• 제목/요약/키워드: Fixture Design

검색결과 208건 처리시간 0.025초

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY)

  • 김병옥;홍국선;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구 (Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads)

  • 지영덕;이재환;오상천
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.417-429
    • /
    • 2009
  • 골유착성 임플란트가 소개된 이후로 부분 및 무치악 부위에서 사용되어 높은 성공률과 함께 예지성 있는 결과를 보여주는 치료방법으로 인정받고 있다. 그러나 국내에서 개발된 임플란트에 대해서는 임상적이고 객관적인 연구 자료가 불충분하다. 본 연구에서는 31명의 환자에게서 임플란트 경부에 미세나사를 지닌 임플란트 식립 후 평균 21개월의 기간 동안 임플란트의 생존율에 관한 조사를 시행하였고 부하가 가해지는 시점을 기준으로 12개월 간 변연골의 변화를 파노라마사진을 이용하여 측정 관찰하여 다음의 결과를 도출하였다. 총 96개의 임플란트에서 3개의 임플란트가 실패하여 96.9%의 생존율을 보였다. 50대 환자에서 85.7%로 가장 작은 생존율을 보였으며 성별 및 연령에 따른 생존율 및 변연골 흡수량에 대한 통계적 유의성은 존재하지 않았다. 상악에서는 95.7% 하악에서는 100%의 생존율을 보였다. 골이식 여부, 보철물의 종류, 매식체의 길이 및 직경에 따른 생존율의 차이는 통계적으로 유의한 차이를 보이지 않았다. 기능 부하 후 임플란트 변연골 흡수량은 단일 금관 보철물이 연결 고정 보철물에 비해 증가된 양상을 보였으나 임플란트의 직경, 길이, 골이식의 유무, 식립위치에 의해서는 통계적으로 유의한 차이를 보이지 않았다. 이 연구를 통해 경부에 미세나사를 지닌 임플란트 식립 후에 임플란트 변연골 흡수량은 비교적 적게 일어났으며 또한 안정적으로 유지되는 것이 관찰될 수 있었고 이에 따른 장기적인 추적관찰이 필요할 것으로 사료된다.

탄소배출권용 AIoT 고효율 가로등 성능분석 연구 (A Study on the Performance Analysis of AIoT High-Efficiency Streetlamp for Carbon Emissions)

  • 박승호;신성욱;유경선
    • 미래기술융합논문지
    • /
    • 제2권4호
    • /
    • pp.13-19
    • /
    • 2023
  • 파리기후변화협약(UNFCCC, 2015) 체결에 따라 선진국뿐만 아니라 개발도상국을 포함하는 포괄적 참여를 통해 전 세계가 온실가스 감축 활동을 확대하고 있다. 세계 주요국은 탄소배출권 시장을 통한 탄소배출 총량규제의 효과에 많은 기대를 걸고 있다. 그러나 탄소배출권을 얻기 위해서는 정량적인 탄소저감량 데이터를 바탕으로 제3자 검증이 필요하다. 이에 본 논문에서는 탄소배출권용 AIoT 고효율 가로등을 개발하여 등기구의 광효율을 측정하는 성능분석 연구를 진행했다. 탄소배출권을 얻기 위해 고효율 LED PKG를 사용하며 고전압용 PFC를 자체 개발하고 통신이 가능한 고효율의 등기구를 개발했다. 통신을 위해 등기구와 Gateway간 2.4GHz LoRa 방식을 채택했다. 한국 도로공사 표준 가로등 Type A, B, C 시뮬레이션을 통하여 렌즈 설계를 진행했다. 가로등의 성능은 공인 성적기관의 광효율 측정을 통하여 기존 타제품 대비 고효율의 성능을 검증하였으며, 이를 통한 전기에너지 절감으로 탄소배출권을 획득할 것으로 기대된다.

