Assessment of material analysis for Halogen free flame retardant concentric neutral type Power cable (난연성 동심중성선 전력 케이블의 재료에 대한 평가 기술)

  • Soh, Jin-Joong;Shim, Dae-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1460-1462
    • /
    • 2002
  • The test methods on materials of electrical power cable are used in accordance with 25 specifications of IEC, ASTM, ICEA, KS and KEPCO Spec. The validation of test methods were checked and stablished by solving the problems occurred during the test. These tests are flammability, degree of acidity of gases, amount of halogen acid gas, smoke density, oxygen index, amount of ion in semiconductor, void, amber, contaminant and water tree, crosslinked density. Then the performance of power cable made by A, B, C and D company were evaluated and compared.

  • PDF

Comparison of the Heat Release Rate between the results of Cone-Calorimeter and flame spread tester (콘칼로리미터법과 화염전파 시험법의 발열량 평가 비교)

  • Lee Duck-Hee;Jung Woo-Sung;Lee Cheul Kyu;Cho Hee-Ki;Lee Dong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.935-940
    • /
    • 2005
  • We generally get the Heat Release Rate by two other method. One is the calculation method from the Oxygen consumption rate and another is the calibration curve method of Temperature rising rate. In this study we compare the results of both test methods with five same specimens. From the test result we get the difference of reproducibility and checked some reasons of the difference. This paper includes some points to be careful for more creditable results for each test method.

  • PDF

A Study on Diesel Spray Combustion Modeling by Eulerian and Lagrangian Conditional Moment Closure Models (Eulerian 및 Lagrangian CMC 모델을 사용한 디젤분무연소 모델링에 관한 연구)

  • Kim, Woo Tae;Cho, Hyun Su;Huh, Kang Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.195-198
    • /
    • 2012
  • Numerical simulation is performed to evaluate the conditional moment closure (CMC) models for spray development, ignition, and turbulent combustion for the Engine Combustion Network (ECN) test cases. The CMC model is implemented in the open source code, OpenFOAM, to provide conditional flame structures through the solution of Eulerian as well as Lagrangian conditional transport equations. In spite of more accurate treatment of the convective term, Eulerian CMC provides similar ignition delays and lift-off lengths with Lagrangian CMC.

  • PDF

A Study on the Temperature Distribution of Thermally Protected Steel column Esposed to the Fire (화재시 내화피복철골기둥의 온도분포에 관한 연구)

  • hyeon, Cheol;Kim, Moon-Han
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • This paper is concerned with the numerical analysis of the temperature of steel columns when they are exposed to flame of a fire temperature curve in order to test resistivity against the fire. In this stuer a 2-dimensional heat conduction FDM was developed to predict the temperature dustribution of steel column under various construction conditions. A proposal to estimate the influence of free water content in the insulation also made.

  • PDF

Investigation of Performent Standards for the Fire Damper (방화Damper의 성능기준 고찰)

  • Jo, Jung-Dal
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF

Fire Safety Characteristics of the FRP composites for railcar (철도차량용 FRP 내장재의 화재안전성 평가)

  • 이덕희;정우성;김용기;김선옥
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.962-968
    • /
    • 2002
  • In this study we reported the Smoke Density, the Toxicity, the Flame Spread Characteristics and the Oxygen Index of the FRP composite interior panels for raicars. Also investigated the test codes of the concerning items of other countries. We made some samples to the variance of resin types, surface finishing methods and panel shapes. It's not the really used ones but may help us effectively to guess the fire safety characteristics of railcars.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

Research for the Configuration of the Outside Sprinkler System (외벽방호 스프링클러시스템 구성에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Sun, Ju-Seok;Jeong, Sang-Ho;Chea, Chang-Hun;Kim, Suck-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.102-112
    • /
    • 2012
  • In this research, configulation of outside sprinkler system the prevention and postponement of vertical diffusion of blaze was studied prior to this study, vertical diffusion protecting sprinkler head has been developed and the sprinkler system was applied with discharge pressure of 0.05 MPa and flow of 60 l/min witch is stated in NFPA13's Exposure Protection Sprinkler Systems. Through the system design, we applied the system to the sample building and we made pertinent system to work manually and automatically linked to a fire alarm system. Also, we conducted a real-size mock up test verify the cooling effect of the outer wall and the postponement effect of the flame.

Evaluation of Combustion Instability in a Model Gas Turbine Adopting Flame Transfer Function and Dynamic Mode Decomposition (화염 전달함수 및 DMD 기법을 이용한 모형 가스터빈의 연소불안정성 평가)

  • Son, Jinwoo;Sohn, Chae Hoon;Yoon, Jisu;Yoon, Youngbin
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • To evaluate the combustion instability of a gas turbine combustor, the DMD technique was applied. The mode frequency results for each fuel composition were compared with FFT(Fast Fourier Transform) results. The damping coefficient, which is a quantitative parameter for combustion instability, was evaluated for 5 experimental cases. The flame transfer function (FTF) was calculated in the most unstable test case. In deriving the FTF, gain and phase were calculated using DMD technique. As a result of the analysis of the OH radical perturbation of the DMD, the heat release fluctuation was the highest at 100 Hz, at which the highest value of gain is observed. The frequency of FFT and FTF were different. In order to clarify the reason for this, FTF for various resonance frequencies was performed and it shows that the pattern of gain was similar to FFT.

The Effect of Intake Swirl Ratios on Combustion Performance in a Heavy-Duty LPG Engine (대형 LPG 엔진의 흡입 스월비에 따른 연소성능에 관한 연구)

  • 한병주;김창업;강건용;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.46-53
    • /
    • 2001
  • To optimize the intake flow condition in the heavy-duty LPG SI engine, five different swirl ratios of intake port were investigated experimentally by oil spot method, LDV and single cylinder engine test. The flow characteristics near the piston surface were observed by oil spot method and magnitudes of swirl flow were measured quantatively by LDV method in the steady flow rig. The engine performances of various swirl flow were also tested with the heavy-duty LPG SI single cylinder engine. In the results, high swirl ratio, above $R_s$=2.3, was not suitable to develope a stable flame kernel and to produce high engine performance. Especially it was more serious under lean burn conditions, since turbulence intensity was smaller than bulk flow though those are increased together. These results were also confirmed by LDV measurement and oil spot method. On the contrary, low swirl ratio($R_s$=1.3) is not good to propagate a flame since the turbulence intensity and bulk flow are vanished during compression stroke and low swirl ratio has too weak initial energy for stable combustion. Therefore, the of optimized swirl ratio f3r the heavy-duty LPG engine in this work was found around $R_s$=2.0.

  • PDF