• Title/Summary/Keyword: Firefighting System

Search Result 94, Processing Time 0.021 seconds

A Numerical Study on Coughed Particle Dispersion and Deposition in Negative Pressure Isolation Room according to Particle Size (음압격리병실에서의 기침 토출입자의 입경에 따른 확산 및 침적에 대한 수치해석 연구)

  • Jung, Minji;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.37-44
    • /
    • 2018
  • Purpose: This study investigates the influences of coughing direction and healthcare worker's location on the transport characteristics of coughed particles in airborne infection isolation room (AIIR), which is commonly called negative pressure isolation room, with a downward ventilation system. Methods: Computational Fluid Dynamics (CFD) was used to simulate the airflow and for tracing the behavior of particles. Results: The results show that the airflow pattern and coughing direction have a significant influence on the characteristics of particle dispersion and deposition. When healthcare workers are in the isolation room with the patient who is lying on the bed, it is recommended to be located far from the anteroom to reduce the exposures from infectious particles. And when the patient is lying, it is more effective in removing particles than when the patient is in Fowler's position. Although it is an isolation room that produces unidirectional flow, coughing particles can spread to the whole room and a large number of particles can be deposited onto patient, bed, side rails, healthcare worker, ceiling, floor, and sidewall. Implications: Following the patients' discharge or transfer, terminal cleaning of the vacated room, furniture, and all clinical equipment is essential. Also, it is necessary to establish detailed standard operating procedure (SOP) in order to reduce the risk of cross-contamination.

Exploratory study on the based on big data for fire prevention of multiple shops (다중이용업소의 화재예방을 위한 빅데이터 기반의 탐색적 연구)

  • Jeon, Byungkwan;Lee, Sung-Won
    • Journal of Industrial Convergence
    • /
    • v.16 no.4
    • /
    • pp.27-32
    • /
    • 2018
  • In this research, in order to prevent the fire of multiple users who are concerned about many human life damage, based on the statistical data of the National Fire Protection Agency's National Fire Information Center and the Fire Defense Administration Fire Defense Administration, Attempts were made on the exploratory approach to measures that can reduce the topic of. In this research, using the preventive firefighting administrative statistics of the Fire and Disaster Management Agency, we analyzed by focusing on the effectiveness of multiple users' firefighting safety education. Through analysis results we could infer that fire safety education does not have effectiveness in actual fire prevention. Through previous research, we found out that the cause is insufficient for the management of fire safety education, thereby deriving an improvement plan to develop a systematic fire safety education system.

Design and Control of a Firefight Cannon Manipulator Applying Sliding Mode Control

  • Vu, Mai The;Choi, Hyeung-Sik;Kang, Hyeon-Seung;Bae, Jae-Hyeon;Joo, Moon-G.;Joo, Yeong-do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.554-562
    • /
    • 2015
  • This paper describes an analysis of an architecture and control system of a firefighting cannon manipulator (FCM) composed of two joint axes and one water-shooting actuator. Because the orienting FCM motion is disturbed by the reaction force from water shooting, the water shooting force has been modeled for robust control. The dynamics model of the manipulator has been set up including the external force of water-shooting reaction on the manipulator. A PD Controller and Sliding Mode Controller have been designed and their performance been tested through simulation to track a desired trajectory under the disturbance of a water-shooting reaction. The simulation shows that the performance of the Sliding Mode Controller is better than that of the PD controller.

A Study on the Improvement of Disaster in Multiple Casualties (다수의 사상자 발생 재난 대응체계의 개선방안에 관한 연구)

  • Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.273-278
    • /
    • 2023
  • In this study, We conducted a survey for improvement about disaster in multiple casualties. Results, It was checked out many problems that Triage is inconvenience in using and damaging. And it was turned out that firefighting resources are not being put efficiently in the right place. Therefore, We are proposed that expansion of education and training opportunities, Location system of emergency activity resource in using App, Cope with a multiple casualties in using QR Code.

A Study of Computational Fluid Dynamics Analysis for the Water Spray Distance of Long Jet Monitor (Long Jet Monitor의 소화수 분사 거리에 대한 유동 해석적 연구)

  • Jae-Sang Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.907-913
    • /
    • 2023
  • Currently, the sprinkler method is widely used as an initial suppression method in existing firefighting systems. However, this method can cause significant damage to both equipment and facilities in the hydration area. To minimize this damage, fire extinguishing monitors are being developed that can spray fire extinguishing water directly at the point of fire. These monitors are installed on the top floor of the ship, such as the Living Quarter and Ventilation System. While conventional fire extinguishing monitors focus on lightweight research with a short spray port and require a spray distance of about 40 to 45m, recent developments necessitate a longer spray port, similar to a water cannon, requiring a spray distance of about 70 to 75m. This study aims to predict the injection distance of both the existing ship-installed fire extinguisher and the long spray port fire extinguisher through hydrodynamic computer analysis, and to determine whether the injection distance has increased.

