• 제목/요약/키워드: First Heat

검색결과 2,002건 처리시간 0.021초

한우 인공수정에서 수정적기 진단키트 활용이 수태율에 미치는 영향 (Effects of Optimal Heat Detection Kit on Fertility after Artificial Insemination (AI) in Hanwoo (Korean Native cattle))

  • 최선호;진현주
    • 한국수정란이식학회지
    • /
    • 제32권3호
    • /
    • pp.153-157
    • /
    • 2017
  • This study was conducted to investigate the optimal artificial insemination (AI) time with diagnostic kit at ovulation time. We already applied the patent about the protein in the cow heat mucose in external reproductive tract. And we would examine the accuracy for detection of cow heat by the kit produced with the protein. Evaluation of optimal heat detection was tried two time at 12 hrs and 24 hrs after the heat. And then, AI service also performed two times with no relation to the results of heat diagnosis by heat detection kit and pregnancy rates were checked with rectal palpation on $60^{th}$ day after AI. Heat diagnostic results by kit in natural heat after 12 hrs in Hanwoo cows were showed 31.3~75.0% on positive in first heat detection and 33.3~100.0% on positve in second heat detection. In the $1^{st}$ positive results were significant different (p<0.05), but $2^{nd}$ positive were not. The results of heat detection showed different result on regional influence and individual cow effects. The pregnancy rates of first trial of heat detection were showed 34.4~78.7% on positive and 21.3~68.8% on negative after the diagnosis by heat detection kit. And the pregnancy rates of next trial of heat detection were showed 33.3~85.7% on positive and 14.3~66.6% on negative after the heat diagnosis. Both positive results of first trial and next trial also were showed significant different (p<0.05), but negative results were not. In positive result, first trial of total pregnancy rates was higher than the next trial of pregnancy, but there showed opposite results on negative results. In conclusion, the optimal heat detection kit is suitable to ordinary Hanwoo cows and it suggested that we have to improve the kit's accuracy by detecting the materials like proteins related optimal AI time.

High heat flux limits of the fusion reactor water-cooled first wall

  • Zacha, Pavel;Entler, Slavomir
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1251-1260
    • /
    • 2019
  • The water-cooled WCLL blanket is one of the possible candidates for the blanket of the fusion power reactors. The plasma-facing first wall manufactured from the reduced-activation ferritic-martensitic steel Eurofer97 will be cooled with water at a typical pressurized water reactor (PWR) conditions. According to new estimates, the first wall will be exposed to peak heat fluxes up to $7MW/m^2$ while the maximum operated temperature of Eurofer97 is set to $550^{\circ}C$. The performed analysis shows the capability of the designed flat first wall concept to remove heat flux without exceeding the maximum Eurofer97 operating temperature only up to $0.75MW/m^2$. Several heat transfer enhancement methods (turbulator promoters), structural modifications, and variations of parameters were analysed. The effects of particular modifications on the wall temperature were evaluated using thermo-hydraulic three-dimensional numerical simulation. The analysis shows the negligible effect of the turbulators. By the combination of the proposed modifications, the permitted heat flux was increased up to $1.69MW/m^2$ only. The results indicate the necessity of the re-evaluation of the existing first wall concepts.

열처리에 따른 복합레진 인레이의 굴곡강도에 관한 연구 (A STUDY ON FLEXURAL STRENGTH OF COMPOSITE RESIN INLAY ACCORDING TO HEAT TREATMENT)

  • 김용성;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.84-94
    • /
    • 1993
  • The purpose of this study was to evaluate flexure strength of composite resin inlay according to heat treatment and duration in comparasion with visible light-cured resin. In this study, materials were used 1 visible light-cured resin and 3 kinds of composite resin inlays. Control group was visible light cured resin (Photo Clearfil Posterior) and experimental groups were composite resin inlays (Brilliant Dentin, Brilliant Enamel and Clearfil CR Inlay). Experimental groups were divided 3 groups: First group was Brilliant Dentin and second group was Brilliant Enamel and -third group was Clearfil CR Inlay. Used experimental groups were calculated flexural strength according to heat treatment and duration. The following results were obtained: 1. Experimental groups were higher flexural strength than control group. 2. At $100^{\circ}C$ when heat treatment carried out 7 minutes flexural strength elevated third group, second group, first group in turn and when heat treatment carried out 15 minutes flexural strength elevated third group, second group, first group in turn but no difference was showed between first and second group. 3. At $125^{\circ}C$ when heat treatment was carried out 7 minutes flexural strength elevated third group, second group, first group in turn and when heat treatment was carried out 15 minutes flexural strength elevated third group, first group, second group in turn but no difference was showed between first and second group. 4. In spite of heat treatment and duration the third group was highest flexural strength in the others groups.