도시공원 야간경관의 조성 과정과 실태 분석 - 여의도공원을 중심으로 - (Analysis of Urban Park Nightscape based on the Design-Construction Process and Current Status - Focused on Yeouido Park -)

  • 김현근;김아연
    • 한국조경학회지
    • /
    • 제46권2호
    • /
    • pp.14-26
    • /
    • 2018
  • 빛은 인간 생활을 결정하는 중요한 요소이다. 인류가 인공적으로 빛을 다룰 수 있게 된 이래 조명은 도시의 야간문화와 경관을 획기적으로 바꾸어 놓았다. 야간 경관은 도시의 정체성에 지대한 영향을 미친다. 시민들의 야간 활동이 늘어나면서 조명에 대한 다양한 요구가 늘어나는 추세이지만, 정작 경관을 다루는 조경 분야의 계획 설계과정에서 조명계획은 비중 있게 다루어지지 않았다. 본 연구는 우리나라 도시공원의 야간경관의 실태를 분석하기 위해 공원의 계획 및 조성 과정과 제도적 측면의 문제점을 파악하고, 여의도공원을 대상으로 도면 분석과 현장 조사를 통해 문제점을 도출하였다. 현재 도시공원의 야간경관과 관련한 실태 분석의 결과는 다음과 같다. 첫째, 공원의 계획 설계 과정에서 조명계획은 설비 분야에 포함되어 개략적인 수준으로만 다루어져왔고, 이는 실제 공원의 단조로운 야간경관을 초래했다고 볼 수 있다. 따라서 공원의 분석-계획-설계-시공-관리 과정에서 야간경관의 연출을 적극적으로 수용할 수 있는 방법론이 개발되어야할 것이다. 둘째, 현재 도시공원에 적용 가능한 기준은 한국산업규격(KS A 3011)의 수평조도 규정에 그치고 있어 야간경관 평가와 계획의 세부 기준 항목을 다양하게 개발할 필요가 있다. 셋째, 성장하는 수목과 복합적인 자연생태계의 특성을 고려할 수 있는 야간경관 설계 및 관리 방안이 필요하다. 넷째, 공원의 공간별 특성에 맞는 세부 디자인 가이드라인과 관련 기준이 필요하다.

간접유치장치 설계변화에 따른 하악유리단 국소의치의 광탄성 응력분석 (A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL - EXTENSION REMOVABLE PARTIAL DENTURES WITH VARIOUSLY DESIGNEO INDIRECT RETAINERS)

  • 강승종;계기성
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.183-197
    • /
    • 1990
  • The purpose of this study was to analyse the magnitude and distribution of stresses using a Photoelastic model from and distal - extension removable partial dentures With four designed indirect retainers. The designs of the indirect retainers were as follows : Design No. 1 : Aker's clasp on 1st bicuspid with no indirect retainer. Design No. 2 : Aker's clasp on 1st bicuspid with indirect retainer on canine. Design No. 3 : Extension of the reciprocal arm of Aker's clasp toward incisal rest on canine. Design No. 4 : Connection with the indirect retainer as in No. 2 and extension of reciprocal arm of Aker' s clasp. A photoelastic model was made of the epoxy resin(PL - 1) and hardner(PLH - 1) and coated with plastic cement -1(PC -1) at the lingual surface of the epoxy model and set with chrome - cobalt partial dentures. A unilateral vertical load of 10kg to the right 1st molar and a vertical load of 10kg to the middle portion of the metal bar crossing both the 1st molars of the right and left, were applied. With the use of specially designed jig, fixture; loading device and the reflective circular polariscope, we obtained the following results : 1. When the unilateral vertical load and the vertical load of the middle portion of the metal bar were applied, design No. 2, 3 and 4 exhibited the higher stress concentration at the root apices and their surrounding tissues of the primary and secondary abutment teeth. 2. When the unilateral vertical load applied to design No. 2,3 and 4 the root apices of the primary and secondary abutment teeth and their surrounding tissues and the nonloaded side of edentulous area exhibited and even stress distribution. 3. When the vertical load was applied, the stress concentration fringe in the primary and secondary abutment teeth was in the order of No. 1,4,2 and 3. 4. No.1 and 4 exhibited the higher distrorted stress concentration at the primary teeth and the edentulous area in the nonloaded side. 5. No.2 design reduced the stresses at the apices of the alveoli of the primary abutment teeth bilaterally as well as on the crest of the residual ridge on the nonloaded side. 6. No. 2 design exhibited the most favorable stress distribution.