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

A Study on the Management Plan of Fire Protection System Utilizing Urban Spatial Information (공간정보를 활용한 소방시설의 관리방안 연구)

  • Bang, Changhoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.98-104
    • /
    • 2019
  • This study examined the efficient management of a fire protection system using spatial information, and basic data for the development of related firefighting industry were obtained. To overcome the problems of malfunction and management failure, which are the major issues of fire protection system management, this study analyzed the related laws and regulations on building spatial information of a fire protection system to introduce spatial information to the fire protection system field. For efficient management of the fire protection system, it is necessary to revise the related laws of the fire protection system, such as protection system-related laws including space information technology, and maintain the standardization, effectiveness, and consistency of fire protection system spatial information.

A Study on the Establishment of an Integrated Management System for Forest Fire Prevention and Suppression Measures (산불예방 및 진압대책의 통합관리체계 구축 방안 연구)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.163-169
    • /
    • 2022
  • Recently, in Korea, if a very large forest fire occurs due to the people's carelessness, it is of great interest because it spreads into a large forest fire. If a wildfire spreads and becomes large, it will inflict great damage (appointment and property), and the damage is irreversible. The best way to extinguish a wildfire is to prevent it before it occurs. If a forest fire occurs due to a failure in prevention, the early firefighting activities to prevent the progress of the forest fire by promptly dispatching it by reporting it and approaching the site as soon as possible should now be managed with a systematic integrated management system. To do so, it is necessary to prepare a preventive system, such as issuing warnings for each weather condition by the Korea Forest Service, consisting of cooperation (support) activities for forest fire prevention by related organizations, etc. In order to minimize the loss of precious lives and forests, measures have been taken to establish a system, to establish a prompt and accurate situation reporting system, and to establish an integrated command system (ICS) for on-site commanders.

A Review on the Improvement of the Meaning and Composition Requirements of Interference with Fire Protection Activities - Focusing on Interference with 119 EMS Activities - (소방활동방해죄의 의미와 구성요건 개선에 관한 검토 -119구급활동 방해를 중심으로-)

  • Young Pyo Hong
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.3
    • /
    • pp.105-124
    • /
    • 2023
  • Modern society is facing an unstable environment due to unexpected accidents and hazardous situations. For example, incidents such as the collapse of the Bundang Bridge and the crushing accident in Itaewon could serve as examples. In addition to these, critical emergencies like sudden cardiac arrests and strokes frequently occur, requiring swift actions and smooth transfers to specialized medical institutions for effective responses. In response to these risks, the country has been establishing various systems to protect the lives and safety of its citizens. Among these, the 119 First Aid Activities plays a crucial role within the emergency medical system. Its goal is to promptly respond to critical emergency situations involving severe trauma patients or patients with serious illnesses, minimizing damage and safeguarding lives by swiftly transferring them to emergency medical institutions for specialized treatment. The core activity related to this is emergency rescue operations. In particular, the 119 First Aid system serves as a crucial institution responsible for the hospital transportation of emergency patients. However, rescue personnel still encounter cases of interference with their activities during their duties. Despite efforts from the police, these interference cases persist, and they share similarities with the crime of obstructing official duties. Interference with emergency activities exhibits a comparable nature to instances such as physical assaults and equipment damage against emergency medical practitioners working within the emergency medical system. Therefore, a comprehensive understanding and improvement efforts regarding the issues of interference that arise during the process of emergency medical activities, including the 119 First Aid system, are necessary. The solution to these problems is to establish and improve the conditions for obstruction of first aid activities, focusing on the "Framework Act on Firefighting" and the "Act on 119 Rescue and Emergency."

Design and Implementation of Building Control System based 3D Modeling (3D 모델링 기반 빌딩관제시스템의 설계 및 구현)

  • Moon, Sang Ho;Kim, Byeong Mok;Lee, Gye Eun
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.5
    • /
    • pp.673-682
    • /
    • 2020
  • Buildings are becoming more and more high-rise and large-scale in recent years, so in the event of a disaster such as a fire, enormous human and economic damage is expected. Therefore, management, security, and fire control are essential for large buildings in the city. Because these large buildings are very complex outside and inside, they need a three-dimensional control based on 3D modeling rather than a simple flat-oriented control. To do this, this paper designed and implemented a building control system based on 3D modeling. Specifically, we designed a 3D building / facility editing module for 3D modeling of buildings, a 3D based control module for building control, and a linkage module that connects information such as firefighting equipment, electrical equipment and IoT equipment. Based on this design, a building control system based on 3D modeling was implemented.