• Title/Summary/Keyword: Fixed CT

Search Result 134, Processing Time 0.031 seconds

Versatility of n-butyl-2-Cyanoacrylate for the Reconstruction of Frontal Sinus Comminuted Fracture in Children (소아의 전두동에 발생한 복잡골절에서 Cyanoacrylate의 유용성)

  • Lee, Yong-Seok;Kang, Sang-Gue;Chun, Nam-Joo;Kim, Cheol-Hann;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.96-101
    • /
    • 2011
  • Purpose: In treatment of facial bone fracture, occurred in children, we generally use wires, miniplate, absorbable plate or their combination. These foreign bodies can be palpable, and sometimes may cause infections, and need reoperation for removing. When bone fragments are multiple, small or thin, they are hard to handle and make accurate reduction of all fragments. In these cases, a biodegradable tissue adhesive, Histoacryl$^{(R)}$ (n-butyl-2-cyanoacrylate), can be used as fixation technique for small, multiple, and thin fracture fragments. Methods: 3 years old and 6 years old children, who has comminuted fracture on frontal sinus, we used Histoacryl$^{(R)}$ for fixation of multiple bone fragments. After approaching by coronal incision, we pulled out all bone fragments and reconstructed bone fragments by Histoacryl$^{(R)}$ and fixed those on frontal sinus by absorbable plates. Results: Photographs and 3-dimensional CT obtained preoperatively and postoperatively. And we compared them each other in terms of accuracy of reconstructed bony contour. We could reconstruct almost all bone fragments easily along 3-dimensional structure and get excellent aesthetic results. There was no complication such as infection. Conclusion: In treatment of comminuted facial bone fracture, occurred in children, Histoacryl$^{(R)}$ is an excellent method for accurate reconstruction in small and thin bone fragments which cannot be fixed by wire, miniplate or absorbable plate without complication.

Research For Reducing Patient Dose that Low Extremity CT Angiography Using Automatic Current Selection (하지동맥조영 전산화단층촬영에서 자동선량 조절장치를 이용한 환자선량 감소 연구)

  • An, Hyeong-Theck;Kim, Jae-Yeol;Yeo, Woon-Sik;Park, Yong-Sung;Lee, Gui-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • Purpose : Fixed way of mAs previously Low Extremity Computed Tomography Angiography(LECTA) examination were used. Automatic Current Selection(ACS) to use for the purpose of reducing the dose when Low Extremity Computed Tomography Angiography examining patients. Materials and methods : Were analyzed from July 2011 to July 2012 MDCT examination of Dose Length Product(DLP) LECTA 116 Case. It was defined as previous inspection methods(Old protocol). CT workstation is set to 100 mAs and 150 mAs protocol based on the patient's weight 70kg examined by LECTA. We defined as 'New protocol' that applies to ACS. The data collection period are 76 cases from October 2012 to January 2013 Results : 1. Average Total DLP of 'Old protocol' is 3602.943 $mGy^*cm$. 2. Average Total DLP of 'New protocol' is 1762.977 $mGy^*cm$. 3. Due to the 'New Protocol' use of Total DLP was reduced by approximately 51 %. Phase-specific dose reduction is as follows. Pre(33.62 %), Artery(64.63 %), Delay(49.0 %) 4. Using One way ANOVA Analysis of fluctuations obtained DLP is as follows. 'Old protocol', 'New protocol' a value of P < 0.001, P = 0.882 values were obtained. Conclusions : Dose reduction of 51 % is a useful study that proves. The results obtained using the ACS, the effects of a dose reduction of 51 % was obtained. Therefore, it has been proven to be a useful way. Statistics using SPSS version came out of the 'Old protocol' P-value P < 0.0001. This result means that the DLP a large difference values. On the other hand, The results of the 'New protocol' was P = 0.882. These results means to that small and regularly was fluctuations of the dose. The use of ACS, you can get a reduction of the dose and will able to get the effect of reducing the dose errors.

  • PDF

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Prognosis after treatment with multiple dental implants under general anesthesia and sedation in a cerebral palsy patient with mental retardation: A case report

  • Hong, Young-Joon;Dan, Jung-Bae;Kim, Myung-Jin;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • Cerebral palsy is a non-progressive disorder resulting from central nervous system damage caused by multiple factors. Almost all cerebral palsy patients have a movement disorder that makes dental treatment difficult. Oral hygiene management is difficult and the risks for periodontitis, dental caries and loss of multiple teeth are high. Placement of dental implants for multiple missing teeth in cerebral palsy patients needs multiple rounds of general anesthesia, and the prognosis is poor despite the expense. Therefore, making the decision to perform multiple dental implant treatments on cerebral palsy patients is difficult. A 33-year-old female patient with cerebral palsy and mental retardation was scheduled for multiple implant treatments. She underwent computed tomography (CT) under sedation and the operation of nine dental implants under general anesthesia. Implant-supported fixed prosthesis treatment was completed. During follow-up, she had the anterior incisors extracted and underwent the surgery of 3 additional dental implants, completing the prosthetic treatment. Although oral parafunctions existed due to cerebral palsy, no implant failure was observed 9 years after the first implant surgery.

Nonlinear vibration analysis of MSGT boron-nitride micro ribbon based mass sensor using DQEM

  • Mohammadimehr, M.;Monajemi, Ahmad A.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.1029-1062
    • /
    • 2016
  • In this research, the nonlinear free vibration analysis of boron-nitride micro ribbon (BNMR) on the Pasternak elastic foundation under electrical, mechanical and thermal loadings using modified strain gradient theory (MSGT) is studied. Employing the von $K{\acute{a}}rm{\acute{a}}n$ nonlinear geometry theory, the nonlinear equations of motion for the graphene micro ribbon (GMR) using Euler-Bernoulli beam model with considering attached mass and size effects based on Hamilton's principle is obtained. These equations are converted into the nonlinear ordinary differential equations by elimination of the time variable using Kantorovich time-averaging method. To determine nonlinear frequency of GMR under various boundary conditions, and considering mass effect, differential quadrature element method (DQEM) is used. Based on modified strain MSGT, the results of the current model are compared with the obtained results by classical and modified couple stress theories (CT and MCST). Furthermore, the effect of various parameters such as material length scale parameter, attached mass, temperature change, piezoelectric coefficient, two parameters of elastic foundations on the natural frequencies of BNMR is investigated. The results show that for all boundary conditions, by increasing the mass intensity in a fixed position, the linear and nonlinear natural frequency of the GMR reduces. In addition, with increasing of material length scale parameter, the frequency ratio decreases. This results can be used to design and control nano/micro devices and nano electronics to avoid resonance phenomenon.

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

Cuff tear of endotracheal tube induced by a palatal orthodontic device during nasotracheal intubation: a case report

  • Kyung Nam Park;Seung-Hwa Ryoo;Kwang-Suk Seo;Hyun Jeong Kim;Myong-Hwan Karm
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.5
    • /
    • pp.361-366
    • /
    • 2024
  • Orthognathic surgery often requires intraoral orthodontic appliances that are fixed directly to the bone, which can complicate nasotracheal intubation if the devices protrude into the nasal cavity. This case report describes a 19-year-old man scheduled for elective orthognathic surgery who experienced recurrent cuff tears of the endotracheal tube during nasotracheal intubation due to protruding orthodontic screws in the palate. Despite initial attempts at nasotracheal intubation through the left nostril, the cuff of the 7.0 mm internal diameter (ID) Ring, Adair & Elwyn (RAE) tube repeatedly ruptured, with identical rupture patterns observed. Facial CT revealed that the orthodontic screws had protruded into both nasal cavities with significant visibility in the sagittal, coronal, and transverse views. Fiberoptic examination of the left nasal passage identified a firm protrusion below the inferior turbinate, corresponding to the location of the screw, which likely caused the cuff tears. Intubation was successfully performed via the right nostril during the fiberoptic examination. This case highlights the critical importance of evaluating intraoral corrective devices using comprehensive craniofacial imaging before anesthesia induction, as well as conducting fiberoptic examinations during intubation to avoid complications and ensure patient safety.

Implant stability installed with CAD-CAM assisted flapless surgery : A pilot study (CAD-CAM assisted flapless 수술법으로 식립된 임플란트의 안정성 : 기초연구)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Kashiwagi, Kosuke;Kawazoe, Takayoshi;Tanaka, Masahiro
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.405-413
    • /
    • 2011
  • It was proposed that technologies derived from CAD-CAM and computed tomography may be useful for flapless implant treatment procedures. The aims of this study were to validate the reliability of this concept in a prospective 12-month clinical study. Twelve patients with fully edentulous areas in their mandibles were included in this study. A total of 71 implants were inserted in interforaminal regions by use of a CAD/CAM drill template($NobelGuide^{TM}$), specially designed for flapless implant surgery. To assess the degree of pain and discomfort, the patients were examined at 2 days and 1 week after surgery. Patient satisfaction and implant functionality were further evaluated at follow-up intervals of 1, 3, 6, and 12 months postoperatively. One implant failed early in 1 patient. All of the other implants were in a good functional state throughout the study. The mean marginal bone loss after 1 year of follow-up was 0.3 mm (SD, 0.1) at center, 0.5 mm (SD, 0.1) at canine and 0.7 mm (SD, 0.2) at distal fixtures, respectively. Statistically, there was not significant differences among each sites(P>.05)The mean ISQ change after 1 year of follow-up was -1.05 (SD, 2.76) at center, -0.85 (SD, 2.59) at canine and -1.27 (SD, 2.18) at distal fixtures, respectively. This prospective pilot study showed that the use of CAD/CAM technology and flapless implant surgery may be considered reliable for fully edentulous mandible of patients.

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.