• 제목/요약/키워드: Fixed Factor

검색결과 907건 처리시간 0.024초

2인자 혼합모형의 제약과 비제약 설계에 의한 게이지 R&R 연구의 고찰 (Review of Gauge R&R Studies by Restricted and Unrestricted Design in the Two-Factor Mixed Model)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.657-665
    • /
    • 2009
  • The paper reviews gauge R&R studies by two-factor mixed models including random and fixed factors. The two-factor mixed models include restricted models and unrestricted models considering the interaction of two factors. This study also classifies the models according to the number of factors, and the combination of various factors such as random factor, fixed factor, block factor and repetition type.

  • PDF

분단위 강우자료를 활용한 임의-고정시간 환산계수의 추정 (Conversion Factor Estimates between the Rain Data per Minute and Fixed-Time-Interval)

  • 문영일;오태석;오근택;전시영
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.679-682
    • /
    • 2008
  • Probability precipitation is one of the most important factor for designing the hydrology structures. Probability precipitation is calculated based on the frequency analysis on each durations of annual maximum rainfall data. For frequency analysis we need a conversion factor between the rain data per random-time interval and fixed-time-interval. In this study, the minutely precipitation data on observatory of the Meteorological Administration are used for 37 stations. Therefore, we should conversion factors between the rain data per minute and fixed-time-interval.

  • PDF

인발 방법에 따른 황동관의 변형 해석 (Analysis of Deformation of Brass Tube Drawn By Various Methods)

  • 엄경한
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1995년도 추계학술대회논문집
    • /
    • pp.76-85
    • /
    • 1995
  • The general equation of homogeneous strin for tube drawing has been derived. This can be applied to the general tube drawing method for non-zero plug angle. Also, the derived equation can represent Blazynski's equations for the sinking and tube drawing with a constant plug diameter. The general tube drawing was divided into two steps, sinking and contact drawing zones. The derived equation can calculate the homogeneous strains of the two steps. The various tube drawing methods such as fixed tapered plug, fixed mandrel, fixed back tapered plug, and floating plug have been analysed by the equation and finite element analysis. From the FEM calculations, the total strains and drawing stresses are obtained and consequently the redundancy factor of various drawing methods was analysed. The fixed back tapered plug method showed the largest redundancy factor and the floating plug method had the largest drawing stress.

  • PDF

실험설계 유형별 Venn Diagram을 이용한 EMS 도출 (Derivation of Expected Mean Squares (EMS) Using Venn Diagram by the Type of Experimental Design)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.695-699
    • /
    • 2011
  • The study presents an efficient design method of Venn Diagram that can be used when implementing the quality design of experiments based on generalizability theory. The paper examines four mixed and combined models that are designed by fixed factor, random factor, crossed factor and nested factor. The models considered in this research are $A^*{\times}B^*{\times}C$, (B: $A^*$)${\times}C$, $A{\times}B{\times}C$ and (B: A)${\times}C$.

  • PDF

Declining Fixed Investment and Increasing Financial Investment of Korean Corporations

  • Kim, Daehwan;Kwon, Sunhee;Ryou, Jai-Won
    • East Asian Economic Review
    • /
    • 제23권4호
    • /
    • pp.353-379
    • /
    • 2019
  • This paper aims to determine factors causing the stagnation of Korean firms' fixed investment after the global financial crisis, using panel data for the period of 1999-2016. Fixed investment remained sensitive to cash flow and Tobin's q although their effects decreased after the global financial crisis. A decreasing trend of cash flow and an increase in Tobin's q since the early 2000's imply that the worsening cash flow was a major factor behind the sluggish investment after the crisis. Meanwhile, debt-equity ratio remained significant for non-chaebol affiliated firms, reflecting disparity in access to external financing. Volatility of stock returns also became insignificant after the crisis, casting doubt on the argument that uncertainty was a major factor contributing to the decline of fixed investment. Analysis of financial investment confirmed the significant effect of cash flow, larger than that on financial investment than on fixed investment. In particular, debt repayment and other financial investment, except share repurchase, were sensitive to cash flow. However, the substitution of fixed investment by financial investment is a consequence, rather than a cause of declining fixed investment.

A Novel Zero-Crossing Compensation Scheme for Fixed Off-Time Controlled High Power Factor AC-DC LED Drivers

  • Chang, Changyuan;Sun, Hailong;Zhu, Wenwen;Chen, Yao;Wang, Chenhao
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1661-1668
    • /
    • 2016
  • A fixed off-time controlled high power factor ac-dc LED driver is proposed in this paper, which employs a novel zero-crossing-compensation (ZCC) circuit based on a fixed off-time controlled scheme. Due to the parasitic parameters of the system, the practical waveforms have a dead region. By detecting the zero-crossing boundary, the proposed ZCC circuit compensates the control signal VCOMP within the dead region, and is invalid above this region. With further optimization of the parameters KR and Kτ of the ZCC circuit, the dead zone can be eliminated and lower THD is achieved. Finally, the chip is implemented in HHNEC 0.5μm 5V/40V HVCMOS process, and a prototype circuit, delivering 7~12W of power to several 3-W LED loads, is tested under AC input voltage ranging from 85V to 265V. The test results indicate that the average total harmonic distortion (THD) of the entire system is approximately 10%, with a minimum of 5.5%, and that the power factor is above 0.955, with a maximum of 0.999.

