• 제목/요약/키워드: Fixed Reference

검색결과 435건 처리시간 0.03초

Ro-Ro Space 화재진압성능 평가를 위한 시험절차 및 성능요건 (Test method and Requirements of Water-Based Fire-Fighting Systems for RO-RO Spaces and Special Category Spaces)

  • 곽지현;이두형;김영한
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.199-200
    • /
    • 2012
  • Test method and requirements of fixed water-based fire-fighting systems for Ro-Ro spaces and special category spaces were introduced for research engineer's reference.

  • PDF

한 대의 USB port 카메라를 이용한 물체추적 과 3차원 정보 추출 (3D Position Analysis and Tracking of an Object using Monocular USB port Camera)

  • 이동엽;이동활;배종일;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.277-277
    • /
    • 2000
  • This paper's purpose obtain information of three dimension using a camera. This system embody to know the height of object using triangle method between reference point of circumstance and object. As I use java program, it is possible to make system regardless of operating system, set up the system. By using comportable USB port camera, we used to everywhere without the capture board. We can use the internet by using the java's JMF and applet everywhere, we regard the camera as fixed.

  • PDF

자계벡터 가속법에 기초한 유도 전동기의 구동 (A New Induction Motor Drive Based on the Flux Vector Acceleration Method)

  • 정승환;홍순일;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.701-702
    • /
    • 2006
  • A novel control strategy for the induction motor drive, based on the field acceleration method, is presented. The torque is controlled through variations of the stator flux angular velocity. The stator flux is controlled by using a feed forward control scheme, with the stator flux reference vector adjusted so as to obtain the fixed rotor flux amplitude.

  • PDF

신경회로망에 의한 정현파 전류 추종 인버어터의 제어 (Sinusoidal Current Tracking Inverter Control with Neural Networks)

  • 배상준;이달해;김동희
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.219-226
    • /
    • 1994
  • Sinusoidal current tracking inverters have substantial advantages in high performance acdrive systems and various control strategies for the inverter have been proposed by several researchers. This paper develops a sinusoidal current tracking inverter with neural networks. The neural network are trained to follow a set of reference current waveforms by erro back propagation algorithm and the trained neural networks are applied to the current control. We compare neural networks method with conventional current control methods (fixed band and sinusiidal band hystersis methods) and simulation results are presented.

  • PDF

주기적 송신원 추출과 참조 송신원 부분집합을 이용한 완전 파형 역산 (Full Waveform Inversion using a Cyclic-shot Subsampling and a Reference-shot Subset)

  • 조상훈;하완수
    • 지구물리와물리탐사
    • /
    • 제22권2호
    • /
    • pp.49-55
    • /
    • 2019
  • 본 연구에서는 주기적 송신원 추출 기법을 사용한 완전 파형 역산 시 목적함수의 안정적인 수렴을 위해 참조 송신원 부분집합을 사용하는 방법을 제안하였다. 완전 파형 역산은 반복적인 파동 전파 모델링을 통해 수행되며, 송신원 개수가 증가할수록 계산 시간이 증가하게 된다. 완전 파형 역산의 계산량을 줄이기 위한 기법들 중 하나로, 주기적 송신원 추출 기법을 사용할 수 있지만 이 경우 역산 초기부터 목적함수가 진동하며 수렴하기 때문에 수렴 판별에 문제가 생기게 된다. 이러한 문제를 해결하고자 본 연구에서는 주기적 송신원 추출 기법을 이용해 모델을 갱신하되, 고정된 참조 송신원 부분집합을 이용해 목적함수를 계산하는 방법을 제안하였다. Marmousi 속도 모델을 이용한 완전 파형 역산 예제를 통해 참조 송신원 부분집합을 이용하면 주기적 송신원 추출 기법을 사용하더라도 목적함수가 안정적으로 수렴할 수 있음을 확인하였다.

