• Title/Summary/Keyword: Flame Ionization Detector

Search Result 115, Processing Time 0.026 seconds

Measurement of unburned methanol and formaldehyde emissions from methanol fueled vehicles (메탄올자동차 배기배출물중의 미연메탄올 및 포름알데하이드 측정)

  • 명차리;한상순
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.89-94
    • /
    • 1991
  • In the quantitative analysis of oxygenated exhaust emissions (unburned methanol, formal- dehyde) from methanol fueled vehicles, the oxygen contained in oxygenated exhaust gases lowers the FID (Flame Ionization Detector) response factor of conventional THC analyzer and leads to erroneous HC reading. For correct measurement of various HCs including oxygenated HCs emitted from FFV(Flexible Fuel Vehicle), first of all, the measurement technique of real HC emissions should be established. GC and HPLC-DNPH measuring methods specified by the EPA are used in this paper to analyze unburned methanol and formaldehyde components in the exhaust emissions. In emission test of FFV, unburned methanol and formaldehyde are emitted mostly during cold transient period, and it is shown that formaldehyde emission level is proportional to engine displacements. In view of the HC emission level, vehicle using M85 has 40% advantage over gasoline-fueled vehicle in OMHCE and has a good potential of a low emission vehicle.

  • PDF

A Study on Engine-Out HC Emissions during Sl Engine Starting (전기점화 기관의 시동 시 미연탄화수소의 배출 특성 연구)

  • 김성수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.22-30
    • /
    • 2003
  • Engine-out HC emissions were investigated during cold and hot start. The tests were conducted according to engine cooling temperatures which were controlled by simulated coolant temperatures of cold and hot start, on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. Real time engine-out HC emissions were measured at a exhaust port and cylinder head using Fast Response Flame Ionization Detector(FRFID). Unburned hydrocarbons emitted at the cold coolant temperature were much higher than those of the hot coolant temperatures. And the main source of the high HC emission was confirmed as misfire at cold coolant temperature. In addition, the effect of intake valve timing on engine-out HC emissions was investigated. The results obtained indicate that optimized intake phasing provides the potential for start-up engine-out HC emissions reduction.

Determination of Methamphetamine and its Metabolite Amphetamine in Biological Fluids from 11 Fatal Gases

  • Yoo, Young-Chan;Chung, Hee-Sun;Choi, Hwa-Kyung
    • Archives of Pharmacal Research
    • /
    • v.16 no.3
    • /
    • pp.175-179
    • /
    • 1993
  • Gas chromoatography with flame ionization detector (FID) along with mass spectrometry (GC/MS) were used for the screening and quantification of methamphetamine (MA) and its major metabolite, amphetamine (AM0, in blood and urine in eleven fatal cases in which MA abuse was suspected. Postmortem blood MA varied from $0.5-30.2\;\mu{g/ml}$, while Am levels ranged from none detected (6 of 11 cases) to 4.8 .mu.g/ml. Additionally, distribution studies were performed in three of these cases in which tissue smaples were available for evaluation. Liver contained the highest ocncentration of MA among the tissu samples. In eight of the eleven cases, when no other direct cause of death was evident (i.e. 3 cases of traumatic dath0, either no blood AM was found or the ratio of MA/AM was 3.4 or greater. These data are consistent with acute MA use followed by death due to acute drug intoxication or by the occurrence of hypersensitivity and reverse seen in cases of chronic drug abuse.

  • PDF

The Effects of Fuel Injection Skips on the Reduction of Harmful Exhaust Gases during an SI Engine Starting (가솔린 기관의 시동시 연료분사스킵이 유해배출가스 저감에 미치는 영향)

  • Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 2006
  • During the SI engine starting up, starting conditions directly contribute to the harmful emissions in spark ignition engines. The effects of catalyst temperatures and fuel injection skip methods on HC emissions were investigated. The test was conducted on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. To understand the formation of HC emissions, HC concentration was measured in an exhaust port using a Fast Response Flame Ionization Detector(FRFID). The result showed that HC emissions, which were generated during initial stage of the starting, could be reduced by coolant temperature and fuel injection skips. And through the vehicle test of ECE15+EUDC, it is convinced that the optimized fuel injection skip method according to coolant temperatures have favourable effects on the reduction of harmful exhaust emissions including HC during the SI engine start.

