• 제목/요약/키워드: Fittings

검색결과 180건 처리시간 0.034초

배관 형상이 다회선 초음파 유량계의 특성에 미치는 영향 (Installation effects on the characteristics of multi-path ultrasonic flowmeter)

  • 박경암;최용문;최해만;윤병로;황규보
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.114-117
    • /
    • 1999
  • Five-path ultrasonic flowmeters (200 and 300 mm diameters) were tested to obtain it's characteristics in a water flow standard system. A five-path ultrasonic flowmeter was installed after various pipe fittings (elbow, valve, tee) or a pump. The distance between flow disturbance source and a flowmeter was main experimental parameter. Without a flow conditioner, a five-path ultrasonic flowmeter shows good characteristics as the distance between flow disturbance source and a flowmeter is longer than 10 diameter of a flowmeter.

  • PDF

용접부의 형상과 공정변화에 따른 소구경 분기배관의 피로강도 특성평가 (S-N Fatigue Strength of Small Diameter Branch Welded Pipe with Variation of Welding Shapes and Welding Procedures)

  • 백종현;김우식
    • Journal of Welding and Joining
    • /
    • 제22권3호
    • /
    • pp.50-55
    • /
    • 2004
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 m and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

A Special Pre-Service-Inspection Using Radiographic Testing(RT) for Brazing Fitting Uused in Aircraft Hydraulic System

  • Kim, Gyu-Ho
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.271-281
    • /
    • 2010
  • Brazing fitting which is one of the aircraft hydraulic power system components is widely used for saving weight and achieving higher reliability. Any inherent defects or damage of fitting can cause system failure and/or physical damage of human body due to highly pressurized fluid. Radiographic testing(RT) technique and additional micro-structure investigation on cut-away surfaces have been accomplished to find out some defect-like-inhomogeneity in the fittings. The radiography results showed that some defect-like-inhomogeneity existed inside body. Additional micro-structure investigation on cut-away surface reveals that the inhomogeneity is due to internal voids. In this study, it can be is said that RT technique can be a useful tool for field acceptance test of hydraulic brazing fitting in short time.

복합 덕트시스템의 유량분배에 관한 1차원 해석의 적합성 (Adaptability of one-dimensional analysis for the flow distribution of a complex duct system)

  • 이승철;이재헌
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.579-587
    • /
    • 1999
  • The flow distribution characteristics in a complex duct system have been investigated in this paper by three means, namely experimental measurement, numerical simulation and the Extended T-method analysis. While the exit flow rates predicted by the three-dimensional CFD calculation and those given by the experiment show a close agreement, the results from the one-dimensional Extended T-method are found to differ from the experiment by -22.2% to 26.3% for the various exits. These discrepancies may be attributed to the underlying limitation concerning the fitting loss coefficients, which assume that the flow in front of the fittings is fully developed. It is proposed that, in order to analyse the three-dimensional flow distributions in a complex duct system by one-dimensional analysis such as the Extended T-method, further Improvements to the fitting loss coefficients should be made.

  • PDF

SUS 육각봉 인발성형 시스템의 클램프 가이드 바에 관한 구조해석 (Structural Analysis on Clamp Guide Bar of Drawing Process System for SUS Hexagonal Bar)

  • 이영식;양영준
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.796-802
    • /
    • 2018
  • In order to remove rust and impurities from surface of raw SUS circular bar, peeling machine is used to make lustrous and clean surface of SUS circular bar. Drawing process system is used to manufacture SUS hexagonal bar. SUS hexagonal bar have been widely used to make hexagonal bolt/nut, adapter and fittings and so on. The purpose of this study is to investigate the stabilities for guide bar of clamp in drawing process system. As the results, the guide bar showed structural stability in cases of below load of 50 Ton and over hook radius of 3.0mm. Further as the thickness of guide bar hooking with jaw was increased, minimum safety factor was decreased.