High Throughput 프로세스에서 품질혁신의 성능평가를 위한 Z-Factor의 적용방안 (Implementation of Z-Factor Statistics for Performance Evaluation of Quality Innovation in the High Throughput Process)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.293-301
    • /
    • 2013
  • The purpose of this study is to introduce the limit of previously used six sigma quality process evaluation metrics, $Z_{st}$ and $P_{pk}$, and a solution to overcome this drawback by using a metric based on performance evaluation of Z-factor quality innovation. Case analysis on projects from national six sigma contest from 2011 to 2012 is performed and literature review on new drug development HTS (High Throughput Screening) is used to propose innovative performance evaluation metrics. This research shows that experimental study on six sigma evaluation metric, $Z_{st}$ and $P_{pk}$, have no significance difference between industrial type (Manufacturing, Semi-Public Institute, Public Institute) and CTQ type (Product Technology Type CTQ, Process Technology Type CTQ). Following discovery characterize this quality improvement as fixed target type project. As newly developed moving target type of quality innovation performance metric Z-Factor is used for evaluating experimental study, hypothetical analysis suggests that $Z_{st}$ and $P_{pk}$ share different relationship or even show reciprocal relationship. Constraints of the study are relatively small sample size of only 37 projects from past 2 years and conflict on having interview and communication with six sigma quality practitioner for qualitative experimental study. Both moving target type six sigma innovation project and fixed target type improvement project or quality circle enables efficient ways for a better understanding and quality practitioner use by applying quality innovation performance metric. Downside of fixed target type quality performance evaluation metric, $Z_{st}$ and $P_{pk}$, is presented through experimental study. In contrast, advantage of this study is that high throughput requiring product technology, process technology and quantum leap typed innovation effect is evaluated based on precision and accuracy and Z-Factor that enables relative comparison between enterprises is proposed and implemented.

An SDOF model of a four-sided fixed RC wall having an opening for blast response simulation

  • S.H., Sung;H., Ji
    • Structural Engineering and Mechanics
    • /
    • 제84권5호
    • /
    • pp.675-684
    • /
    • 2022
  • The conventional single-degree-of-freedom (SDOF) system is appropriate for dynamic response analysis of paneltype structures without an opening. However, the typical building structures usually have four-sided fixed walls having an opening. Therefore, it may induce a considerable error when dynamic responses are estimated based on the conventional SDOF system, since the SDOF system cannot consider the effect of an opening during the SDOF analysis. For this reason, this study proposes a new SDOF system to consider the effect of an opening by adjusting its load-mass factor. The load-mass factor can be modified based on the assumption that the behaviors of the four-sided fixed wall with an opening is very similar to the behaviors of the same size wall without an opening, when the uniformly distributed blast loaded area is identical. In order to confirm a feasibility of the proposed SDOF system, a series of numerical simulations were carried out for the four-sided fixed reinforced concrete (RC) wall under a blast load. The dynamic responses estimated from the proposed SDOF system and the conventional SDOF system were compared with the dynamic responses evaluated from the finite element (FE) analysis. Especially, for the maximum dynamic responses except for 50% opening case, the proposed SDOF system had about 1.1% to 25.7% normalized errors while the conventional SDOF system had about 4.1% to 49.1% normalized errors.

Structural redundancy of 3D RC frames under seismic excitations

  • Massumi, Ali;Mohammadi, Ramin
    • Structural Engineering and Mechanics
    • /
    • 제59권1호
    • /
    • pp.15-36
    • /
    • 2016
  • The components of the seismic behavior factor of RC frames are expected to change as structural redundancy increases. Most researches indicate that increasing redundancy is desirable in response to stochastic events such as earthquake loading. The present paper investigated the effect of redundancy on a fixed plan for seismic behavior factor components and the nonlinear behavior of RC frames. The 3D RC moment resistant frames with equal lateral resistance were designed to examine the role of redundancy in earthquake-resistant design and to distinguish it from total overstrength capacity. The seismic behavior factor and dynamic behavior of structures under natural strong ground motions were numerically evaluated as the judging criteria for structural seismic behavior. The results indicate that increasing redundancy alone in a fixed plan cannot be defined as a criterion for improving the structural seismic behavior.

이원혼합모형에서 고정효과 유의성검정에 대한 검정력 분석 (Power analysis of testing fixed effects with two way classification)

  • 이장택
    • 응용통계연구
    • /
    • 제10권1호
    • /
    • pp.177-187
    • /
    • 1997
  • 고정효과가 하나인 이원혼합모형에서의 고정효과 유의성검정에 대한 검정력 분석을 고려한다. 고정효과 수준간의 차이를 검정하는데 사용되는 일반화 최소제곱 F 통계량을 헨더슨의 방법 III, 사전추측값이 1인 MINQUE 추정량, 최우추정법, 제한적 최우 추정법을 이용하여 구하고 이 검정 통계량들의 검정력을 모의실험을 통하여 알아본다. 모의실험의 결과는 결론적으로 검정력의 측면에서 살펴본 효율성은 4가지 추정량 모두 대체적으로 비슷한 것으로 판명되었다.

  • PDF