• 제목/요약/키워드: Firefighting System

검색결과 94건 처리시간 0.025초

건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구 (Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System)

  • 이원강;최충석
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

전국 소방력 동원령 운영 개선방안에 대한 연구 (A Study on the Improvement Plan for the Operation of National Fire Mobilization)

  • 이창목;이종호;지준근
    • 한국안전학회지
    • /
    • 제37권3호
    • /
    • pp.71-78
    • /
    • 2022
  • The purpose of this study is to improve the National Fire Mobilization Plan. This plan is a national-level comprehensive response system aimed to compensate for scarce firefighting resources and minimize damage from large-scale disasters that exceed the response limits of city and province firefighting forces. As such, relevant literature and domestic and foreign firefighting mobilization standards were reviewed, and simulations of firefighting mobilization were performed using the QGIS program to compare and analyze cases. Results showed that, as opposed to the current method of issuing mobilization orders by dividing resources according to city and province, recognizing the entire country as a single entity and prioritizing the mobilization of adjacent firefighting resources is more effective in terms of minimizing time and distance and more quickly securing resources. Regarding national firefighting mobilization, recognizing the country's firefighting resources as a whole will allow adjacent firefighting resources to be mobilized with priority. However, the mobilization-related limits of each region need to be set to respond to local disasters. Once the scale of mobilization is determined, a system that can quickly calculate how to mobilize firefighting resources based on location and distance can be established. Additionally, it is necessary to create an integrated management system so the central government can directly organize and mobilize local firefighting resources.

서울시 소방공무원의 방화장갑에 대한 평가 및 사용실태 (Evaluation of Firefighting Gloves and the Behavior Regarding their Usage, of Firefighting Officials in Seoul)

  • 김도희;남기범;오정우;이주영
    • 한국의류산업학회지
    • /
    • 제23권4호
    • /
    • pp.515-526
    • /
    • 2021
  • This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

법과 제도적 관점에서 본 소방특별조사의 개선방안 (A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System)

  • 이재욱;정기성
    • 문화기술의 융합
    • /
    • 제7권3호
    • /
    • pp.545-552
    • /
    • 2021
  • 2011년 8월 4일에 개정된 법률에 따라 소방특별조사는 소방시설의 유지·관리 등을 관계인(소유자·관리자·점유자)이 하고 이에 대한 책임도 관계인에게 주어졌다. 소방특별조사는 기존의 모든 소방대상물에 직접 출입하여 소방시설의 유지·관리 상태 등을 조사하는 대신에 매년 일부 대상물을 선별하여 방문하고 소방시설의 유지·관리 상태 등을 확인하고 잘못된 부분에 대하여 시정하고 그 책임에 대하여 과태료 등의 처분을 하는 것이다. 이 제도를 도입한 이유가 관계자의 책임을 강화하여 민간자율정정제도의 정착, 소방전문 인력의 부족, 빈번한 대민접촉에 따른 부패의 개연성과 소방검사에 따른 소방기관의 책임 등이 고려되었다. 그러나 소방특별조사제도를 도입하여서도 여러 가지 문제가 대두되고 있다. 소방안전을 위한 제도 중 하나인 소방특별조사는 관계 법령에 따라 소방대상물에 설치된 소방시설에 대하여 적합하게 설치·유지·관리되고 있는지를 관계 공무원, 특히 소방공무원이 확인하는 것이다. 소방특별조사는 1958년 소방법이 제정된 당시에 소방검사로 도입되어 최근까지 30여 차례의 개정과정을 거쳐, 현행 소방특별조사는 2003년 기존의 소방법체계가 4개의 법률로 분법화되면서 "화재예방, 소방시설 설치·유지 및 안전관리에 관한 법률"로 기존의 소방검사 소방특별조사로 변경되어 수용되었다.

Application of BIM on Drawing Verification of Firefighting

  • Chang, Ya-Chun;Shr, Jin-Fang;Huang, Xuan-Chao
    • International Journal of Aerospace System Engineering
    • /
    • 제2권2호
    • /
    • pp.15-18
    • /
    • 2015
  • In general, most of the function and using of building is for single purpose. However, current buildings combine several functions that causes a lot of problems not on firefighting only but also on environment engineering. Because of hard integration on different fields that causes a lot of conflict. That wastes cost and time. That also threaten the safety of firefighting. This search focuses on the drawing verification and field inspection on firefighting. These two items both remain paper work. To complete the current work, it needs to bring a great amount of drawing papers in the field. By BIM, integrated data can be extracted. It makes the drawing verification and field inspection easier and increases the efficiency. That is the main point of this research.

