• 제목/요약/키워드: Firing Control System

검색결과 157건 처리시간 0.023초

가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계 (A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System)

  • 김재곤;허욱열;김병륜
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권11호
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

3상 전류평형 제어기술 알고리즘 개발 (A Development of 3 Phase Current Balance Control Algorithm)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

계통연계 풍력발전 시스템의 최대출력 제어를 위한 PI 제어기의 성능 분석 (Performance of PI Controller for Maximum Power Extraction of a Grid-Connected Wind Energy Conversion System)

  • 노경수;류행수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.391-397
    • /
    • 2002
  • This paper presents a modeling and simulation of a PI controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm fnr a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the Pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

Tabu Search를 이용한 TCSC의 점호각 제어용 퍼지 제어기의 설계 (Design of Fuzzy Controller for Firing Angle of TCSC Using Tabu Search)

  • 김우근;황기현;문경준;김형수;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.37-39
    • /
    • 2000
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on Power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small of large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC. we performed the computer simulation for single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows the better control performance than PD controller.

  • PDF

과도 안정도 향상을 위한 TCSC의 점호각 제어용 퍼지제어기의 설계에 Tabu 탐색법의 적용 (Application of Tabu Search in Design of Fuzzy Controller for Firing Angle of TCSC Improving Transient Stability)

  • 김우근;황기현;김형수;박준호;박중근
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.561-567
    • /
    • 2001
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small or large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC, we performed the computer simulation fur single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows better control performance than PD controller.

  • PDF

전류형 HVDC 시스템의 최적 운전각 결정 (Determination of Optimal Operating Angle for HVDC System)

  • 김진영;김재한;김찬기
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.7-15
    • /
    • 2012
  • In this paper a process of determination for thyristors operating with optimal angle is described. The proposed method is based on the trade-off between the cost(due to rating and loss) and controllability of the system. Large control angle increases controllability of HVDC system and also increase the rating of the system which leads to a high price. Therefore it is important to determine a control angle at a first step of design procedure. This paper shows a rating trend of C.Tr, Valve and Filter due to control angle variation, and then introduces a determination process of the HVDC operating angle.

3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구 (A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

싸이리스터 제어 병렬 보상기에 의한 전력 제어 연구 (Power Flow Control of Thyristor Controlled Shunt Compensator)

  • 정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.680-683
    • /
    • 1999
  • A thyristor controlled shunt compensator, which is installed in the middle of the transmission line is adopted for controlling real power flow in a simple power transmission system. By means on the Fourier series representation of the thyristor switching action and the system parameters, the thyristor current equations are derived, which transmit the required real power of the simple power transmission system and inform the thyristor firing angle, the thyristor conduction angle, the power flows and the harmonic characteristics EMTP simulations at the various operating points show the dynamic characteristics of the thyristor controlled shunt compensator and correspond to the results calculated with the Fourier series representation.

  • PDF

교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발 (Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation)

  • 김성안;한성우;조윤현
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

임상가를 위한 특집1 - 근관치료에서의 레이저의 활용 (Lasers in Endodontics)

  • 허성윤;임은미;김선영;박상혁
    • 대한치과의사협회지
    • /
    • 제49권11호
    • /
    • pp.660-669
    • /
    • 2011
  • Er: YAG laser irradiation utilizing the newly developed RCLase side-firing spiral tip was used for the cleansing of root canals following their bio-mechanical preparation with ProTaper Ni-Ti files. The distal and palatal roots of 20 freshly extracted molar teeth were instrumented to size F3 with ProTaper files. In the experimental group (10 teeth) the pulp chamber and the root canals were filled with EDTA 17% and the root canals were lased for 30 s using the Er: YAG laser irradiation at 600 mJ per pulse and a frequency of 12 Hz. In the control group (10 teeth) the root canals were not lased. Scanning electron microscope analysis showed clean wall surfaces of the lased root canals with open dentinal tubules, free of smear layer and debris. In the scanning electron microscope photographs of the walls of the non-lased root canals a considerable amount of debris could be detected. It appears that an efficient cleansing of the root canal system can be achieved by using the Er: YAG laser irradiation with the RCLase Side-firing Spiral Tip following bio-mechanical preparation of the root canal with Ni-Ti Taper files.