• 제목/요약/키워드: Fittings

검색결과 180건 처리시간 0.022초

일체형 삽입식 신속 연결구를 이용한 건축 배관 연결 공법의 시공성 및 경제성 분석 (An Analysis of Constructability and Economic Efficiency for Pipe Work using Insert & Coupling Joint Method)

  • 김태훈;김대원;석성준;박철;이준서;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.189-194
    • /
    • 2006
  • The internal construction industry is not situation of cost reduction based on low wages anymore by the increase in wages as insufficient supply of stilled workers. Recently remodeling constructions that only need to change facilities as to stay the existing structures are on the increase. Now the method of piping facility used to remodeling construction needs stilled workers, large work space and a variety of tools. These complex construction process have a difficulty of high-quality and economical construction. In addition it have the hish incidence of warranty and a problem of cost increase as a commitment of manpower by warranty repair. In order to solve these problems it is necessary for appropriate new technology to the internal construction environment. Piping fittings by Insert & Coupling Joint is a method that unskilled workers can be easily constructed though one touch set up and it is convenient to maintain for repair work of piping facility. This technology show the effect of 3 percentages labor cost reduction as compared with piping fittings by press joint on apartment 500 households. Therefore this technology is supposed that attain a cost reduction though the technical and economical construction and a client satisfaction though the high-quality construction on the present construction market.

  • PDF

오리피스 유량계에서 게이지라인 누설에 의한 계량오차 (The Measurement Error owing to Leakage of Gaugeline in Orifice Flowmeter)

  • 이철구;하영철;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.143-148
    • /
    • 2003
  • This study was experimentally performed in order to estimate the errors due to the leakage of transmitter gaugelines in the orifice flow meter for natural gas. It would be a serious problem in safety if a large quantity of leak was occurred at the tubes or fittings like valve. But in most cases the safety problems might be rarely happened because the gas leak detectors could be operated in advance and the various kinds of inspection would be also fulfilled periodically. If the leakage was occurred continuously with an undetectable amount at the gaugelines for measuring the pressure or the differential pressure(DP), the amount of leakage might be an error or an unaccounted flow(UAE). In addition if the measuring value of pressure or DP were affected by the leakage, it might also be a measurement error. The experiments were performed to estimate the amount of leakage and to check the DP changes if it exited. First, through the measurement of the air pressure changes in the airtight container connected to a transmitter with gaugelines as the time passed, the amount of leakage causing from the fittings of gaugelines was roughly estimated. As changing the leak position of the gaugeline, the leak was intentionally made to break out. The variance of DP was checked as controlling the extent of leakage and compared to no leak conditions. Consequently, under the normal maintenance conditions, the result represented that the amount of leakage causing from the gaugelines was insignificant and also the DP changes on leakage conditions were too small to cause the errors of measurements.

  • PDF

폴리머 애자의 End-fitting 설계 및 성능 평가기술 (End-fitting Design and Performance Evaluation of Polymer Insulator)

  • 조한구;이운용;한세원;한동희;지원영;여학규;강두원;천종욱;이형규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.25-29
    • /
    • 2004
  • Corona on polymer materials causes deterioration by the combined action of the discharge striking the surface and the action of certain chemical compounds that are formed by the discharges. In the design and manufacture of polymer insulators must be sufficiently large to avoid corona discharges, otherwise a shielding or corona ring (grading ring) needs to be installed on the insulator. To conduct this purpose, many researchers have investigated end-fitting of polymer insulator by voltage distribution simulation and electrical test. Grading rings are used to improve the performance of the insulator in multiple ways. They can reduce corona and associated audible noise and radio influence and television interference. The factors determining the uses of a grading ring are line voltage, geometry and dimensions of end fittings, geometry and dimensions of line hardware, and environmental conditions. In this paper, electrical property of polymer insulator with end-fitting design have been investigated by electrical field analysis, various end-fitting design, tracking wheel test, corona inception voltage and extinction voltage. Electrical field analysis is conducted by FEM program and various end-fitting is designed through this result. Designed end-fittings are manufactured and their performance is conducted by electrical performance test.

  • PDF

V련 현수애자장치의 클램프 횡진 특성 (A Characteristics of Horizontal Swing Angle of Suspension Clamp in V type Suspension String Sets)

  • 손홍관;이형권;민병욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권3호
    • /
    • pp.133-138
    • /
    • 2005
  • This paper presents a characteristics of horizontal swing angle in V type suspension string sets for 765kV T/L. The design of V type suspension string set does not differ from that of general string set for general towers, but it prevents instabilities from swing motion by the horizontal angle and by the wind pressure. We were designed specially 6 conductor yoke, arcing horn and earth horn. And we were decided to 550mm for a distance of strings. We were carried out characteristics of horizontal swing test and movement of mass center test for V-string sets of 400kN single, 300kN double and 400kN double. This products will be used for 765kV T/L of 1 circuit in suspension towers.