원전 증기발생기 감육 급수링 응력해석 (A Stress Analysis of Wall-Thinned Feedwater Ring in Nuclear Power Plant)

  • 조민기;조기현
    • 한국압력기기공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.56-63
    • /
    • 2021
  • The feedwater ring is an assembly in steam generator internal piping, which distributes feedwater into the secondary side of the steam generator. It consists of an assembly of carbon steel piping, pipe fittings and J-nozzles which are inserted into the top of the feedwater ring and welded to the diameter of the ring. The feedwater ring at the attachment region of the J-nozzle may be susceptible to flow accelerated corrosion (FAC) due to flow turbulence which increases local fluid velocities. If a J-nozzle becomes a loose part, it can cause damage to tubing near the tube sheet. In this paper, the structural stress analysis for a wall thinned feedwater ring and integrity evaluations under assumed loading conditions are carried out in compliance with ASME B&PV SecIII, NB-3200.

BVI PHOTOMETRIC STUDY OF THE OLD OPEN CLUSTER RUPRECHT 6

  • Kim, Sang Chul;Kyeong, Jaemann;Park, Hong Soo;Han, Ilseung;Lee, Joon Hyeop;Moon, Dae-Sik;Lee, Youngdae;Kim, Seongjae
    • 천문학회지
    • /
    • 제50권3호
    • /
    • pp.79-92
    • /
    • 2017
  • We present a BV I optical photometric study of the old open cluster Ruprecht 6 using the data obtained with the SMARTS 1.0 m telescope at the CTIO, Chile. Its color-magnitude diagrams show the clear existence of the main-sequence stars, whose turn-off point is located around $V{\approx}18.45mag$ and $B-V{\approx}0.85mag$. Three red clump (RC) stars are identified at V = 16.00 mag, I = 14.41 mag and B - V = 1.35 mag. From the mean $K_s-band$ magnitude of RC stars ($K_s=12.39{\pm}0.21mag$) in Ruprecht 6 from 2MASS photometry and the known absolute magnitudes of the RC stars ($M_{K_S}=-1.595{\pm}0.025mag$), we obtain the distance modulus to Ruprecht 6 of $(m-M)_0=13.84{\pm}0.21mag$ ($d=5.86{\pm}0.60kpc$). From the ($J-K_s$) and (B - V ) colors of the RC stars, comparison of the (B - V ) and (V - I) colors of the bright stars in Ruprecht 6 with those of the intrinsic colors of dwarf and giant stars, and the PARSEC isochrone fittings, we derive the reddening values of E(B - V ) = 0.42 mag and E(V - I) = 0.60 mag. Using the PARSEC isochrone fittings onto the color-magnitude diagrams, we estimate the age and metallicity to be: $log(t)=9.50{\pm}0.10(t=3.16{\pm}0.82Gyr)$ and $[Fe/H]=-0.42{\pm}0.04dex$. We present the Galactocentric radial metallicity gradient analysis for old (age > 1 Gyr) open clusters of the Dias et al. catalog, which likely follow a single relation of $[Fe/H]=(-0.034{\pm}0.007)R_{GC}+(0.190{\pm}0.080)$ (rms = 0.201) for the whole radial range or a dual relation of $[Fe/H]=(-0.077{\pm}0.017)R_{GC}+(0.609{\pm}0.161)$ (rms = 0.152) and constant ([Fe/H] ~ -0.3 dex) value, inside and outside of RGC ~ 12 kpc, respectively. The metallicity and Galactocentric radius ($13.28{\pm}0.54kpc$) of Ruprecht 6 obtained in this study seem to be consistent with both of the relations.

상수도관내 중금속 용출에 대한 수소이온농도의 영향 평가 연구 (Influences of pH on Heavy Metal Leaching in Water Supply Pipelines)