구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구 (A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS)

  • 강한중;동진근;오상천;이해형;송기창
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

효율적인 참조 메모리 사용을 위한 블록기반 적응적 비트할당 알고리즘 (Block-based Adaptive Bit Allocation for Reference Memory Reduction)

  • 박시내;남정학;심동규;주영훈;김용석;김현문
    • 대한전자공학회논문지SP
    • /
    • 제46권3호
    • /
    • pp.68-74
    • /
    • 2009
  • 본 논문에서는 비디오 부호화기와 복호화기의 참조 영상 버퍼와 메모리 대역폭을 효과적으로 줄이는 방법을 제안한다. 일반적인 비디오 코덱에서 코딩의 효율을 높이기 위하여 이전 프레임들을 참조하는 방법을 많이 사용하는데, 최근에는 메모리 사용 및 메모리와 프로세서 간의 데이터 대역폭의 효율을 높이기 위하여 참조 프레임을 압축하여 저장하는 방법이 연구되고 있다. 이 방법은 이미 압축 및 복원 과정을 통해 열화가 생긴 참조 영상에 대하여 재 압축을 실행하고, 또 기존의 압축 코덱 내부에 부호화기와 복호화기가 추가되는 경우이기 때문에, 화질의 열화를 최소화하면서 복잡도가 낮은 코덱이 요구된다. 이에 관련된 대부분의 연구는 화질의 열화를 최소화하면서 효과적인 재압축을 할 수 있는 방향으로 진행되며 보통 양자화를 위해 고정길이 비트할당 방법을 사용한다. 본 논문에서는 영상의 특성을 고려한 적응적 블록단위 최대-최소 양자화를 통해 복잡도가 낮으면서 화질의 열화를 최소화 한 방법을 제안한다 제안한 방법에서는 $8{\times}8$ 크기의 블록을 기본 처리 단위로 하여 메모리 접근성을 용이하게 하면서, $8{\times}8$ 블록 내부의 $4{\times}4$ 블록 단위로 적응적인 양자화를 적용한다. 실험결과 기존의 고정길이 비트 할당을 통한 재 압축 방법에 대하여 BD-bitrate 관점에서 평균 1.7%, BD-PSNR 관점에서 평균0.03%의 성능향상을 얻을 수 있었다.

전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택 (Selection of mAs with Using Table Strap in Computed Tomography Scan)

  • 이용현;안형택
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

Effects of the location and size of web openings on shear behavior of clamped-clamped reinforced concrete beams

  • Ceyhun Aksoylu;Yasin Onuralp Ozkilic;Ibrahim Y. Hakeem;Ilker Kalkan
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.251-264
    • /
    • 2024
  • The present study pertains to the effects of variations in the location and size of drilled web openings on the behavior of fixed-fixed reinforced concrete (RC) beams. For this purpose, a reference bending beam with a transverse opening in each half span was tested to failure. Later, the same beam was modeled and analyzed with the help of finite element software using ABAQUS. Upon achieving close agreement between the experimental and numerical results, the location and size of the web opening were altered to uncover the effects of these factors on the shear strength and load-deflection behavior of RC beams. The experimental failure mode of the tested beam and the numerical results were also verified by theoretical calculations. In numerical analysis, when compared to the reference (D0) specimen, if the distance of the opening center from the support is 0 or h or 2h, reduction in load-bearing capacity of 1.5%-22.8% or 2.0%-11.3% or is 4.1%-40.7%. In other words, both the numerical analyses and theoretical calculations indicated that the beam behavior shifted from shear-controlled to flexure-controlled as the openings approached the supports. Furthermore, the deformation capacities, energy absorption values, and the ductilities of the beams with different opening diameters also increased with the decreasing distance of the opening from supports. Web compression failure was shown to be the predominant mode of failure of beams with large diameters due to the lack of sufficient material in the diagonal compression strut of the beam. The present study indicated that transverse openings with diameters, not exceeding about 1/3 of the entire beam depth, do not cause the premature shear failure of RC beams. Finally, shear damage should be prevented by placing special reinforcements in the areas where such gaps are opened.