• Title/Summary/Keyword: Fitting Model

Search Result 1,330, Processing Time 0.032 seconds

XPD Analysis on the Cleaved GaAs(110) Surface (절개된 GaAs(110) 면의 XPD 분석)

  • Lee, Deok-Hyeong;Jeong, Jae-Gwan;O, Se-Jeong
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.171-180
    • /
    • 1993
  • X-ray photoelectron diffraction (XPD) is used to characterize the crystallographically cleaved GaAs(110) surface. By using polar and azimuthal scans of the usual angle-resolved x-ray photoelectron spectroscopy, we get the reconstruction geometry of the clean GaAs(110) surface from the intensity ratio of Ga 3d core-level peaks. The reconstruction parameters are determined by fitting the diffraction pattern with the single scattering cluster (SSC) model, and the results show similar tendencies to those obtained by other techniques.

  • PDF

PWF-GPH method for the statistical analysis of failure time data (고장시간 자료의 통계적 분석을 위한 PWF-GPH 방법)

  • 김선영;윤복식
    • Journal of the military operations research society of Korea
    • /
    • v.22 no.1
    • /
    • pp.114-128
    • /
    • 1996
  • In this paper, a life distribution fitting method based on generalized phase-type distributions(GPH) is presented. By fitting the life distribution to a GPH, we can utilize various useful properties of the GPH. Two different approaches are used according to the properties of the given failure time data. One is an approximation to a GPH through the piecewise Weibull failure rate(PWF) model and the other is a direct approximation to a GPH using the empirical distribution function. Two numerical examples are also presented. In the first example, both of the two approaches are utilized and compared for an incomplete data set. And in the second example, the direct approximation method from an empirical distribution is utilized for the analysis of a complete data set. In both cases, we could confirm the validity of the proposed method.

  • PDF

Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies (전자기 과도 현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가)

  • Wang, Yong-P.;Hur, Dong-Y.;Park, Hee-C.;Chung, Hyeng-H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.252-255
    • /
    • 2001
  • Modern power systems are very complex and to model them completly is impractical for electromgnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing FDNE is presented and demonstrated. The FDNE is generated by Linearized Least Square fitting the frequency response of a z-domain formulation. The advantage of this approach is that a direct implementation occurs which dose not incur errors due to discretization inherent with implementing a fitting function in the s-domain. The developed FDNE is accurate and efficient.

  • PDF

Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases (룰 베이스를 이용한 공조기의 고장검출 및 진단)

  • 한도영;주명재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

A Current Compensation Algorithm for a CT Saturation (CT 포화 복원 알고리즘)

  • Yi, Xiao-Li;Kang, Sang-Hee;Lee, Dong-Gyu;Kang, Yong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.88-90
    • /
    • 2003
  • In this paper, an algorithm to compensate the distorted signals due to CT(Current Transformer) saturation is suggested. Firstly, WT(Wavelet Transform) is used to detect a start point and an end point of saturation. Filter banks which can be easily realized in real-time applications are employed in detecting CT saturation. Secondly, least-square curve fitting method is used to restore the distorted section of the secondary current. Fault simulations are performed on a power system model using EMTP(Electromagnetic Transient Program). A series of test results indicate that WT has superior detection accuracy and the proposed algorithm which shows very stable features under various levels of remanent flux is also satisfactory.

  • PDF

Frequency Dependend Network Equivalents to Electromagnetic Transient Simulation (주파수 의존 등가회로의 전자기 과도 현상 시뮬레이션)

  • Wang, Y.P.;Jo, K.S.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.592-593
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand.

  • PDF

Approximate Analysis of the Discrete-time 2-Node Tandem Queueing Network with a Correlated Batch Input Traffic (상관적인 Batch 입력을 갖는 2-노드 Tandem 구조의 이산시간 대기 네트워크의 근사적 분석)

  • Park, Du-Yeong
    • The Journal of Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1997
  • We first describe an approximation method for fitting a k-state MMBP to the departure process of a D-BMAP/Geo/1/K queue. The fitting model is them used in a simple decomposition algorithm to analyze a tandem configuration of finite capacity queue with cell loss.

  • PDF

Wind tunnel tests on wind loads acting on steel tubular transmission towers under skewed wind

  • YANG, Fengli;NIU, Huawei
    • Wind and Structures
    • /
    • v.35 no.2
    • /
    • pp.93-108
    • /
    • 2022
  • Steel tubular towers are commonly used in UHV and long crossing transmission lines. By considering effects of the model scale, the solidity ratio and the ratio of the mean width to the mean height, wind tunnel tests under different wind speeds on twenty tubular steel tower body models and twenty-six tubular steel cross-arm models were completed. Drag coefficients and shielding factors of the experimental tower body models and cross-arm models in wind directional axis for typical skewed angles were obtained. The influence of the lift forces on the skewed wind load factors of tubular steel tower bodies was evaluated. The skewed wind load factors, the wind load distribution factors in transversal and longitudinal direction were calculated for the tubular tower body models and cross-arm models, respectively. Fitting expressions for the skewed wind load factors of tubular steel bodies and cross-arms were determined through nonlinear fitting analysis. Parameters for skewed wind loads determined by wind tunnel tests were compared with the regulations in applicable standards. Suggestions on the drag coefficients, the skewed wind load factors and the wind load distribution factors were proposed for tubular steel transmission towers.

Analysis of Bending and Rotation Phenomenon of Torsion Bar During Press-fitting Process for EPS Angle Sensors (EPS 각도센서용 토션 바의 압입공정의 휨과 회전현상 분석)

  • H. Lee;S.H. Lee;T.H. Jeon;I.-K. Chung
    • Transactions of Materials Processing
    • /
    • v.32 no.6
    • /
    • pp.376-383
    • /
    • 2023
  • The torsion bar, which is a steering torque sensor, is mounted between the steering pinion and the input shaft in the IPA(input pinion assembly). Accurate torque measurement is important to improve the sense of operation, and the straightness of the torsion bar can affect torque measurement. In this study, the amount of bending was measured and the exact shape was analyzed regarding the bending phenomenon in the press-fitting process for torsion bars. The effect of alignment error was analyzed through finite element forming analysis. Process data analysis was conducted for the double-end press fit model. If there is an alignment error of about 10% of the serration tooth height, the indentation load is reduced by about 10%. If there is an alignment error, the torsion bar is rotated.