• Title/Summary/Keyword: Fitness System

Search Result 624, Processing Time 0.025 seconds

The changing of fitness and exercise guidelines for old adults (노인들의 체력 변화와 운동의 제언)

  • Yoon, Byung-Kon
    • Journal of Life Science
    • /
    • v.17 no.6 s.86
    • /
    • pp.867-872
    • /
    • 2007
  • The aging is related to numerous changes in our body system which declines functional ability. The functional ability in advanced age can be evaluated by the 4 components of fitness (cardiorespiratory endurance, muscular strength and endurance, flexibility and body composition). The understanding and knowledge of changing 4 components of fitness and the role of exercise on the process of aging is of paramount importance. Despite exercise and physical activity have been shown to delay the process of aging, the exercise guidelines and recommendations for old adults are not well published. This review is to presents the age-related changes in each component of fitness and to present current guidelines and recommendations for exercise in older adults.

Fitness Sharing Particle Swarm Optimization Approach to FACTS Installation for Transmission System Loadability Enhancement

  • Chang, Ya-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • Proper installation of Flexible AC Transmission Systems (FACTS) devices in existing transmission networks can enable power systems to accommodate more power transfer with less network expansion cost. The problem to maximize transmission system loadability by determining optimal locations and settings for installations of two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). For solving the MDCP, in the paper, the proposed method with fitness sharing technique involved in the updating process of the particle swarm optimization (PSO) algorithm, can diversify the particles over the search regions as much as possible, making it possible to achieve the optimal solution with a big probability. The modified IEEE-14 bus network and a practical power system are used to validate the proposed method.

Problems and Development of Police Officials' Physical Fitness Tests (경찰공무원 체력검정의 문제점 및 발전방안)

  • Kim, Sang-Woon
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.609-619
    • /
    • 2019
  • The study aims to present a solution to the problem of police physical fitness tests as police officers, who tried to subdue the drunk in a video clip titled "Darim-dong female police officer Assault" in May in Seoul, showed a rather lethargic figure, such as being pushed out of a physical fight with the suspect. The police physical fitness test is subject to criticism as it consists of items that are difficult to apply in real life despite having to be linked to job performance. The problem is that the physical fitness test events are not realistic, the physical fitness test standards are set too low, and their credibility is not reliable due to the imbalance of standards between men and women and the vision culture of physical fitness testing methods. First of all, we hope that the Republic of Korea will become a world-class security powerhouse by upgrading its physical fitness standards and establishing a scientific fitness test system for preventing injuries and effectively measuring physical strength.

The Study on the Impact of the Task-Technology Fit Model and Organizational Characteristics of the Mobile Office System on the Job Performance (모바일오피스의 과업·기술 적합모델과 조직특성이 직무성과에 미치는 영향에 관한 연구)

  • Koo, Sung-Hwan;Shin, Min-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.644-654
    • /
    • 2013
  • It is required for enterprises to construct the proper information management system in order to cope with the volatile business situations. The mobile office system is introduced from the needs to provide organization members smart information and mobility. By setting the model, hence, we intend to scrutinize the impact of the task-technology fit model and organizational characteristics of the mobile office system on the job performance. As a result, system quality, information quality and mobility are revealed to affect positively the task-technology fitness and the fitness also affects the job performance positively. Organization characteristics affects the job performance positively through the task-technology fitness, too. Therefore the organization which plans to introduce the mobile office system should consider the task-technology fitness and exert organizational-level efforts to adopt and use the mobile office system in the workplace.

