• 제목/요약/키워드: Fit accuracy

검색결과 323건 처리시간 0.021초

냉간단조품의 정밀도향상을 위한 금형해석 기법 (Methodology of tool analysis to improve the accuracy of cold forged parts)

  • Kim, T.H.;Kim, B.M.;Park, J.C.
    • 한국정밀공학회지
    • /
    • 제12권1호
    • /
    • pp.29-37
    • /
    • 1995
  • In many metal forming processes, it is common to use stress rings for reducing elastic deformation and failures of forming dies. But, shrink fit of dies inner diameter of die insert, machining is reuqired after shrink fit processes. The reduction of inner diameter can be predicted by the analysis of elastic-plastic finite element method. The dimension of dies before shrink fit can be determined to minimize or remove machining after shrink fit processes by deformation analysis of die. The computation of contacting stresses along die surface was analyzied by rigid plasitic finite element method, and data were interpolated by the contact search algorithm. In this paper, we propose the analysis method of forging dies after shrink fit and forming to improve dimensional accuracy of final products.

  • PDF

Accuracy of Data-Model Fit Using Growing Levels of Invariance Models

  • Almaleki, Deyab A.
    • International Journal of Computer Science & Network Security
    • /
    • 제21권12호
    • /
    • pp.157-164
    • /
    • 2021
  • The aim of this study is to provide empirical evaluation of the accuracy of data-model fit using growing levels of invariance models. Overall model accuracy of factor solutions was evaluated by the examination of the order for testing three levels of measurement invariance (MIV) starting with configural invariance (model 0). Model testing was evaluated by the Chi-square difference test (∆𝛘2) between two groups, and root mean square error of approximation (RMSEA), comparative fit index (CFI), and Tucker-Lewis index (TLI) were used to evaluate the all-model fits. Factorial invariance result revealed that stability of the models was varying over increasing levels of measurement as a function of variable-to-factor ratio (VTF), subject-to-variable ratio (STV), and their interactions. There were invariant factor loadings and invariant intercepts among the groups indicating that measurement invariance was achieved. For VTF ratio (3:1, 6:1, and 9:1), the models started to show accuracy over levels of measurement when STV ratio was 6:1. Yet, the frequency of stability models over 1000 replications increased (from 69% to 89%) as STV ratio increased. The models showed more accuracy at or above 39:1 STV.

Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도 (IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM)

  • 김봉철;이채은;박원서;강정완;이충국;이상휘
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권5호
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

의복관련 맞음새 평가에 관한 연구동향 - 2000~2016년 국내학회지를 중심으로 - (Trend of Studies on the Evaluation of Clothing Fit - Focusing on Domestic Research Journals of 2000~2016year -)

  • 이진희;김윤희
    • 한국의상디자인학회지
    • /
    • 제18권4호
    • /
    • pp.159-170
    • /
    • 2016
  • This study is aimed to research the trend of studies on the evaluation of clothing fit using the domestic research journals. clothing fit has long been regarded as the most important element to customers in clothing appearance. Understanding fit from a consumer's perspective is complex. 85 articles were collected from domestic academic sites (KISS, DBpia, KiSTi). Many clothing fit articles published on the 2011-2016 year. In research target, young women were more than other age groups. On the evaluation of clothing fit, method of clothing fit classified survey using the questionnaire and wearing test. Many articles were used the survey using the questionnaire, 57.7%. The other articles were used wearing test with professional analyst and objective evaluation tool. Objective evaluation was used 3D virtual wearing systems (i-designer, DC suit, CLO et al). In the survey using the questionnaire and wearing test using the objective evaluation, jacket and pants were researched on the clothing items mainly. Many young women put on the jacket and pants to active energetically. In the future, researches related clothing fit need to develop the objective and accuracy evaluation tool of clothing fit.

  • PDF

수치지도 좌표계 전환에 관한 연구 (Development of Coordinate Transformation Tool for Existing Digital Map)

  • 윤홍식;조재명;송동섭;김명호;조흥묵
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.373-378
    • /
    • 2003
  • This study deals with development of transformation tool for transformation of digital map coordinates systems using by the best fit transformation parameters which are determined between the local geodetic datum and geocentric datum (ITRF2000) in Korea and distortion modelling derived from collocation method. We used 107 control points as a common points. For analyzing the derived parameters, another 83 common points are tested. Finally, the best fit parameters are determined from Molodensky-Badekas model after considering the RMSE, maximum value, minimum values, and 95% confidence interval of residuals. after transformation of best fit parameters and distortion modelling, we could develop transformation tools with advenced accuracy. so it is possible to perform on transformation of digital map with scale 1:5,000. and we tested accuracy eveluation through analysis between transformation results and field results of GPS observation.