  • PDF

Co90Fe10/SiO2 Multilayer를 이용한 GHz 자성박막 인덕터 설계 및 제작에 관한 연구 (A Study on the Design and Fabrication of GHz Magnetic Thin Film Inductor Utilizing Co90Fe10/SiO2 Multilayer)

  • 공기준;윤의중;진현준;박노경;문대철
    • 한국통신학회논문지
    • /
    • 제25권5B호
    • /
    • pp.985-991
    • /
    • 2000
  • 본 논문에서는 인덕터의 면적을 극소화시키고 인덕턴스와 Q값을 극대화시키기 위한 최적구조의 2GHz 자성박막 인덕터를 설계하고 제작하였다. Eddy-current 표피효과를 위해서 Co90Fe10와 SiO2의 multilayer를 사용하고, multilayer를 적용한 새로운 lumped 소자모델을 고려하여 최적설계를 수행하였다. 2GHz에서 동작하는 새로운 자성박막 인덕터는 photo-lithography와 lift-off기술을 이용하여 Si 기판위에 제작되었다. 50개 이상의 동일한 인덕터들의 주파수 특성은 RF Impedance Analyzer로, 자기공진주파수는 Vector Network 분석기(HP8510)로 측정되었다. 개발된 인덕터들은 1.8~2.3GHz 범위의 자기공진주파수, 47~68nH 범위의 L값, 그리고 1GHz이상의 주파수에서 70~80정도의 Q값을 가지므로 L과 Q가 극대화된 아주 우수한 최적구조의 소형(면적=30.8$\times$30.8mil2) 박막인덕터가 성공적으로 제작되었다.

  • PDF

개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구 (A study on simplified procedure of enhanced designed implant drill)

  • 윤지훈;전계록;윤미정;허중보;정창모
    • 대한치과의사협회지
    • /
    • 제53권5호
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

뮤지컬 공연을 위한 프로시니엄 형식의 무대공간 구성에 대한 연구 (A Study on the Proscenium Type Stage Space Composition for Musical Performance)

  • 전용석
    • 한국실내디자인학회논문집
    • /
    • 제25권5호
    • /
    • pp.42-54
    • /
    • 2016
  • The purpose of this study is to provide a reference for stage planning by analyzing current state of major theaters' stage space and understanding feedback from directors belonged to theaters. Each room in total 18 theaters' stage facilities was measured and their usage and requirements were analyzed on the spot. In addition, each director provided their experiential knowledge about appropriate stage composition for musical performance. The findings are as follow: under stage machinery is not needed for musical. Tour teams prefer to use their own show-deck for set conversion. On the other hand, over stage flying system needs to be able to deal with dense, fast, and accurate scene change. The size and location of the motor room needs to be carefully considered. The number of set battens is directly linked up with the size of the motor room, which should be located lower than the gridiron. As stage sets get bigger and complicated, the number of works at the gridiron is also increasing. The grating floor has to have enough strength coping with machines lifting heavy sets. Most sound control for musical performance is being done at F.O.H. these days rather that in the sound control room. It should equip enough work area and related infra especially for tour teams. 1st gallery needs to have enough effective width, power infra for lighting fixture, and strong guardrail. Lastly, the whole process of parking-unloading-transporting equipments and sets from loading dock to stage and vice versa needs to be efficient, and this has to be carefully considered from early stage of planning.

식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션 (3D Simulation of Dental Implant Surgery Using Surgical Guide Stents)

  • 박형욱;김명수;박형준
    • 한국CDE학회논문집
    • /
    • 제16권3호
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.