  • PDF

150 RT급 흡수식 열펌프용 고온재생기의 열전달 특성 (The heat transfer characteristics of a desorber for 150 RT absorption heat pump)

  • 박찬우;정종수
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.369-376
    • /
    • 1999
  • Experiments were carried out to study the heat transfer characteristics of a disrober for 150 RT LiBr-water absorption heat pump. An experimental apparatus was divided into four sections, a combustion chamber area, two bare-tube areas, and finally a finned-tube area to quantify the heat transfer rate of each section by measuring the generation rate of vapor. Dividing plates was installed at the upper inside part of deserter to prohibit the moving of vapor generated at heating tubes of a section to another section near. In the first bare-tube area, the generation rate of vapor was the largest among the four sections. The finned-tube area only contributed to give sensible heat increase of solution to the saturation temperature. The heat transfer area of the finned-tube area was 52.2%, which absorbed only 9.2% of the total heat from the combustion gas. On the contrary, the heat transfer area of the first bare-tube area was 16.6%, but it absorbed 52.4% of the total absorbed heat. The temperature of the solution at upper part at the finned-tube area was lower than that of the lower part, because weak solution came in upper part of the finned-tube area. But, this tendency was changed at the first and second bare-tube area due to the vigorous heat transfer and fluid flow enhanced by vapor generation through heating tubes. The overall heat transfer coefficient and heat flux were the largest at the first bare-tube area among the other sections.

  • PDF

ICE GROSS HEAT RELEASE STRONGLY INFLUENCED BY SPECIFIC HEAT RATIO VALVES

  • Lanzafame, R.;Messina, M.
    • International Journal of Automotive Technology
    • /
    • 제4권3호
    • /
    • pp.125-133
    • /
    • 2003
  • Several models for the evaluation of Gross Heat Release from the internel combustion engine (ICE) are often used in literature. One of these is the First Law - Single Zone Model (FL-SZM), derived from the First Law of Thermodynamic. This model present a twice advantage: first it describes with accuracy the physic of the phenomenon (charge heat release during the combustion stroke and heat exchange between gas and cylinder wall); second it hat a great simplicity in the mathematical formulation. The evaluation of Heat Release with the FL-SZM is based on pressure experimental measurements inside the cylinder, and ell the assumption of several parameters as the specific heat ratio, wall temperature, polytropic exponent for the motored cycle evaluation, and many others. In this paper the influence of gases thermodynamic properties on Cross Heat Release has been esteemed. In particular the influence of an appropriate equation for k=k(T) (specific heat ratio vs. temperature) which describes the variations of gases thermodynamic properties with the mean temperature inside the cylinder has been evaluated. This equation has been calculated by new V order Logarithmic Polynomials (VoLP), fitting experimental gases properties through the least square methods.

Assessment of the performances of a heat exchanger in a light helicopter

  • Carozza, Antonio
    • Advances in aircraft and spacecraft science
    • /
    • 제2권4호
    • /
    • pp.469-482
    • /
    • 2015
  • This study has the aim to develop a numerical design regarding the position and the inner performances of a heat exchanger in a light helicopter. the problem was to find first of all the best position of the heat exchanger inside the engine vane in order to maximize the air flow rate capable to pass through the heat exchanger section. It is to be said that the only air contribution in the vane comes from the opening present in the roof under the main rotor. The design has been performed by means of the commercial code Fluent and using the well known grid generator ICEM CFD. Different positions are first investigated so to establish the best one. Subsequently, different areas of the opening on the roof have been considered in order to maximize even more the flow rate in the heat exchanger that was not sufficient based on the first guess of velocity, as aforementioned. At the end interesting design results are presented and discussed by contours of fields and values.