  • PDF

크로스핏 파워 트레이닝이 TPI OnBaseU Power Test와 골프 수행력에 미치는 영향 (Effect of CrossFit Power Training on TPI OnBaseU Power Test and Golf Performance)

  • Chang Wook Kim
    • 한국운동역학회지
    • /
    • 제33권4호
    • /
    • pp.185-195
    • /
    • 2023
  • Objective: The purpose of this study is to improve TPI OnBaseU Power Test and golf performance by conducting CrossFit power training. Method: Three male golf players from University B participated in this study. They had 3 to 4 years of golf experience and participated in 8 weeks of CrossFit power training. Results: OnBaseU Power Test: There was a lot of improvement in Sit up throw (27.9%) and Chest pass (10.58%), but there was not much improvement in Baseline Toss (R5.9, L9.8%) and Vertical Jump (4.1%). Golf shot data: There was a very statistically significant difference in Club speed, Ball speed, and Total Length, which are related to speed, and there was no difference in Club path and Smash factor, which are related to accuracy and posture. Conclusion: CrossFit power training was effective in improving TPI OnBaseU Power Test and golf performance (Club speed, Ball speed, Total Length).

유방자가검진 교육이 자가검진 행위에 미치는 영향 (The Effects of Education on Breast Self-Examination Practices)

  • 최경옥;서연옥
    • 대한간호학회지
    • /
    • 제28권3호
    • /
    • pp.718-728
    • /
    • 1998
  • Breast self-examination is the most effective and easiest way for women to increase the responsible consciousness about their health. The purpose of this study was to test the variables impacted to promote breast self-examination practice. The research design used in this study was a nonequevalent control group of a non-synchronized design. The sample that was assembled consisted of 124 women. A purposive sample consisted of 124 women. Each subject was given to assessed on the following the demographic data related to the breast self-examination, knowledge of self-examination, accuracy, in performing self-examination, self-efficacy about breast cancer and breast self-examination, and the number of subjects who found a mass. The result of this study may be summarized as follows : 1. To examine the theretical model fit to the data, chi square test statistics and goodness of fit index were identified($\chi$$^2$=2.30, df=2, GFI=0.99, AGFI=0.94 RMSR=0.02, NFI=0.99, NNFI=0.99, Critical Number=439). 2. The direct effects of education of breast self-examination were knowledge, self-efficacy, accuracy, number finding a mass. But the Indirect effect of education on breast self-examination was frequency of breast self-examination. 3. Knowlege, as direct paths to the breast self-examination practices, was removed in the theoretical model. The parsimonious best fit model included self-efficacy, accuracy, the number finding mass, frequency of breast self-examination practices. 4. The final model produced a chi-square=5.58(p=0.35) with df=5, and GFI =0.99, AGFI =0.94, RMSR=0.03, NFI=0.99, NNFI=0.99, CN=339 indicating very a good fit. Based on the result of this study, education of breast self-examination is very effective for increasing the competency of the breast self-examination through the knowledge and self-efficacy. Resources to promote self-efficacy may be helpful to increase the frequency of self-examination because self-efficacy is a direct effect on it. These findings suggest the need to develop nursing strategy to promote the self-efficacy of breast self-examination.

  • PDF

형상기억합금을 이용한 열박음 공구홀더 개발 (Development of Shrink-Fit Tool Holder using Shape Memory Alloys)

  • 신우철;노승국;김병섭;박종권
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.889-894
    • /
    • 2010
  • Conventional shrink-fit tool holders have positive features, such as high accuracy, high strength, high stiffness and low sensitivity to centrifugal forces, but they require heavy investments for heating and cooling equipment. Generally the heating equipment has to heat the tool holder up to $200{\sim}300^{\circ}C$ for tool changes. This paper introduces a novel shrink-fit tool holder that is able to unclamp a tool at $40{\sim}50^{\circ}C$. This feature makes it possible to switch between the clamped and unclamped states by using a simple device, which has lower power, smaller size and lower cost than the heating equipment of the conventional shrink-fit tool holders. The proposed shrink-fit tool holder is able to expand its tool hole by using the shape memory alloys which are integrated in the tool holder body. Performances of the SMA shrink-fit tool holder were evaluated experimentally. The experimental results confirm that the proposed tool holder is feasible in aspects of clamping/unclamping operations, clamping force and repeatability of tool setup.

디지털 치과모형의 정확도 평가 방법에 대한 고찰 (A review on the accuracy assessment methods of 3-dimensional digital dental models)

  • 박지수;임영준;이정원;김봉주
    • 구강회복응용과학지
    • /
    • 제35권2호
    • /
    • pp.55-63
    • /
    • 2019
  • 본 논문은 기존에 선행되었던 연구들을 바탕으로 디지털 모형의 정확도를 평가하는 여러 가지 방법에 관하여 정리하였다. 디지털 모형의 정확도 평가 시, 시험자 교육과 인공적 지표의 사용을 통해 오차를 줄일 수 있다. 디지털 치아 모형의 정확도 평가법은 크게 선형 측정법, 2차원 단면 분석법, 3차원 최적합 분석법으로 분류할 수 있다. 스캐너의 기술이 발전함에 따라 디지털 인상 기술과 전통적 인상법의 정확도를 비교하는 많은 연구들이 이루어지고 있다. 다양한 방법을 이용하여 디지털 모형의 정확도를 평가할 수 있으며, 앞으로 스캐너의 기술 향상 및 3차원 모형 분석 소프트웨어의 개발에 따라 디지털 모형의 정확도 평가 방법이 더욱 효과적으로 변화할 것이라 생각된다. 이 논문에서는 디지털 모형의 정확도를 평가하는 방법들에 대해 소개하고, 각각의 상황에 따른 효과적인 정확도 분석법에 대해 알아보고자 한다.