• Title/Summary/Keyword: Fixed Plate

Search Result 491, Processing Time 0.026 seconds

Kirschner Wire Fixation for the Treatment of Comminuted Zygomatic Fractures

  • Kang, Dai-Hun;Jung, Dong-Woo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, JunHo;Chung, Kyu Jin
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.119-124
    • /
    • 2015
  • Background: The Kirschner wire (K-wire) technique allows stable fixation of bone fragments without periosteal dissection, which often lead to bone segment scattering and loss. The authors used the K-wire fixation to simplify the treatment of laborious comminuted zygomatic bone fracture and report outcomes following the operation. Methods: A single-institution retrospective review was performed for all patients with comminuted zygomatic bone fractures between January 2010 and December 2013. In each patient, the zygoma was reduced and fixed with K-wire, which was drilled from the cheek bone and into the contralateral nasal cavity. For severely displaced fractures, the zygomaticofrontal suture was first fixated with a microplate and the K-wire was used to increase the stability of fixation. Each wire was removed approximately 4 weeks after surgery. Surgical outcomes were evaluated for malar eminence, cheek symmetry, K-wire site scar, and complications (based on a 4-point scale from 0 to 3, where 0 point is 'poor' and 3 points is 'excellent'). Results: The review identified 25 patients meeting inclusion criteria (21 men and 4 women). The mean age was 52 years (range, 15-73 years). The mean follow up duration was 6.2 months. The mean operation time was 21 minutes for K-wire alone (n=7) and 52 minutes for K-wire and plate fixation (n=18). Patients who had received K-wire only fixation had severe underlying diseases or accompanying injuries. The mean postoperative evaluation scores were 2.8 for malar contour and 2.7 for K-wire site scars. The mean patient satisfaction was 2.7. There was one case of inflammation due to the K-wire. Conclusion: The use of K-wire technique was associated with high patient satisfaction in our review. K-wire fixation technique is useful in patient who require reduction of zygomatic bone fractures in a short operating time.

Identification of mutans streptococci isolated from dental plaque between the bracket and tooth surface in orthodontic patients (교정환자의 브라켓과 치아 경계부에 존재하는 치면세균막내 mutans streptococci 종 및 생물형의 식별)

  • Kim, Mi-Ae;Yoo, So-Young;Kim, Hwa-Sook;Kook, Joong-Ki;Lim, Sung-Hoon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.51-59
    • /
    • 2005
  • The aim of this study was to compare the species and biotypes of mutans streptococci isolated from dental plaques sampled from the interfaces between the bracket aid tooth surface and smooth tooth surfaces In orthodontic patients. Dental plaque was collected from the interfaces between brackets aid teeth (test group), and from smooth tooth surfaces distant from brackets by more that 2mm (control group). The dental plaque collected by a sterilized curette was transferred into a vial of 1 X PBS. The sample in the vial was vigorously vortexed for 1 min and plated ou mitis-salivarius bacitracin (MSB) agar plate using cotton tips. The agar plates were incubated at $37^[\circ}C$ in a candle jar for 2 days, and again incubated for 1 more day at anambient temperature Individual colonies were cultured in TH broth at $37^[\circ}C\;CO_2$ incubator. The PCR-RFLP based on dextranase gene was performed for the identification of mutans streptococci at the species-level For biotyping of mutans streptococci, biochemical tests were performed There was no significant difference of the species of mutans streptococci isolated from both test and control groups However, the biotypes of the mutans streptococci isolated from test and control groups were different. These results may offer the basic data to verify the relationship between the mutans streptococci biotype and enamel decalcification or dental caries in orthodontic patients with fixed appliances.

Enhancement of Performance of Shell and Tube Heat Exchanger Using Pertinent Leakage Flow Between Baffle and Tube Bundles (배플과 관군간의 적정 누설유동을 이용한 쉘-관 열교환기의 성능향상)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, the effects of the leakage flow between the baffle and tube bundles on the performance of a shell and tube heat exchanger (STHE) were examined using the commercial software ANSYS FLUENT v.14. A computational fluid dynamics model was developed for a small STHE with five different cases for the ratio of the leakage cross-sectional area to the baffle cross-sectional area, ranging from 0 to 40%, in order to determine the optimum leakage flow corresponding to the maximum outlet temperature. Using fixed tube wall and inlet temperatures for the shell side of the STHE, the flow and temperature fields were calculated by increasing the Reynolds number from 4952 to 14858. The present results showed that the outlet temperature, pressure drop, and heat transfer coefficient were strongly affected by the leakage flow, as well as the Reynolds number. In contrast with a previous researcher's finding that the leakage flow led to simultaneous decreases in the pressure drop and heat transfer rate, the present study found that the pertinent leakage flow provided momentum in the recirculation zone near the baffle plate and thus led to the maximum outlet temperature, a small pressure drop, and the highest heat transfer rate. The optimum leakage flow was shown in the case with a ratio of 20% among the five different cases.

Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition (점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향)

  • 김철수;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.2
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

Simultaneous Reduction of Contralateral Malar Complex in Cases of Unilateral Zygoma Bone Fracture (편측 관골 골절에서 동시 반대측 관골 축소술)

  • Kim, Peter Chan-Woo;Lee, Byung-Kwon;Bae, Ji-Suk
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.851-860
    • /
    • 2011
  • Purpose: Reduction by simply assembling bones is recognized as treatment for a zygoma fracture. However, in patients who originally had a protruding zygoma, the fractured parts look like malarplasty after the edema subsides, giving a soft impression which patients notice. Thus, we created symmetry through simultaneous contralateral malar reduction in a unilateral zygoma fracture. Methods: In this study, the patients who had surgery between July, 2008 and December, 2009 with admission were object. In 76 patients with a zygoma fracture, the patients with bilateral zygoma fractures were excluded. Among 48 patients who had a reduction only after a unilateral zygoma fracture, the patients hoping for a reduction of their rough protruding zygoma were analyzed with front cephalometry. The study progressed on 22 patients who had simultaneous contralateral malar reduction in a unilateral zygoma fracture with consent. After fixing the fracture, we did a straight zygoma osteotomy through a 1.5 cm intraoral incision. After that, we created symmetry with a special ruler and fixed the broken zygomatic arch with a screw and plate. We evaluated the facial index and satisfaction with a statistical analysis before and after the surgery. Results: In 22 patients, there was no reoperation except for 1 patient who had a zygoma fracture. None of the patients were treated for infection or hematoma. Two patients complained of paresthesia after the malar reduction operation, but this subsided in 4 months. Most of them were satisfied with the malar reduction, especially the women, and we obtained a better mid facial contour with decreased facial width ($p$ <0.05). Conclusion: Existing zygoma fracture surgery focuses on anatomical reduction. However, we need to have a cosmetic viewpoint in fractures as interests of face contour arise. Thus, contralateral malar reduction got a 4.7 (range 0~5) from patients who had malar reduction surgery in our hospital. Although adjusting to all zygoma fractures has limitations, it can be a new method in zygoma fractures when there are limited indications of protruding zygoma and careful attention is given to patients' high demands.

The Changes of Aperture Variation and Hydraulic Conductivity for Compression Variability (압력에 따른 균열 간극변화와 수리전도도 변화 관찰)

  • 채병곤;이철우;정교철;김용제
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.1-11
    • /
    • 2003
  • In order to measure aperture variation dependent on normal stress and to characterize on relationship between aperture variation and hydraulic conductivity this study measured apertures of rock fractures under a high resolution confocal laser scanning microscope (CLSM) with application of five stages of uniaxial normal stresses. From this method the response of aperture can be continuously characterized on one specimen by different loads of normal stress. The results of measurements showed a rough geometry of fracture bearing non-uniform aperture. They also revealed different values of aperture variations according to the load stages on each position along a fracture due to the fracture roughness. Laboratory permeability tests were also conducted to evaluate the changes of permeability coefficients related to the aperture variations by different loads. The results of permeability tests revealed that the hydraulic conductivity was not reduced at a fixed rate with increase of normal load. Moreover, the rates of aperture variations did not match to those of hydraulic conductivity. The hydraulic conductivity calculated in this study did not follow the cubic law, representing that the parallel plate model is not suitable to express the fracture geometry corresponding to the results of aperture measurements under the CLSM.

Parametric Study on Buckling Behavior of Longitudinally Stiffened Curved Panels by Closed-section Ribs (폐단면리브로 보강된 곡판의 국부판좌굴에 관한 변수해석적 연구)

  • Andico, Arriane Nicole P.;Kwak, Jae-Young;Choi, Byung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.714-721
    • /
    • 2018
  • In this study, we investigate a design technology intended to radically increase the buckling strength of vertically curved panels. Recent studies proposed a buckling strength formula which properly reflects the effect on the local plate buckling strength of flat plates when they are stiffened by closed section ribs. Herein, we attempted to quantitatively evaluate this effect on curved panels and to reveal the correlations with the design parameters. The commercial finite element software, ABAQUS, was used to build a three dimensional numerical model and numerical parametric studies were conducted to evaluate the variation of the buckling strength. In the case of flat panels, the local buckling strength of stiffened curved panels increases proportionally with increasing rotational stiffness of the closed-section ribs. After attaining a limiting value, an obvious tendency was found that the local buckling strength of the stiffened curved panel would converge towards a fixed value when the panels are supported along both sides. The parametric studies performed using the influential design parameters confirmed that the estimated partially-restrained curved panel strength is well correlated with the proposed formula.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

The Results of Surgical Treatment of Comminuted Fractures of Distal humerus (원위 상완골 분쇄 골절의 수술적 치료 결과)

  • Cho Nam-Su;Park Sung-Woo;Jung Ki-Yoen;Rhee Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

Clinical Application of Recombinant Human Bone Morphogenetic Protein-2 for Delayed Fractures in Dogs (개에서 골절의 지연유합에 대한 rhBMP-2의 임상적 적용 2례)

  • Kim, Jae-Kyong;Kim, Se-Eun;Go, A-Ra;Kim, Seung-Hyun;Shim, Kyung-Mi;Bae, Chun-Sik;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.412-415
    • /
    • 2012
  • A 1-year-old, castrated male Yorkshire terrier (case 1) and a 7-year-old female Poodle (case 2) presented with delayed union fractures. In case 1, the dog had a fractured right distal radius and ulna. In case 2, the dog had a fractured left distal tibia and fibula. A physical examination and radiographs performed in both dogs revealed delayed union fractures with large gaps. The fracture sites were fixed by bone plate and screws. Autogenous cancellous bone graft was applied into the fracture gap. To encourage rapid bone union, we used matrigel containing $20{\mu}g$ of recombinant human bone morphogenetic protein-2 (rhBMP-2) in the fracture site. Radiographs were taken postoperatively to monitor healing. Rapid bone union was noted in both dogs in long-term radiographs. In case 1, the radiographs revealed that the fracture gaps of the radius and ulna were bridged at 2 weeks. Fracture lines were not observed and normal appearance was restored at 20 weeks. In case 2, the radiographs showed that fracture repair had progressed at 11 weeks. The fractures healed faster than expected in these two cases. The results indicate that rhBMP-2 and matrigel may be effective and useful materials to enhance healing of delayed fractures.