• Title/Summary/Keyword: Fixed length

Search Result 1,091, Processing Time 0.028 seconds

On the Finite-world-length Effects in fast DCT Algorithms (고속DCT변환 방식의 정수형 연산에 관한 연구)

  • 전준현;고종석;김성대;김재균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.4
    • /
    • pp.309-324
    • /
    • 1987
  • In recent years has been an increasing interest with respect to using the discrete cosine transform(DCT) of which performance is found close to that of the Karhumen-Loeve transform, known to be optimal in the area of digital image processing for tha purpose of the image data compression. Among most of reported algorithms aimed at lowering the coputation complexity. Chen's algorithm is is found to be most popular, Recently, Lee proposed a now algorithm of which the computational complexity is lower than that of Chen's. but its performance is significantly degraded by FWL(Finite-Word-Lenght) effects as a result of employinga a fixed-poing arithmetic. In this paper performance evaluation of these two algorithms and error analysis of FWL effect are described. Also a scaling technique which we call Up & Down-scaling is proposed to allevaiate a performance degradation due to fixed-point arithmetic. When the 16x16point 2DCT is applied on image data and a 16-bit fixed-point arithmetic is employed, both the analysis and simulation show that is colse to that of Chen's.

  • PDF

Design Optimization of Passive Control Devices for Dynamic Stall Control (동적실속 수동제어장치 최적설계)

  • Joo, Wan-Don;Lee, Bo-Sung;Yee, Kwan-Jung;Lee, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.11-19
    • /
    • 2005
  • In order to improve dynamic stall characteristics of an oscillating airfoil, optimal design has been performed for fixed nose droop and Gurney flap. Fixed nose droop is known to be very effective to improve pitching moment characteristics but may cause degeneration of aerodynamic lift at the same time. On the other hand, Gurney flap has the opposite characteristics. For fixed nose droop, location and angle are chosen as design variables, while length is defined as design variable for Gurney flap. Higher order response surface methodology and sensitivity based optimal design method are employed to handle highly nonlinear problem such as dynamic stall. Optimal design has been performed so that lift and pitching moment are simultaneously improved. The design results show that aerodynamic characteristics can be remarkably improved through present design approach and the present passive control method is as good as active control method which combines variable nose droop and Gurney flap.

Adsorption Characteristics of Malachite Green on Zeolite (제올라이트에 의한 말라카이트 그린의 흡착특성)

  • Lee, Jong-Jib;Um, Myeong-Heon
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • Malachite green is used a dye but malachite green is harmful toxic substance. In this study, the adsorption characteristics of zeolite has been investigated for the adsorption of malachite green dissolved in water. The effects of initial dye concentration, contact time, pH and temperature on adsorption of malachite green by a fixed amount of zeolite have been studied in batch adsorber and fixed bed. The adsorption equilibrium data are successfully fitted to the Freundlich isotherm equation in the temperature range from 25 to $45^{\circ}C$. The estimated values of k and ${\beta}$ are 23.60-46.88, 0.225-0.347, respectively. The mechanism of the adsorption process was determined from the intraparticle diffusion model. The effects of the operation conditions of the fixed bed on the breakthrough curve were investigated. When the inlet concentration and initial flow rate of malachite green are increased, the corresponding adsorption breaktime appears to decrease. Breaktime increased with increasing bed height and length of adsorption zone showed similar patterns.

Monitoring of tension force and load transfer of ground anchor by using optical FBG sensors embedded tendon

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Hyun-Woo;Kim, Jae-Min
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.303-317
    • /
    • 2011
  • A specially designed tendon, which is proposed by embedding an FBG sensor into the center king cable of a 7-wire strand tendon, was applied to monitor the prestress force and load transfer of ground anchor. A series of tensile tests and a model pullout test were performed to verify the feasibility of the proposed smart tendon as a measuring sensor of tension force and load transfer along the tendon. The smart tendon has proven to be very effective for monitoring prestress force and load transfer by measuring the strain change of the tendon at the free part and the fixed part of ground anchor, respectively. Two 11.5 m long proto-type ground anchors were made simply by replacing a tendon with the proposed smart tendon and prestress forces of each anchor were monitored during the loading-unloading step using both FBG sensor embedded in the smart tendon and the conventional load cell. By comparing the prestress forces measured by the smart tendon and load cell, it was found that the prestress force monitored from the FBG sensor located at the free part is comparable to that measured from the conventional load cell. Furthermore, the load transfer of prestressing force at the tendon-grout interface was clearly measured from the FBGs distributed along the fixed part. From these pullout tests, the proposed smart tendon is not only expected to be an alternative monitoring tool for measuring prestress force from the introducing stage to the long-term period for health monitoring of the ground anchor but also can be used to improve design practice through determining the economic fixed length by practically measuring the load transfer depth.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