A comparison of marginal fitness by dental alloys (치관 보철물 제작에 사용되는 치과용 금속의 변연 적합도 비교)

  • Kim, Nam-Joong;Hwang, Kyung-Sook;Park, Yong-Duk
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.29-40
    • /
    • 2003
  • This study was aimed to verify a comparison by dental alloys upon the marginal fitness of dental prosthesis. Firstly, we waxed up on 45 epoxy resin dies, pressed the margin with hands, and identified the marginal fitness with microscope. And we made a single direct spruing system type of sprue by 3 dental alloys - metal crown alloys, PFM crown alloys, and gold crown alloys - each 15, total 45 waxing up, adjusting W/P ratio and invested the cast ring. Then, we made the dental prosthesis using the electric casting machine. In these processes we followed the manufacturer's instructions, in order to maintain the other conditions from the inner and outer, which included investment and burning out. After we tried on the dental prosthesis on epoxy resin dies, we have got the means of marginal gap at 9 points with same distances, around the cervical line which was checked already, using microscope($\times$300). The results of this study were as follows : 1. Metal crown alloys showed 2.9% better in marginal fitness than PFM crown alloys, and the difference was not statistically significant(P=0.497). 2. Gold crown alloys showed 31.3% better in marginal fitness than Metal crown alloys, and the difference was statistically significant(P=0.004). 3. Gold crown alloys showed 32.4% better in marginal fitness than PFM crown alloys, and the difference was statistically significant(P=0.002). 4. We saw that Gold crown alloys was the best dental alloys in the marginal fitness among the three.(P=0.049).

  • PDF

Effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings (석고 모형재와 고무인상재의 젖음성이 지르코니아 코핑의 변연적합도에 미치는 영향)

  • Kim, Won-Young;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.255-262
    • /
    • 2016
  • Purpose: This study examined the effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings. Methods: Three commercially available gypsum materials(Fugirock EP, Snow Rock, Tuff Rock) and three zirconia blocks(iJAM Emerald, LUXEN Smile block, ICE Zirkon transluzent) were studied. The zirconia copings were fabricated by using dental CAD/CAM system. Contact angles on the impression materials were measured with contact angle measuring device. Silicone replica method was used to measure the marginal fitness and cutting was performed on the bucco-lingual and mesio-distal sides. It were observed with a stereomicroscope at °ø40 magnification. The data were statistically analyzed with One-way ANOVA. Results: Mean values of contact angles were $58.3{\pm}0.7^{\circ}$ for Tuff Rock, $77.5{\pm}0.5^{\circ}$ for Fugirock EP and $87.8{\pm}0.5^{\circ}$ for Snow Rock and the difference between them was statistically significant(p<0.05). The smallest values of marginal fitness for the JF groups were $30.7{\pm}3.0{\mu}m$ for bucco-lingual direction, $29.3{\pm}3.0{\mu}m$ for mesio-distal direction. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). Conclusion: Tuff rock gypsum material had superior wettability to others. The mean marginal fitness of the Tuff rock gypsum material group were significantly better than other groups. Thus they can be also expected to show clinically satisfactory marginal fitness.

Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer

  • Kang, Wol;Kim, Min-Su;Kim, Won-Gi
    • Journal of dental hygiene science
    • /
    • v.19 no.4
    • /
    • pp.238-244
    • /
    • 2019
  • Background: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high precision and relatively low cost. Therefore, the latest trend in resin crown manufacturing is the use of DLP 3D printers. However, studies on the internal fitness of such resin crowns are insufficient. The recently introduced 3D evaluation method makes it possible to visually evaluate the error of the desired area. The purpose of this study is to evaluate the internal fitness of resin crowns fabricated a by DLP 3D printer using the 3D evaluation method. Methods: The working model was chosen as the maxillary molar implant model. A total of 20 resin crowns were manufactured by dividing these into two groups. One group was manufactured by subtractive manufacturing system (PMMA), while the other group was manufactured by additive manufacturing system, which uses a DLP 3D printer. Resin crowns data were measured using a 3D evaluation program. Internal fitness was calculated by root mean square (RMS). The RMS was calculated using the Geomagic Verify software, and the mean and standard deviation (SD) were measured. For statistical analysis, IBM SPSS Statistics for Windows ver. 22.0 (IBM Corp., USA) was used. Then, independent t-test was performed between the two groups. Results: The mean±SD of the RMS were 41.51±1.51 and 43.09±2.32 for PMMA and DLP, respectively. There was no statistically significant difference between PMMA and DLP. Conclusion: Evaluation of internal fitness of the resin crown made using a DLP 3D printer and subtractive manufacturing system showed no statistically significant differences, and clinically acceptable results were obtained.