Dairy Potential of Pabna Cows and Crossbreds with Sahiwal and Friesian and Within- and Between-Breed Sire Effects

  • Hoque, M.A.;Amin, M.R.;Hussen, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권2호
    • /
    • pp.161-164
    • /
    • 1999
  • Dairy performances of Pabna cows and its crossbreds with Sahiwal (SL) and Friesian (F) in the Baghabarighat dairying area of Bangladesh were evaluated. Four SL and three F sires were used for the crossbreeding. The exotic sire effect of individuals on their daughters were also evaluated in this study. It showed that the genetic group had a significant (p<0.05) effect on birth weight, age at first heat, calving interval, lactation length and lactation yield. The lowest birth weight (17.9 kg), longest age at first heat (39.2 m) and calving interval (16.3 m) shortest lactation length (199 d) and lowest lactation yield (728 L) were found in Pabna cows. The highest birth weight (22.5 kg). shortest age at first heat (25.5 m) and calving interval (13.7 m), longest lactation length (253 d) and highest lactation yield (1936 L) were found in the F crossbreds. Within the same breed, the effect of individual sire was significant (p<0.05) on age at first heat, lactation length and lactation yield. Individual sire effects of SL bulls differed significantly (p<0.05) but F sires had a non-significant (p>0.05) effect on calving interval in their progeny. The fat % and SNF % in milk and number of services required for conception did not differ (p>0.05) among inter-and intra- breed sire groups.

제1종 LiBr-H2O 흡수식 열펌프의 시뮬레이션 (Simulation of the First Kind LiBr-H2O Absorption Heat Pump)

  • 허준영;최영돈
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.11-26
    • /
    • 1990
  • The first kind LiBr -$H_2O$ absorption heat pump system was simulated and the performances of it were predicted. The elements of heat pump system, evaporator, absorber and generator were analysed by solving the energy balance equations and concentration equations which describe the reactions between working fluids. The results show that the temperature gain of absorber and condenser and the COP of the system are affected considerably by the operating conditions of heat pump system.

  • PDF

태음인(太陰人) 표열증(表熱證) 설사(泄瀉)에 대한 고찰 (A Research on Exterior Heat Syndrome Diarrhea of Taeumin(太陰人))

  • 신상원
    • 대한한의학원전학회지
    • /
    • 제31권2호
    • /
    • pp.155-172
    • /
    • 2018
  • Objectives : The first object is to reveal the mechanism of diarrhea based on exterior heat syndrome for Taeumin as explained in Donguisusebowon's Taeeumingansuyeoliyeolbyeonglon. The second objective is to review the treatment for Taeumin as explained in Leejema's Galgeunnabogjatang because the drug composition of Galgeunnabogjatang, the drug that treats this syndrome, is not written. Methods : As the first step, the paper will review the disease pathology for Taeumin written, and check the existence of disease path that can be viewed as exterior heat syndrome. As the second step, the paper will review the probability of exterior heat syndrome deriving from Taeumin disease path and morph into the exterior heat syndrome. Results : Using the first step to discover the direct correlation between exterior heat syndrome and the theory of disease for Taeumin led to a failure, but through the second step, the paper was able to confirm the probability that exterior heat syndrome could derive from Wiwansuhanpyohanbyeong's Wiwanhanjeung. Based on this, the paper was able to determine the Galgeunnabogjatang suitable for the treatment of exterior heat syndrome. Conclusions : Exterior heat syndrome is created when healthy qi is stimulated to quickly build up the pathogen of Taeumin exterior heat syndrome, but only exterior heat is generated and the cold remains. Its main symptoms are fever, excessive sweating, and difficult painful red-urination. Exterior heat syndrome diarrhea refers to the diarrhea which is generated from the Taeumin's disease pathology. The paper determined that Galgeunnabogjatang, which is listed in Donguisusebowon the seventh edition Boyubang.

마이크로핀관 응축기 내 냉매-냉동기유 혼합물의 전열 특성 (Condensation heat transfer for refrigerant-oil mixtures in microfin tube condenser)

  • 조금남;태상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.90-95
    • /
    • 2000
  • Condensation heat transfer experiments for R-22 and R-407C refrigerants mixed with mineral oil and POE oil respectively were performed in straight and U-bend sections of a microfin tube. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400 kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and inlet quality increased. The heat transfer coefficients in the U-bend were the maximum at the $90^{\circ}$ position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficients at the first straight section.

  • PDF