Wind-Resistant Safety Reviews of Traffic Signal Structures by Wind Tunnel Tests (풍동실험을 통한 교통신호 구조물의 내풍 안전성 검토)

  • Taik-Nyung Huh
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.833-840
    • /
    • 2024
  • According to recent data from the Korea Meteorological Administration(KMA), the frequency of typhoons around the Korea Peninsula is almost unchanged, but the intensity is on the rise due to climate change. A typhoon that has become so powerful can cause partial or complete damage to the traffic signal structures, limiting the operation of the vehicle and causing traffic congestion. If the traffic signal structure fails to function properly due to the influence of the typhoon, not only the v ehicle operation will be disrupted, but also direct damage to the traffic signal structure will occur. In addition, if the social overhead cost of traffic congestion is included, the recovery cost caused by the typhoon will increase to an extent that it is difficult to estimate. Therefore, in this study, a wind tunnel experiment was performed by producing a wind tunnel model of an existing fixed traffic signal structure and a traffic signal structure in which signs and traffic lights are hinged. Also, The fixed and hinge structures were modeled as 3D finite elements, and wind-resistant analysis was performed by wind speed, and, wind-resistant safety of traffic signal structures were analyzed and examined through wind-resistant analyses. From the comparative analysis of the results of experiment and FE analysis, it was known that the stress reduction rate of the hinge connection structure was at least 30% compared to that of the fixed connection structure from the results of the wind tunnel experiment and FE analysis. And As a result of finite element analysis for the maximum design wind speed of 50m/s, it was found that the maximum stress generated in the existing structure exceeded all the yield stress, but the maximum stress of the hinge connection structure was within the yield stress. Finally The hinge connection structure showed a relatively large stress reduction rate as the wind speed increased and the length of the lateral beam was shorter at the same wind speed.

Fixed-Point Modeling and Performance Analysis of a SIFT Keypoints Localization Algorithm for SoC Hardware Design (SoC 하드웨어 설계를 위한 SIFT 특징점 위치 결정 알고리즘의 고정 소수점 모델링 및 성능 분석)

  • Park, Chan-Ill;Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.49-59
    • /
    • 2008
  • SIFT(Scale Invariant Feature Transform) is an algorithm to extract vectors at pixels around keypoints, in which the pixel colors are very different from neighbors, such as vortices and edges of an object. The SIFT algorithm is being actively researched for various image processing applications including 3-D image constructions, and its most computation-intensive stage is a keypoint localization. In this paper, we develope a fixed-point model of the keypoint localization and propose its efficient hardware architecture for embedded applications. The bit-length of key variables are determined based on two performance measures: localization accuracy and error rate. Comparing with the original algorithm (implemented in Matlab), the accuracy and error rate of the proposed fixed point model are 93.57% and 2.72% respectively. In addition, we found that most of missing keypoints appeared at the edges of an object which are not very important in the case of keypoints matching. We estimate that the hardware implementation will give processing speed of $10{\sim}15\;frame/sec$, while its fixed point implementation on Pentium Core2Duo (2.13 GHz) and ARM9 (400 MHz) takes 10 seconds and one hour each to process a frame.