Mechanical Property and Process Variables Optimization of Tube-to-Tube Friction Welding for Steel Pipe with 36 mm External Diameter (외경 36mm 강관의 관대관 마찰용접 특성과 공정 변수 최적화)

  • Kong, Yu-Sik;Park, Young Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Friction welding is a very useful joining process to weld metals which have axially symmetric cross section. In this paper, for the friction welding with tube-to-tube shape, the feasibility of industry application was determined using analyzing mechanical properties of weld and optimized welding variables was suggested. In order to accomplish this object, rotating speed, friction heating pressure, and friction heating time were selected as the major process variables and the experiment was performed in three levels of each parameter. Weld characteristic was investigated in terms of weld shape and metal loss, and 7mm of metal loss was regarded as the optimal metal loss. By tensile test, tensile strength and yielding strength was measured and fracture was occurred at base metal. In order to optimize the welding condition, fitness function was defined with respect to metal loss and yielding strength and the fitness values for each welding condition could be calculated in experimental range. Consequently, we set the optimal welding condition as the point which had maximum value of fitness function. As the result of this paper the optimal welding variables could be suggested as rotating speed was 1300 rpm, friction heating pressure was 15 MPa, and friction heating time was 10 sec.

The Effects of Fitness Between Centralization of IT Activities and Organizational Strategy on Information System Performance. (정보기술 활동의 집중화와 조직 전략간의 적합도가 정보시스템 성과에 미치는 영향에 관한 연구)

  • 한경일
    • The Journal of Information Technology
    • /
    • v.2 no.1
    • /
    • pp.131-147
    • /
    • 1999
  • According to literature review, fitness between IT activities and organizational strategy enhances performance. Theoretical research says that centralized company in IT activities is appropriate to cost-leadership strategy and decentralized company in IT activities is appropriate to differentiation strategy. But there are very few empirical research. The purpose of this study is to attest whether fitness between IT activities and organizational strategy enhances the information system performance. But the results of this field study were not consistent with literature that fitness of two independent variables enhance performance. So we should take other contingency variables such as organizational structure, culture etc. into consideration to investigate relationship between IT activities and strategy.

  • PDF

A New Fitness Index for Simulated Implantation System of Artificial Hip Joint based on 3D Medical Images (3차원 의료영상에 기반한 인공고관절 모의시술 시스템 개발 및 새로운 정합도 측정 방법에 관한 연구)

  • 김용호;김중규;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.201-212
    • /
    • 2000
  • 본 논문에서는 인공고관절과 환자의 고관절 부위를 각각 3차원 영상화한 후에 이들의 정합도 (fitness)를 측정하여 수치적인 정보로 제공함으로써 환자의 체형에 적합한 인공고관절을 선택하고, 더 나아가 정확한 시술방향과 시술깊이를 제공할 수 있는 모의시술시스템을 제시하였다. 이를 위해 region growing 기법등을 이용하여 환자의 CT 영상을 3차원화하고, 또한 인공고관절을 projection 기법 등을 통해 3차원 영상화하였으며, 지금까지 인공고관절 정합도 측정에 사용했던 단순한 단면적 비교방식과는 달리 삽입의 균일성도 가늠할 수 있는 새로운 정합도 측정 방식을 고안하여 적용하였다. 다양한 실험과 분석을 통하여 새로 제안한 정합도 측정 방법의 정확성과 우수함을 확인할 수 있었으며, 본 논문에서 제시하는 모의 시술시스템은 향후 정형외과 분야에서 인공무릎과 같은 다른 영역에서의 시술 보조 시스템으로도 응용될 수 있을 뿐만 아니라, 인공관절의 국산화 및 주문제작 등에성도 많은 활용을 할 수 있을 것으로 기대된다.

  • PDF