Thermoforming Technology of Textile Composite Tubes

  • OZAKI Jun-ichi;MANABE Ken-ichi
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 The Korea-Japan Plastics Processing Joint Seminar
    • /
    • pp.63-66
    • /
    • 2003
  • Thermoforming of fiber reinforced thermoplastic (FRTP) braided tubes was studied as a new forming technique. FRTP braided tubes with four plies are fabricated by the pressure bonding method are used in thermoforming. Bulge forming, bending process, pipe fittings and FE analysis are carried out in this study. In bulge forming the composite tube can be expanded up to about two times initial diameter. The suggested bending process can be obtained bent products with various bending radii. In pipe fitting it is possible to fabricate T-shape fitting, cross fitting and two-branch fitting. These results exhibit developed forming processes become useful processes for textile composite tubes.

  • PDF

전력케이블 고장원인 분석에 관한 사례연구 (A Case Study on the Failure Cause Analysis of Power Cables)

  • 황광수;최종수;정종욱;정진수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.345-347
    • /
    • 2007
  • 본 논문에서는 전력케이블 및 그 부속설비에 대한 사고원인을 분석한 사례를 서술하였다. 사고원인을 정밀하게 분석하기 위해서 케이블 외관의 육안검사 단계부터 케이블 해체 단계까지 전기적 검사 및 화학적 검사를 실시하였다. 분석결과, 전력케이블은 시공방법을 준수하지 않아서 수축튜브의 마감부위에 전계가 집중되어 가압 이후 지속적인 부분방전이 발생하여 케이블에 누적된 스트레스로 인해 발생한 고장으로 추정되었다.

  • PDF

AWWA C304를 적용한 PCC관 설계 및 Fitting 설계 전산프로그램 (PCCP Desing Program using AWWA C304 and Fitting Design Program)

  • 김영수;김두영;조능호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.815-822
    • /
    • 1999
  • This program is developed to design Prestressed Concrete Cylinder Pipes (PCCP), Fittings and Thurst Blocks and to manage drawings, quantity calculations and calculation data, using Graphic User Interface(GUI), which is capble of not only reducing the time taken to design, but also enabling the user to achieve such a design even when operator has no theoretical knowledge of that design while only having knowledge of data inputting and outputting. PCCP is used in water transmission popeline of the Great Man-made River Project. In domestic area, PCCP is used for water cooling systems of Uljin and Youngkwang nuclear power. In abroad, especially in the United States and Canada PCCP applies virtually every metropolitan area with raw and treated water.

  • PDF

IMPACT OF THE LOW SOLAR ABUNDANCE ON THE AGES OF GLOBULAR CLUSTERS

  • Yi, Su-Kyoung K.;Kim, Yong-Cheol
    • 천문학회지
    • /
    • 제43권4호
    • /
    • pp.135-139
    • /
    • 2010
  • We present the result of our investigation on the impact of the low Solar abundance of Asplund and collaborators (2004) on the derived ages for the oldest star clusters based on isochrone fittings. We have constructed new stellar models and corresponding isochrones using this new solar mixture with a proper Solar calibration. We have found that the use of the Asplund et al. (2004) metallicity causes the typical ages for old globular clusters in the Milky Way to be increased roughly by 10%. Although this may appear small, it has a significant impact on the interpretation for the formation epoch of Milky Way globular clusters. The Asplund et al. (2004) abundance may not necessarily threaten the current concordance cosmology but would suggest that Milky Way globular clusters formed before the reionization epoch and before the main galaxy body starts to build up. This is in contrast to the current understanding on the galaxy formation.

전방압출과 연계된 레이디얼압출의 성형특성에 관한 연구 (A Study on the Forming Characteristics of Radial Extrusions Combined with Forward Extrusion)

  • 장용석;황병복
    • 소성∙가공
    • /
    • 제9권3호
    • /
    • pp.242-248
    • /
    • 2000
  • This paper is concerned with the family of parts that generally feature a central hub with radial protrusions. Radial Extrusion is usually used in order to produce complex parts, which is combined with upsetting and/or forward and backward extrusion. Typical parts that fall into this category include cross pieces for universal joints, key-shaft type parts, tube fittings, and differential gears. In this paper, the forming characteristics of radial extrusion combined with forward extrusion is investigated by comparing the punch and mandrel loads. The design factors during radial extrusion combined with forward extrusion are applied to the simulation to see how much those factors have effect on the forming loads. The rigid-plastic FEM is applied to the simulation.

  • PDF

밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가 (Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting)

  • 강승규;이원식;윤준용;민경화
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.29-37
    • /
    • 2003
  • This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.