  • PDF

Studies on the Analysis of Dammarane Aglycones of Korean Ginseng

  • Lee, Wang-Kyu;Kim, Byong-Kak;Kim, Hai-Jung
    • YAKHAK HOEJI
    • /
    • v.21 no.3
    • /
    • pp.163-166
    • /
    • 1977
  • To establish a convenient quantitative method for dammarane glycosides in Korea ginseng, the ginseng roots harvested at the cultivation areas of Ga Pyeong, Geum San and Jeung Pyeong were dried, powered, extracted with methanol and hydrolyzed. The ginseng root obtained at Gang Hwa was divided into three parts: main root, laterial root and cortex, and then these were treated in the same manner as the above. The various hydrolysates thus obtained were subjected to the analysis by an instrument coupled with flame ionization detector. The results showed that panaxadiol contents in the ginsengs of the three different cultivation sites were similar. However, the lateral root of Gang Hwa ginseng was found to contain the largest amount of panaxadiol among the three parts of ginseng. This method of the analysis for panaxadiol in ginseng was found to be one with relative rapidity and ease.

  • PDF

Analysis of Major Phytosterol Contents for 10 Kind of Vegetable Oils (식물성 유지 10종에 대한 주요 Phytosterol 함량 분석)

  • Cho, Sang-Hun;Lee, Myung-Jin;Kim, Ki-Yu;Park, Geon-Yeong;Kang, Suk-Ho;Um, Kyoung-Suk;Kang, Hyo-Jeong;Park, Yong-Bae;Yoon, Mi-Hye
    • The Korean Journal of Food And Nutrition
    • /
    • v.34 no.2
    • /
    • pp.217-223
    • /
    • 2021
  • Vegetable oils are a rich source of bioactive substances. Phytosterols in those have been known for many years for their properties for reducing blood cholesterol levels, as well as their other beneficial health effects. Phytosterols are triterpenes that are important structural components of plant cell membranes just as cholesterol does in animal cell membranes. The aim of this study was to provide consumers with information about phytosterol contents in vegetable oils in Korea market. The contents of major phytosterols (campesterol, stigmasterol, β-sitosterol) in 50 vegetable oils of 10 kinds (perilla oil, peanut oil, avocado oil, olive oil, pine nut oil, sesame oil, canola oil, coconut oil, grape seed oil, and sunflower oil) were analyzed by gas chromatography with flame ionization detector. The average contents of vegetable oils containing 5 or more samples were in the order of sesame oil (334.43 mg/100 g), perilla oil (262.16 mg/100 g), grape seed oil (183.71 mg/100 g), and olive oil (68.68 mg/100 g). Phytosterol content of sesame oil and perilla oil was high among vegetable oils.

Improvement of Analysis Methods for Fatty Acids in Infant Formula by Gas Chromatography Flame-Ionization Detector (GC-FID를 이용한 조제유류 중 지방산 분석법 개선 연구)

  • Hwang, Keum Hee;Choi, Won Hee;Hu, Soo Jung;Lee, Hye young;Hwang, Kyung Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • The purpose of this research is to improve analysis methods of determining the contents of fatty acids in infant formulas and follow-up formulas. A gas chromatography (GC) method was performed on a GC system coupled to flame ionization detector, with a fused silica capillary column (SP2560, 100 m×0.25 mm, 0.20 ㎛). The method was validated using standard reference material (SRM, NIST 1849a). Performance parameters for method validation such as specificity, linearity, limits of detection (LOD) and quantification (LOQ), accuracy and precision were examined. The linearity of standard solution with correlation coefficient was higher than 0.999 in the range of 0.1-5 mg/mL. The LOD and LOQ were 0.01-0.06 mg/mL and 0.03-0.2 mg/mL, respectively. The recovery using standard reference material was confirmed and the precision was found to be between 0.8% and 2.9% relative standard deviation (RSD). Optimized methods were applied in sample analysis to verify the reliability. All the tested products had acceptable contents of fatty acids compared with component specification for nutrition labeling. The result of this research will provide efficient experimental information and strengthen the management of nutrients in infant formula and follow-up formula.