  • 이정원;노유래;박준홍
    • 대한토목학회논문집
    • /
    • 제37권1호
    • /
    • pp.73-82
    • /
    • 2017
  • 우리나라 상수도 기반시설 설비에 관련된 기존의 인증평가는 경제적 측면과 내구성 등 물리적 측면에 초점을 맞추어 사용되어 왔다. 그러나 경제수준이 상승하면서 상수도에 대한 위생, 보건, 안전성, 삶의 질에 대한 국민의식이 향상됨에 따라 상수도 서비스의 위생보건학적 품질향상이 요구되고 있다. 지난 5년간 국내 497개 정수장의 수질분석 자료를 고찰한 결과 pH는 5.8~8.5의 범위로 나타났다. 하지만, 현재 우리나라 수도용 자재 및 제품의 위생안전기준 공정시험방법(위생안전시험법)은 pH 7.0에서만 평가하고 있어, 실제 상수도 pH 조건에서 관내 중금속용출에 대한 기초정보가 부족하다. 이러한 배경으로 본 연구에서는 국내에서 대표적으로 사용되는 관에 대하여 pH변화가 중금속용출에 미치는 영향을 실험적으로 분석연구하였다. 본 연구 결과, pH가 낮아질수록 일부 금속의 용출정도가 증가하는 것을 확인하였다. 특히 pH 5.8일 경우, 구리재질의 관에서 Cu가 보정계수(Normalization Factor) 적용 후에도 위생안전기준을 상회하였다. 스테인레스 재질의 관에서는 Cr, Cu가, 구리재질의 이음관에서는 Cd, Pb, Cu, Zn이, 아연재질의 이음관에서는 Zn이 기준치를 각각 상회하였으나 보정계수를 적용하면 기준치를 만족하였다. 본 연구의 결과로 현행 위생안전시험법에서 pH조건을 7.0 이외의 낮은 pH 조건을 포함하는 개정의 필요성이 제안되었다. 추후 상수도관으로 사용되는 다른 종류의 관에 대한 추가 연구의 필요성도 제시되었다. 본 연구는 차후 우리나라 위생안전기준의 개정연구에 필요한 기초자료 제시에 기여를 하였다.

Nutrient Leaching from Leaf Litter of Emergent Macrophyte(Zizania latifolia) and the Effects of Water Temperature on the Leaching Process

  • Park, Sangkyu;Cho, Kang-Hyun
    • Animal cells and systems
    • /
    • 제7권4호
    • /
    • pp.289-294
    • /
    • 2003
  • To quantify nutrient loading from emergent macrophytes through leaching in the littoral zones of Paldang Reservoir, we conducted incubation experiments using leaf litter of the emergent macrophyte, Zizaniz latifolia. To separate the leaching process from microbial decay, we used $HgCl_2$ to suppress microbial activity during the experiment. We measured electric conductivity, absorbance at 280nm, total nitrogen and dissolved inorganic nitrogen, total phosphorus and soluble reactive phosphorus, Na, K, Mg and Ca amounts in leaf litter and in water. In addition, we examined the effects of water temperature and ion concentrations of ambient water on the leaching process. A total of 6% of the initial ash-free dry mass of leaf litter was lost due to leaching during incubation (four days). Electric conductivity and A280 continued to increase and saturate during the incubation. To compare reaching rates of different nutrients, we fitted leaching dynamics with a hyperbolic saturation function [Y=AㆍX/(B+X)]. From these fittings, we found that ratios of leaching amounts to nutrient concentration in the litter were in the order of K > Na > Mg > P > Ca > N. Leaching from leaf litter of Z. latifolia was dependent on water temperature while it was not related with ion concentrations in the ambient water. Our results suggest that the leaching process of nutrients, especially phosphorus, from aquatic macrophytes provides considerable contribution to the eutrophication of the Paldang Reservoir ecosystem.

Property Changes of Woven Blouse Fabrics by bonding fusible interlinings for a 3D Virtual Try-on System

  • Kim, Myoung-Ok;Park, Myung-Ja
    • 한국의류산업학회지
    • /
    • 제16권6호
    • /
    • pp.1008-1016
    • /
    • 2014
  • This study aims to analyze the changes in the mechanical properties of woven fabrics(cotton, linen, wool, silk, and polyester) by bonding fusible interlinings with varying deniers(10D, 20D, and 30D) for a 3D virtual try-on system(one that a user to try garments through screens using Avatar) developed over the last decade. We experimented with four mechanical properties and thicknesses of twenty-three specimens of interlining bonded fabrics including face fabrics and interlinings by using the KES-FB-AUTO system. The results showed that the tensile property increased(LT and RT increased and WT decreased) as the denier of the interlining increased; however, the change was slight. In contrast, the bending and shear properties increased significantly as the denier of the interlining increased on both the warp and the weft. This showed evidence that the interlining gives the fabrics size stability. The compression property was slight changed as the tensile property varies depending on the fibers and the denier of interlining. As expected, the thickness increased by bonding the interlining as the denier of interlining increased. From these results, we conclude that 3D users need to reflect these changes of woven fabrics by bonding interlinings when they try screen fittings to accurately express the fabric reality of manufactured garment.