소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구 (A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP))

  • 이원강;최충석
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.29-34
    • /
    • 2012
  • 본 논문에서는 소방전원 및 소방전원 부족시 용량 보완을 위한 인터록 시스템의 한계점 등을 분석하고 소방전원 보존형 발전기(RFP)의 작동방법 등을 제시하여 화재와 같은 상황에 효율적으로 대응할 수 있는 방법을 제시하는데 있다. 소방전원보존형 발전기에서 일괄제어방식은 발전기에 과부하가 걸리면 소방전원보존용 제어기에서 신호를 발신하여 소방부하는 남겨두고 비상부하용 주차단기를 일괄 차단하고, 발전기가 마지막까지 소방부하에 전원이 공급되도록 한 시스템이다. 순차제어방식은 과부하가 걸리면 소방전원보존용 제어기에서 1차 신호를 발신하여 설정된 비상부하의 1단계 부하를 차단한다. 그리고 지속적인 감시 상태에서 소방부하가 증가하여 발전기가 다시 과부하가 걸리면 제어기에서 2차 신호가 발신하여 비상부하의 2단계 부하를 차단하는 시스템이며 각각의 작동 상태를 표시하는 표시장치를 가진다.

국내발전소 소방안전경영시스템구축을 위한 실태평가에 관한 연구 (Evaluation of the Actual Conditions for the Construction of a Firefighting Safety Management System in Domestic Power Plants)

  • 강길수;최재욱
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.89-98
    • /
    • 2018
  • 2015년 베이징 화력발전소 화재사고나 2012년 보령화력과 2016년 태안화력 등 국내 발전소 화재사고, 2011년 후쿠시마 원전참사나 2001년 캘리포니아 대정전은 전력관련 소방안전사고로 국민의 안정적 생활과 국가적인 손실을 가져온 사례로 손꼽고 있다. 전기는 국민생활과 경제에 미치는 영향이 절대적이라 위험성이 높은 대용량의 석탄, 가스 및 원자력 등을 연료로 사용하여 전력을 생산하는 발전소가 안전관리의 소홀로 인한 화재폭발사고나 방사능누출, 지진 등 자연재해로 인한 문제가 생길 경우 국민의 생명보호와 재산손실에 직접적 피해뿐만 아니라 경제성장에 미치는 심각한 상황을 우리는 충분히 예상할 수 있다. 본 연구에서는 한국남부발전 등 5개 발전사 및 한수원 소방안전담당자를 대상으로 발전소 소방안전경영시스템 구축의 필요성에 대한 실태조사를 통해 소방전담조직 보강과 전문역량강화 프로그램 운영, 체계적인 소방안전관리를 위한 발전소 맞춤형 소방안전경영시스템의 개발, 최근 이슈가 된 지진에 대비한 내진 대응체계 강화를 개선방안으로 도출하였다.

석유화학공장의 소화설비에 관한 연구 (A Study on the Firefighting Equipment in Petrochemical Plants)

  • 김봉훈;최재욱;임우섭
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.14-22
    • /
    • 2014
  • 석유화학공장에서 화재 폭발사고는 매년 반복되고 있으나 화재 방호시스템에 관한 국내 법규는 최악의 화재 시나리오에 대응하기에는 미흡한 실정이다. 이에 본 연구에서는 석유화학공장에서 국내외 화재 방호시스템의 기준을 비교 분석하고 울산국가산업단지 석유화학공장 32개소의 소화설비 현황을 조사하였다. 결론적으로 석유화학공장에서 소화용수는 최악의 화재 시나리오를 기반으로 하여 설계하고 고정식 물분무 설비, 고가 모니터 노즐, 워터커튼 설비, 대용량 포모니터 설비와 같은 소화설비가 최악의 화재 시나리오에 대비하여 설치되어야 할 것으로 나타났다.

아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석 (An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building)

  • 손주달;공하성
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

한국 소방용 방화복에 대한 만족도 조사 (A Survey of Korean Firefighters Regarding their Satisfaction with Protective Clothing)

  • 한설아;남윤자;최영림
    • 복식
    • /
    • 제58권9호
    • /
    • pp.166-175
    • /
    • 2008
  • For the structural firefighting protective clothing, it can show a synergy effect when it satisfies smart fabric to block off a harmful environmental element and ergonomics design that apply range of motion of human body and appropriate size system. There are various standards about the structural firefighting protective clothing, but it's difficult to find a rule about movement suitability because the performance of the material holds a lot of the rules. Therefore, the purpose of this study is to propose a scheme to evaluate the current structural firefighting protective clothing and to improve movement suitability by research on the actual condition. For this, the survey about wearer acceptability scale on design and size and about improvement requirements was executed gathering firefighters' opinion. Questionnaire was composed with 23 items about satisfaction on current structural firefighting protective clothing, body suitability, movement suitability, improvement requirement and subjective information. As a results, Korean firefighters demand ergonomics design of structural firefighting protective clothing which to minimize restriction of body movement and to maximize body suitability.