /
    • 제20권3호
    • /
    • pp.113-117
    • /
    • 2006
  • 본 연구는 가정용 전열제품인 전기장판에 대한 화재실험과 난연성실험을 통하여 화재위험성을 분석하였다. 화재실험은 정상조건에서 정격전압을 인가하는 경우와 온도조절기 고장시 정격전압이 인가되는 경우를 모델링하였다. 난연성실험은 UL 94의 수직 연소시험방법을 이용하여 전기장판의 난연성능을 평가하였다. 실험에 사용된 전기장판의 종류는 전기매트, 전기요, 비닐장판이다. 실험결과 온도조절기가 고장난 상태에서 정격전압이 인가되는 경우 화재위험성이 높은 것으로 나타났으며 전기장판의 재질은 난연성이 없는 것으로 나타났다.