Reliability and Validity of the Behavioral Observation Method for Assessing Low Back Pain in Patients with Spinal Diseases (척추질환자의 요통사정을 위한 통증행위 관찰법의 신뢰도 및 타당도 검정)

  • Yoon, Ho-Soon;Lee, Eun-Ok
    • Journal of muscle and joint health
    • /
    • v.1 no.1
    • /
    • pp.97-115
    • /
    • 1994
  • The purpose of this study was to examine the reliability and validity of the observed behaviors of subjects who suffered from low back pain with spinal diseases, Thirty two low back pain patients admitted on the neurosurgical unit in an army hospital were compared with 30 normal controls belonged to an army unit, by means of matching the age, hight and weight. Observed pain behaviors were developed by the researcher on the bases of literature and patient observation. This tool consists of 18 behaviors seperated into two major groups : mutually exclusive and concomittent behaviors. The mutually exclusive behaviors included coding cathegories for 6. body motions assumed by the subjects during the observation session. These 6 standardized motions consisted of sitting from standing first, and serially tying down, reclining, sitting again, and then standing, 6 steps walking. Concomittent behaviors consisted of 12 observable patterns that can be observed systematically from the face, grimacing, bracing, rubbing, walking with arms fixed, support with hands on sitting or standing, guarded movement, limping, unbalaced weightbearing, stopped movement from tying position to sitting, sighing and graoning. Subjects were videotrecorded as they performed a 6-standardized sequence of motions, simultanously researcher measured the time spent performing each motion and step length. Patients were asked torate their subjective pain score on the 10 mm graphic rating scale ranging from 'no pain' to 'sever pain'. For scoring of the pain behaviors, two trained nursing officiers independently and simutanously viewwd each videorecording and checked subject 'pain behaviors at the observational item checklist. The result of the study are summarized as follows : 1. Reability of the observational tool was a=.845. 2. Spearman's rho and percentage agreement were p=.97 and 81.7 persent respectively, that indicate adequate interrater reability of this tool. 3. The sensitivity rate of the tool was .875 while specificity rate .866 for differentiating patient from the normal. 4. When difference in the objective pain indices between patient group and control were compared, there was significant difference of all indices, such as pain behavior(t=7.71, p=.0001). spent time performing motion(t=14.2, p=.0001), step length (t=-10.72, p=.0001). 5. There were differences in the objective indices the subjective pain subgroups (low, medium, high). Differences in the mean score of objective pain behavior (F=6.376. p=.005) and spent time for moyion(F=4.631, p=.018). But there were no significant differences in the step length among the subgroups(F=.667, p=.521). 6. Highly correlated pain behavior items wiyh subjective pain score were 'stopped movement from lying position to sitting', 'limping', 'support with hands on sitting or standing', 'bracing', 'guarding' and 'walking with arms fixed'. In summary, although some of rho behavior items such as sighing and groaning in this study could not be observed because of videotaped datd, the reliability and validity of the over all observation method were satifactory. Thus, the results of the present study demonstrate rye potetional utility of the tool in assessing objective pain complementing self-reported pain in low back pain patients.

  • PDF

FFT/IFFT IP Generator for OFDM Modems (OFDM 모뎀용 FFT/IFFT IP 자동 생성기)

  • Lee Jin-Woo;Shin Kyung-Wook;Kim Jong-Whan;Baek Young-Seok;Eo Ik-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.3A
    • /
    • pp.368-376
    • /
    • 2006
  • This paper describes a Fcore_GenSim(Parameterized FFT Core Generation & Simulation Program), which can be used as an essential If(Intellectual Property) in various OFDM modem designs. The Fcore_Gensim is composed of two parts, a parameterized core generator(PFFT_CoreGen) that generates Verilog-HDL models of FFT cores, and a fixed-point FFT simulator(FXP_FFTSim) which can be used to estimate the SQNR performance of the generated cores. The parameters that can be specified for core generation are FFT length in the range of 64 ~2048-point and word-lengths of input/output/internal/twiddle data in the range of 8-b "24-b with 2-b step. Total 43,659 FFT cores can be generated by Fcore_Gensim. In addition, CBFP(Convergent Block Floating Point) scaling can be optionally specified. To achieve an optimized hardware and SQNR performance of the generated core, a hybrid structure of R2SDF and R2SDC stages and a hybrid algorithm of radix-2, radix-2/4, radix-2/4/8 are adopted according to FFT length and CBFP scaling.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF