• 제목/요약/키워드: Five phase

검색결과 1,094건 처리시간 0.028초

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

Five Clinical Cases of Facial Chuna Manual Therapy with Korean Medicine Treatment for Acute Bell's Palsy

  • Jung Min Son;Hye Soo Youn;Eun Chang Lee;Choong Hyun Park;Sun Woo Kwon;Ji Yoon Lee;Da Young Han;Haeni Seo
    • Journal of Acupuncture Research
    • /
    • 제40권1호
    • /
    • pp.67-77
    • /
    • 2023
  • This study individually analyzed the effects of Korean Facial Chuna Manual Treatment (K-FCMT) combined with Korean medicine (KM) treatment (acupuncture, electroacupuncture, pharmacopuncture, and herbal medicine) on five patients with acute Bell's palsy who visited Dongsuwon Korean Medicine Hospital between August 1 and 31, 2022. During inpatient treatment, two of the five patients received K-FCMT 5-6 times a week, and the other three received the same frequency during outpatient treatment for approximately 2 weeks. Patients with a House-Brackmann grading scale (HBGS) score of ≤4 and Yanagihara unweighted grading system (Y-score) ≥7-8 began to recover after the 2nd-3rd sessions of K-FCMT, which entered the recovery phase quickly. As patients entered the recovery phase (7-9th sessions of K-FCMT), symptoms improved to HBGS scores of 1-2 and Y-scores of 35-40 points. This study suggests the possibility of applying K-FCMT combined with KM treatment to patients in the acute stage of Bell's palsy.

Analysis of Factors Affecting the Periplasmic Production of Recombinant Proteins in Escherichia coli

  • Mergulhao, Filipe J.;Monteiro, Gabriel A.
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권8호
    • /
    • pp.1236-1241
    • /
    • 2007
  • Five fusion proteins between Z domains derived from Staphylococcal Protein A and Green Fluorescent Protein or Human Proinsulin were produced on the periplasm of Escherichia coli. The effects of the molecular weight and amino acid composition of the translocated peptide, culture medium composition, and growth phase of the bacterial culture were analyzed regarding the expression and periplasmic secretion of the recombinant proteins. It was found that secretion was not affected by the size of the translocated peptide (17-42 kDa) and that the highest periplasmic production values were obtained on the exponential phase of growth. Moreover, the highest periplasmic values were obtained in minimal medium, showing the relevance of the culture medium composition on secretion. In silico prediction analysis suggested that with respect to the five proteins used in this study, those that are prone to form ${\alpha}$-helix structures are more translocated to the periplasm.

구체적 피드백과 포괄적 피드백이 건설 현장 근로자들의 안전 행동에 미치는 상대적 효과 검증 (Relative Effects on Construction Workers' Safety Behavior Between Global Feedback and Specific Feedback)

  • 이계훈;오세진
    • 한국안전학회지
    • /
    • 제25권5호
    • /
    • pp.62-68
    • /
    • 2010
  • The main purpose of this study was to examine relative effects on safety behaviors between global feedback and specific feedback at a construction site. Participants were 30 full-time workers at a construction site. Five safety related behaviors were identified as critical behaviors. An ABCB within-group design was adopted. After baseline (A), participants received global feedback on their average percentage of all five target safety behaviors (B). In the next phase, participants received specific feedback on the percentages of individual target behaviors (C). In the final phase, the global feedback condition was reintroduced (B). Results showed that both global feedback and specific feedback were effective in increasing the frequencies of safety behaviors and there were no differences in the effectiveness between the two types of feedbacks.

Hybrid-Boost Modular Multilevel Converter-Based Medium-Voltage Multiphase Induction Motor Drive for Subsea Applications

  • Daoud, Mohamed;Elserougi, Ahmed;Massoud, Ahmed;Bojoi, Radu;Abdel-Khalik, Ayman;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.714-726
    • /
    • 2019
  • This paper proposes a hybrid-boost Modular Multilevel Converter (MMC) for the Medium-Voltage (MV) Variable Speed Drives (VSDs) employed in subsea applications, such as oil and gas recovery. In the presented architecture, a hybrid-boost MMC with a reduced number of semiconductor devices driving a multiphase Induction Machine (IM) is investigated. The stepped output voltage generated by the MMC reduces or eliminates the filtering requirements. Moreover, the boosting capability of the proposed architecture eliminates the need for bulky low-frequency transformers at the converter output terminals. A detailed illustration of the hybrid-boost MMC operation, the expected limitations/constraints, and the voltage balancing technique are presented. A simulation model of the proposed MV hybrid-boost MMC-based five-phase IM drive has been built to investigate the system performance. Finally, a downscaled prototype has been constructed for experimental verification.

Theoretical Studies Gas Phase Reaction of Alkoxide-Exchange at Silicon and Carbon Centers$^\dag$

  • Lee, Ik-Choon;Yang, Ki-Yull;Park, Byong-Seo;Lee, Kae-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권3호
    • /
    • pp.231-235
    • /
    • 1986
  • MNDO and ab initio calculations for gas phase reactions of alkoxide-exchange at silicon and carbon centers have been performed. Results show that MNDO values of ${\Delta}$E's of these reactions closely parallel those of the STO-3G method. The alkoxide-exchange at silicon is shown to be facile due to the formation of stable five-coordinate intermediate while the reaction at carbon is predicted to proceed with high barrier; the difference in this substitution behavior between carbon and silicon is shown to be due to an easy valence shell expansion of silicon in accommodating an extra bond in the formation of stable five-coordinate intermediates.

A Study on a Robust Motion Control of Flexible Manipulator with Five Joint for Untact Working in Filed Work-site

  • Kim, Hee-Jin;Kim, Seong-Il;Jang, Gi-Won;Han, Sung-Hyun
    • 한국산업융합학회 논문집
    • /
    • 제25권2_1호
    • /
    • pp.161-168
    • /
    • 2022
  • This study proposed a new approach to impliment a robusut control of comsumer-friendly flexible manipulator with five joint for untact working in filed work-site. The output redefinition approach was used to overcome the non minimum phase characteristic of the system. The new output is defined so that the zero dynamics related to this output are stable. The control strategy is based on an computed torque method which is applicable to a class of time-invariamt phase linear systems whose uncertainties appear in output loop stable. The controller is composed of a stabilizing joint controller and an output redefinition tracking controller. Experimental results are also presented to verify the effectiveness of the proposed control scheme.

Decoupled SVPWM for Five-Phase Permanent Magnet Machines with Trapezoidal Back-EMF

  • Lin, Zhipeng;Liu, Guohai;Zhao, Wenxiang;Chen, Qian
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1424-1433
    • /
    • 2018
  • This paper presents a novel space vector pulse-width modulation (SVPWM) to synthesize an arbitrary non-sinusoidal phase voltage. The key of the proposed method is that the switching vectors used to comprise the reference vectors in the ${\alpha}_1-{\beta}_1$ frame and the ${\alpha}_3-{\beta}_3$ frame are decoupled. In the ${\alpha}_1-{\beta}_1$ frame, the reference vector is comprised by near two large vectors. The corresponding vector comprised by the two vectors in the ${\alpha}_3-{\beta}_3$ frame is considered as a disturbance, which is restrained by close-loop control. In the ${\alpha}_3-{\beta}_3$ frame, there are two methods to comprise the reference vector. Method I is a near two middle vectors method. Method II uses near four vectors (two middle and two little vectors). The proposed SVPWM using decoupled switching vectors can guarantee a maximum modulation index in the ${\alpha}_1-{\beta}_1$ frame. The effectiveness of the proposed method is verified by simulated and experimental results under various operation conditions.

오행침법효과(五行鍼法效果)의 정량적(定量的) 연구(硏究) (The Quntitative Study of Effects Of O-Haeng Reinforcing-Reducing Manipulation Acupuncture Method)

  • 윤여충;장경선;이해룡
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.211-225
    • /
    • 1998
  • It is very important to understand objectively the Qi variation induced by the reinforcing-reducing manipulation method in the therapy of acupuncture. The Qi variation in the meridian treated by O-Haeng Reinforcing-Reducing Manipulation Acupuncture Method and the recovery of Five Phase deviation were measured by choosing complex acupoints. By using O-Haeng Reinforcing-Reducing Manipulation Acupuncture Method, we increased or decreased the Qi of the phase which caused the unbalance state. We observed whether the Qi of the treated meridian can be increased or not and if the state of unbaIance can be recovered. To achieve the effect of reinforcing-reducing, we need a correct choice of treating method and a selection of a proper meridian in advance. We discovered that the effects of reinforcing-reducing by each manipulation method could be superposed each other, when two counteracting O-Haeng Reinforcing-Reducing Manipulation Acupuncture Method were treated at the left and the right side of human body. We found that the Qi variation of the traeted meridian, which was induced by O-Haeng Reinforcing-Reducing Manipulation Acupuncture Method, is lineary proportioned to the reduction of Five Phase deviation.

  • PDF

혼종 모형을 이용한 간호 학습전이의 개념 분석 (A Concept Analysis on Learning Transfer in Nursing Using the Hybrid Model)

  • 손해경;김효진;김동희
    • 한국직업건강간호학회지
    • /
    • 제29권4호
    • /
    • pp.354-362
    • /
    • 2020
  • Purpose: This study aimed to define and clarify learning transfer in nursing. Methods: This study used a hybrid model to analyze the concept of learning transfer in nursing through three phases. For the theoretical phase, learning transfer attributes were identified through a scoping literature review. In the fieldwork phase, in-depth focus group interviews were conducted to develop attributes. Purposive sampling was performed with ten participants(five nursing students, two nurses, three nursing faculty members). In the analysis phase, the attributes and final analysis of learning transfer in nursing were extracted and integrated from the previous two phases. Results: According to the analysis, learning transfer was represented in two dimensions with eight attributes. The development of competency dimension had three attributes: 1) theory acquisition, nursing skills, professional attitude, 2) integration, and 3) analysis competency. The competency change dimension had five attributes: 1) appropriateness in patient care, 2) proficiency in patient care, 3) satisfaction, 4) achievement, and 5) confidence. Conclusion: The concept analysis might provide a basic understanding of learning transfer, a development framework toward a measurement of nursing learning transfer and effective educational nursing strategies.