• Title/Summary/Keyword: First insulating oil

검색결과 7건 처리시간 0.02초

습도를 고려한 절연유 시험 결과의 보정 방안 연구 (Correction Measures That Take Humidity into Account in Insulating Oil Test Measurement Results)

  • 김완수;노재필;강석구
    • 한국전기전자재료학회논문지
    • /
    • 제37권5호
    • /
    • pp.541-546
    • /
    • 2024
  • Climate conditions, especially transport and storage, are a very important factor in the process of sampling and testing insulation oil in the field. The samples of insulating oil exposed to the atmosphere affect the dielectric strength, total acid number and moisture test value by oxygen and high humidity environment and may also affect the results according to the criteria specified in each test. Therefore, reliable test values for insulating oil testing require consideration of the atmospheric environment of the test site, including oxygen and humidity. In this paper, each test was conducted on insulating oil exposed to various time and humidity environments, and the effect of the atmospheric environment on the test results was analyzed by comparing and analyzing with the first insulating oil.

배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석 (Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers)

  • 안정식;최순호;방정주;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

전계가 가해진 절연유의 유동대전 특성 고찰 (Study on the Streaming Electrification of Insulating oil Under Electricfield)

  • 허창수;정중일
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권4호
    • /
    • pp.334-341
    • /
    • 1997
  • Streaming electrification on insulating paper and pressboard under D.C. and A.C. electric field was investigated by using paper tubes and oil circulation apparatus. At first, flowing of static charges as measured with no electric field. As the temperature of oil increased, the measured current curve hows peak. As the velocity increased, it shows increasing exponential curve. Then, we applied A.C. and D.C. electric field on paper tube and the current from relaxation tank to earth was measured, which other factors such as temperature and velocity were varied like case of no electric field. The ions in oil carry the charges. So electric field makes asymmetry effect, and electrophoretic effect on ions in oil. We find that as the electric field intensity increased, the charges which were made by electric double layer were increased. The charge vs. velocity curve made peak point at a velocity.

  • PDF

광섬유 센서를 이용한 부분방전 측정연구 (A Study on Partial Discharge Measurement using Optical Fiber Sensors)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

가교폴리에틸렌 계면에서의 트리성장 분석 (An Analysis of Tree Growth in the XLPE Interface)

  • 김철운;박현빈;김태성;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.90-94
    • /
    • 1998
  • This study aims at analyzing to treeing in the solid-solid interface which is insulation type of cable junction parts, the proceeding of tree-growth and electrical breakdown were research in the study. Interface was made artificially to detect how it influenced the insulating ability of the whole system, the specimen were XLPE generally used in cable. The interface conditions were divided into two parts. First condition being the one focused on the surface of interface, it was treated with sand paper (#80, #600, #1200). For the second condition, the pressure of interface was varied as the value of 1, 5, 10 [$kg/cm^2$]. Using above conditions, treeing and breakdown properties on tree-growth were respectively compared in details. As a result, breakdown time was shorter for the full range of supplied voltage in the case of interface existed in the joint than non-existed interface. In the case of existed interface, the interface which had high-interface pressure and painted with silicon insulating oil was the best in the aspect of breakdown characteristics.

  • PDF

절연재료 수명평가용 프로그램 개발 (Development of the Program for Estimation Lifetime of Insulating Materials)

  • 박성민;배덕권;이성일;오재한;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.46-49
    • /
    • 2000
  • This paper studied development of the program for estimation the life time of insullating materials and the longtime breakdown voltage. First, short-time breakdown voltage of Epoxy and insulating oil was measured. Life exponent was gained from measurement of insulating breakdown time of the specimens. Life time is presumed from program. The estimation program is based on the "Inverse Power Law", defined $V^nt$ is constant. After gaining the life exponent n, it is mapping the longtime breakdown voltages. On the base of life exponent, the estimation the lifetime and usefulness of the insulation systems are possible, furthermore easy calculation is possible.

  • PDF

The Investigation on Thermal Aging Characteristics of Oil-Paper Insulation in Bushing

  • Liao, Rui-jin;Hu, En-de;Yang, Li-jun;Xu, Zuo-ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1114-1123
    • /
    • 2015
  • Bushing is the key link to connect outer and inner insulating systems and also the essential electric accessory in electric power system, especially in the high voltage engineering (AC 1000kV, DC 800kV). This paper presented the experimental research of thermal aging characteristic of oil-paper insulation used in bushing. A thermally accelerated aging experiment at 90℃ was performed. The bushing models containing five layers of paper were sealed into the aging vessels and further aged for 250 days. Then several important parameters associated with the aging were observed and evaluated. The results showed that the degree of polymerization (DP) of papers gradually decreased. The DP values of outermost layer and middle layer fit well into the second-order kinematic model and first-order kinematic model, respectively. Less deterioration speed of the inter-layer paper than outer layer was confirmed by the variation of DP. Hydrolysis was considered as the main cause to this phenomenon. In addition, the logarithm of the furfural concentrations in insulation oil was found to have good linear relationship with DP of papers. Interestingly, when the aging time is about 250 days and DP is 419, the aging process reaches an inflection point at which the DP approaches the leveling off degree of polymerization (LODP) value. Both tanδ and acid number of oils increased, while surface and volume resistivity of papers decreased. The obtained results demonstrated that thermal aging and moisture absorbed in papers brought great influence to the degradation of insulating paper, leading to rapid decrease of DP and increase of the tanδ. Thus, the bushing should be avoided from damp and real-time monitoring to the variation of tanδ and DP values of paper is an effective way to evaluate the insulation status of bushing.