Gas Chromatographic Analysis of TDI, MDI and HDI Using 2-Chlorobenzyl Alcohol and 2,4-Dichlorobenzyl Alcohol Derivatives (2-클로로벤질 알코올 및 2,4-디클로로벤질 알코올 유도체를 이용한 TDI, MDI 및 HDI의 가스크로마토그래피 분석)

  • Yun, Ju-Song;Park, Jun-Ho;Lee, Kang-Myoung;Choi, Hong-Soon;Cho, Young-Bong;Koh, Sang-Baek;Cha, Bong-Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.222-232
    • /
    • 2006
  • Objectives: The objective of this study was to propose the total isocyanate analytical method which involves derivation of 2,4-toluene diisocyanate(2,4-TDI), 2,6-toluene diisocyanate(2,6-TDI), 4,4'-methylenediphenyl diisocyanate(4,4'-MDI) and 1,6-hexamethylene diisocyanate(1,6-HDI) using 2-chlorobenzyl alcohol(2-CBA) or 2,4-dichlorobenzyl alcohol(2,4-DCBA), and analyzing of hydrolysate of the synthesized urethane with the gas chromatography(GC)/flame ionization detector(FID), GC/pulsed discharge ionization detector-electron capture detector(PD-ECD) and GC/mass selective detector(MSD). Methods: Urethanes were synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI to 2-CBA or 2,4-DCBA. Urethanes was verified by TLC, HPLC/UVD and GC/MSD. For field application, the most suitable condition that 2-CBA coated in glass fiber filter removed completely and urethanes were not removed was searched. 2-CBA generated from hydrolysis of urethanes according to hydrolysis conditions. Diisocyanates were collected on field air and analyzed. Results: Urethanes which were white and solid phase synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI, 1,6-HDI and 2-CBA or 2,4-DCBA. And urethanes were verified by TLC, HPLC/UVD and GC/MSD. The most suitable conditions to remove 2-CBA coated in glass fiber filter were $87^{\circ}C$ and 20 mmHg and urethanes were not removed under same condition. Hydrolysis yields of urethanes were 99 % to 111 %. 2-CBA, the hydrolysate of urethanes was analyzed by GC/FID, GC/PD-ECD and GC/MSD. Conclusions: Simultaneous analysis of 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI deriving with 2-CBA and 2,4-DCBA, along with a total isocyanate analysis, was feasible with GC/FID, GC/PD-ECD and GC/MSD. This result will be a guide of further study on total isocyanate analysis.

Rapid Measurement of VOC Using an Analysis of Soil-Gas (Soil-Gas의 분석을 이용한 휘발성 유기화합물 오염도 신속측정)

  • 김희경;조성용;황경엽
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.3-9
    • /
    • 1998
  • This paper presents soil-gas surveying technique to delineate an area contaminated with volatile organic compounds, which are common solvents and constituents of gasoline. The sampling method of soil-gas surveying is 1) grab sampling, which actively takes sample using a pump, or 2) passive sampling, which takes sample through diffusion in a trap filled with absorbent. The grab sampling shows the level of contamination at a certain location at a certain time, while the passive sampling shows the change in the contamination at a certain location. The analysis of soil gas can be performed with 1) a small portable detectors such as PID (photoionization detector) or FID (flame-ionization detector) to measure the total hydrocarbon in the soil gas, 2) a gas detector tube, which is filled with indicator reagents and changes its color with concentrations of the gas of interest, or 3) a portable GC (gas chromatograph), which can analyze different compounds simultaneously. The soil-gas surveying technique is a much less expensive method to investigate area contaminated volatile organic compounds and thus can be used as a screening tool to identify an area, which needs to be further investigated.

  • PDF

Headspace Analysis for Residual Hexane in Vegetable Oil

  • Oh, Chang-Hwan;Kwon, Yong-Kwan;Jang, Young-Mi;Lee, Dal-Su;Park, Jong-Sei
    • Food Science and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.456-460
    • /
    • 2005
  • To enforce the maximum residue limit for residual hexane (0.005 g/kg) in commercially available Korean vegetable oil, convenient and accurate quantification methods were investigated. Using dual surrogate standards, pentane and heptane were dissolved in ethanol, and then added to hexane-tree sunflower oil for setting up the calibration curve. Gas Chromatograph-Flame Ionization Detector with a porous layer open tubular column, indicated good chromatographic separation of hexane from other inhibiting matrix components. The lowest calibration level was $0.5\;{\mu}g/g$, not exceeding a relative standard deviation of 10% (RSD%), and 1.0\;{\mu}g/g$ not exceeding a deviation of 22% RSD% using heptane as an internal standard for the Static headspace analysis by using a headspace auto-sampler and manual injection, respectively. The residual hexane was detected in nine of the samples among 87 vegetable oil samples purchased on the local market.