A Study of the Propagation of Turbulent Premixed Flame Using the Flame Surface Density Model in a Constant Volume Combustion Chamber

  • Lee, Sangsu;Kyungwon Yun;Nakwon Sung
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.564-571
    • /
    • 2002
  • Three-dimensional numerical analysis of the turbulent premixed flame propagation in a constant volume combustion chamber is performed using the KIVA-3V code (Amsden et. al. 1997) by the flame surface density (FSD) model. A simple near-wall boundary condition is eaployed to describe the interaction between turbulent premixed flame and the wall. A mean stretch factor is introduced to include the stretch and curvature effects of turbulence. The results from the FSD model are compared with the experimental results of schlieren photos and pressure measurements. It is found that the burned mass rate and flame propagation by the FSD model are in reasonable agreement with the experimental results. The FSD combustion model proved to be effective for description of turbulent premixed flames.

A Study on the Influence of Turbulent Intensity on DOHC Engine Performance (DOHC 가솔린기관의 연소실 난류특성이 기관성능에 미치는 영향에 관한 연구)

  • Kim, C.S.;Choi, Y.D.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.2
    • /
    • pp.12-23
    • /
    • 1994
  • In order to investigate the effect of turbulent intensity on combustion characteristics, new flame factor model was developed. The principal study is the evaluation of interaction of swirl, tumble and unstrutural component of flow characteristics and correlation between turbulent intensity and flame factor. Computational and experimental study has been, performed such as quasi-dimensional cycle simulation, three dimensional flow analysis, engine performance test and diagnostic simulation. From these studies, it was found that flame factor was a function of engine speed and turbulent intensity.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

A Study on Application and Validation of the Coherent Flamelet Model in Counterflow Turbulent Premixed Combustion (대향류 예혼합 난류 연소 유동에서의 Coherent Flamelet Model 적용 및 검증에 관한 연구)

  • Choi, C.R.;Huh, K.Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.51-58
    • /
    • 1996
  • The coherent flamelet model(CFM) is applied to symmetric counterflow turbulent premixed flames. The flame source term is set proportional to the turbulence intensity to reproduce the experimental correlation of Abdel-Gayed et al. for the turbulent burning velocity. Flame quenching by the turbulent rate of strain is modeled by an additional multiplication factor to the flame source term. A modified form of CFM is employed to consider coexistence of burned and unburned premixture with ambient air. The predicted flame position and turbulent flow field coincide well with the experimental data of Kostiuk et al., although there is some discrepancy in the radial rms velocity component and integral length scale near the symmetric plane.

  • PDF

Experimental Study on the Effect of a Metal Storage Cask and Openings on Flame Temperature in a Compartment Fire

  • Bang, Kyoung-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.395-405
    • /
    • 2020
  • Compartment fire tests were performed using kerosene and Jet A-1 as fire sources to evaluate the relationship between flame temperature and opening size. The tests were performed for a fire caused by the release of kerosene owing to vehicle impact, and for a fire caused by the release of Jet-A-1 owing to airplane collision. The compartment fire tests were performed using a 1/3-scale model of a metal storage cask when the flame temperature was deemed to be the highest. We found the combustion time of Jet-A-1 to be shorter than that of kerosene, and consequently, the flame temperature of Jet-A-1 was measured to be higher than that of kerosene. When the opening was installed on the compartment roof, even though the area of the opening was small, the ventilation factor was large, resulting in a high flame temperature and long combustion. Therefore, the position of the opening is a crucial factor that affects the flame temperature. When the metal storage cask was stored in the compartment, the flame temperature decreased proportionally with the energy that the metal storage cask received from the flame.

EXPERIMENTAL STUDY ON THE HEAVY-DUTY GAS TURBINE COMBUSTOR (산업용 가스터빈 연소기에 대한 실험적 연구)

  • Antonovsky, V.;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.142-149
    • /
    • 2000
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed in the scale 1:1. The model experiments were executed at a pressure smaller than in the real gas turbine. The combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure, and NOx emission were measured at partial and full load for both model and on-site testing. The comparison of these items of information, received on similar modes in the stand and field tests, has allowed the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

An Experimental Study On Characteristics of Flame and Combustion Stability of Coaxial Jet Injectors (동축형 제트 분사기의 화염 및 연소 안정성 특성에 관한 실험적 연구)

  • Son, Jinwoo;Min, Yong Ho;Sohn, Chae Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.2
    • /
    • pp.15-21
    • /
    • 2016
  • Flame characteristics and combustion stability of a swirl coaxial injector are studied experimentally. Characteristics of flame and combustion instability are analyzed with the parameter of MFR (momentum flux ratio) using hexane instead of kerosene. Flame patterns of blue and yellow are changed with variable MFR. Combustion instabilities are measured and analyzed by adopting a model chamber. Combustion instability mapping is made by evaluating damping factor at the 2 L (second longitudinal) mode with variable MFR in 63 cases for operating condition.

The Effect of Swirl on the Structure of Concentric Laminar Jet Diffusion Flame (동축분류 층류제트 확산화염의 구조에 미치는 선회의 영향)

  • 김호영;민성기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.578-588
    • /
    • 1992
  • In order to predict the effect of swirl on the structure of concentric laminar jet diffusion flame, present study examined the effect of swirl on the flame characteristics by numerical numerical analysis through theoretical model. The theoretical model has been developed for the co-axial laminar jet flame such that the fuel and air are supplying with swirl through inner and outer co-axial tube respectively. For the parametric study, swirl number, Reynolds number of fuel and air and directions of swirl are chosen as important parametes. The results of study show that the flame with width and shorter length is formed by larger swirl number. The important factor of the flame shape is the recirculating zone formed around jet axis near the exit of nozzle. In case of weak swirl, the effect of directions of swirl is not appeared. However, for the strong swirl, the flame with shorter length are appeared in case of counter-swirl compared with the case of co-swirl.

Evaluation of a New Workplace Protection Factor―Measuring Method for Filtering Facepiece Respirator

  • Sun, Chenchen;Thelen, Christoph;Sanz, Iris Sancho;Wittmann, Andreas
    • Safety and Health at Work
    • /
    • v.11 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • Background: This study aims to assess whether the TSI PortaCount (Model 8020) is a measuring instrument comparable with the flame photometer. This would provide an indication for the suitability of the PortaCount for determining the workplace protection factor for particulate filtering facepiece respirators. Methods: The PortaCount (with and without the N95-CompanionTM) was compared with a stationary flame photometer from Moores (Wallisdown) Ltd (Type 1100), which is a measuring instrument used in the procedure for determining the total inward leakage of the particulate filtering facepiece respirator in the European Standard. Penetration levels of sodium chloride aerosol through sample respirators of two brands (A and B) were determined by the two measuring systems under laboratory conditions. For each brand, thirty-six measurements were conducted. The samples were split into groups according to their protection level, conditioning before testing, and aerosol concentration. The relationship between the gauged data from two measuring systems was determined. In addition, the particle size distribution inside the respirator and outside the respirator was documented. Linear regression analysis was used to calculate the association between the PortaCount (with and without the N95-CompanionTM) and the flame photometer. Results: A linear relationship was found between the raw data scaled with the PortaCount (without N95-CompanionTM) and the data detected by the flame photometer (R2 = 0.9704) under all test conditions. The distribution of particle size was found to be the same inside and outside the respirator in almost all cases. Conclusion: Based on the obtained data, the PortaCount may be applicable for the determination of workplace protection factor.

Chemical Reactions in the Coal-Methane-Air Flame (석탄화염내 화학반응에 관한 연구)

  • 박호영;안달홍;김종진
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.166-177
    • /
    • 2002
  • The present study is described of the flame structure of one-dimensional, flat, premixed, laminar, coal-air flame with some addition of methane for the flame stability. A low pressure burner operating at a combustion pressure of 0.3 arm was employed in order to extend the reaction zone. Predicted results from the models considered in the present study are compared with experimental results. Comparisons are included gas temperatures, species concentrations, char analysis and measured burning velocity. Among the models, Model II $I^{*}$-d, which specified devolatilization rate constants and a char surface area factor S=4, resulted in good agreement within the present experimental ranges. The results of char analysis suggest that the extent of the reaction occurring on the panicle might be underestimated in the model so that the char surface area should be increased. A value of 4 for this factor was given by sensitivity analysis of change in char surface area. Again, model II $I^{*}$-d gave satisfactory predictions of burning velocities over most of the experimental range studied. It has been clearly shown that the particle diameter appreciably affects the rates of devolatilisation and char oxidation through the effects of thermal lag and volumetric reactive surface area, consequently laminar burning velocity.ity.