• Title/Summary/Keyword: Firefighting Activities

Search Result 32, Processing Time 0.021 seconds

Utilization of the robot's field of fire prevention research (로봇의 소방방재분야 활용방안 연구)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.471-484
    • /
    • 2013
  • Large and complicated firefighting environment is accelerating in the early activities in the field of fire officials at the time limit situation leads to people's lives and property damage, as well as the loss of the Fire Service. Therefore, the state-of-the-art technology that can respond to rapidly changing fire environment urgently in the field of fire fighting have been introduced should be utilized. These intelligent firefighting robots build daegukmin firefighting safety net that can be used when. Other advanced technology industries, the most effective ways that can be introduced into the firefighting shall be provided in the current situation of the industry's initial firefighting robots.

  • PDF

Anthropometric study of the head for the development of firefighting hoods for firefighters (소방공무원의 방화두건 제작을 위한 머리 치수 연구)

  • Jeong, Da Wun;Jang, Mina;Kwon, Chae-Ryung;Kim, Dong-Eun;Lee, In Seong
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.5
    • /
    • pp.670-681
    • /
    • 2017
  • Firefighting hoods protect the head, face, and neck areas of officials while they perform firefighting services. The purpose of this study is to investigate the head size of Korean firefighting officials in order to establish the dimensions necessary to construct firefighting hoods. A total of 98 male firefighting officials participated in this study and 11 body dimensions, necessary for the construction of firefighting hoods, were measured. The data collected from the firefighting officials were compared to the general adult male data from the Size Korea national anthropometric study. The heights, weights, head circumferences, head heights, and bitragion arcs of the firefighters were significantly larger than those of general adult males, which shows that firefighting officials generally have larger body and head sizes than general adult males. Based on the results of Pearson's correlation coefficients, head circumference and head height were judged to be the important measurements for the construction of the firefighting hoods. Thus, these two measurements were chosen as the basic dimensions of the cross tabulation analysis. As a result, head circumferences of 57.00~60.99cm and head heights of 23.00~25.99 cm were found to be important measurement ranges among the firefighters. This study is expected to be used as the basis for the creation of firefighting hoods that help to ensure the safe rescue activities for firefighting officials.

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

The Effect of Various Hot Environments on Physiological Responses and Information Processing Performance Following Firefighting Activities in a Smoke-Diving Room

  • Hemmatjo, Rasoul;Motamedzade, Majid;Aliabadi, Mohsen;Kalatpour, Omid;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • v.8 no.4
    • /
    • pp.386-392
    • /
    • 2017
  • Background: Fire service workers often implement multiple duties in the emergency conditions, with such duties being mostly conducted in various ambient temperatures. Methods: The aim of the current study was to assess the firefighters' physiological responses, information processing, and working memory prior to and following simulated firefighting activities in three different hot environments. Seventeen healthy male firefighters performed simulated firefighting tasks in three separate conditions, namely (1) low heat (LH; $29-31^{\circ}C$, 55-60% relative humidity), (2) moderate heat (MH; $32-34^{\circ}C$, 55-60% relative humidity), and (3) severe heat (SH; $35-37^{\circ}C$, 55-60% relative humidity). It took about 45-50 minutes for each firefighter to finish all defined firefighting activities and the paced auditory serial addition test (PASAT). Results: At the end of all the three experimental conditions, heart rate (HR) and tympanic temperature (TT) increased, while PASAT scores as a measure of information processing performance decreased relative to baseline. HR and TT were significantly higher at the end of the experiment in the SH ($159.41{\pm}4.25beats/min$; $38.22{\pm}0.10^{\circ}C$) compared with the MH ($156.59{\pm}3.77beats/min$; $38.20{\pm}0.10^{\circ}C$) and LH ($154.24{\pm}4.67beats/min$; $38.17{\pm}0.10^{\circ}C$) conditions (p < 0.05). There was no significant difference in PASAT scores between LH and MH (p > 0.05). Nonetheless, there was a measurable difference in PASAT scores between LH and SH (p < 0.05). Conclusion: These consequences demonstrate that ambient temperature is effective in raising the physiological responses following firefighting activities. It is therefore argued that further increase of ambient temperature can impact firefighters' information processing and working memory during firefighting activity.

A Study on the Reorganization of Fire Service Agencies (소방기관의 조직 개편에 관한 연구)

  • Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.279-284
    • /
    • 2023
  • In this study, We analyzed that organization of fire service agencies, personnel management and firefighting activities. As a results, Many problems were found out, about ratio of administrative to firefighting personnel, retirement age, promotion, employment, Etc. T herefore, In order to carry out there mission faithful in disasters scene, We proposed that reduction of the number of administrative firefighter, abolition of the employment system candidates for fire executive positions, reducing of the retirement age and changing of the promotion system.

Safety Measure Developed Through Analysis of Firefighters' 『Investigation Report on Accidents to On-Site Workers』

  • Jo, Chang-Hyun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.334-344
    • /
    • 2021
  • The study has suggested a way to minimize safety accidents found in on-site firefighting activity by analyzing firefighters' [investigation report on accidents to on-sie workers]. The study result is described as follows. First, the result of [investigation report on on-site workers] shows that while accidents are found to most frequently have occurred to low-ranking firefighting officers such as Sobangsa and Sobanggyo and firefighting officers with career of less than 5 years, fire-extinguishing activity proved to be the most prone to accidents in the category of activity. Second, analysis performed to identify variance between injury extent and area based on cause of accident shows statistically significant variance. In addition, the result of verifying difference in cause of accident based on category of activity shows significant difference with 'falling over and sliding' being the highly likely cause of accident in fire containment and rescue activities and 'reckless move' being highly likely case of accident in emergency activities. Third, the result of verifying factors behind the extent of injury done to on-site workers shows that when accident is caused by 'incomplete behavior', it was found that the extent of injury is substantial. It was also found that rescue activity is accompanied by substantial extent of injury. As a solution to this, the study suggested ways to establish, extend and operate safety-specific curriculum for entrants, develop materials regarding risk prognosis training and explicate training-related regulations, set up safety management measure for a single squad team, upgrade performance of private protection equipment, institutionalize SOP by on-site activity stage, materialize and activate swift rescue team and increase objectivity and proficiency of safety accident investigation.

Producing Firefighting Vulnerability Maps Using GIS - A Case Study of Dalseo-gu, Daegu - (GIS를 이용한 화재진압 취약성 지도 제작 - 대구광역시 달서구를 사례로 -)

  • KIM, Sung-Jae;CHOI, Gap-Yong;CHANG, Eun-Mi;SONG, Wan-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.3
    • /
    • pp.11-20
    • /
    • 2015
  • Fire incidents, which occur every year, cause huge damage to properties and humans. Significant time and costs have been invested in minimizing and responding to such accidents. With the recent advances in the development of spatial information, in the firefighting field, studies have been conducted to effectively bring fires under control using GIS(Geographic Information System). Most of such studies, however, focused on individual analyses of firefighting-related factors, but comprehensive research on the vulnerability factors in fire control activities, a major part of firefighting activity, has yet to be done. This study sought to pinpoint and analyze the factors that obstruct fire controlling, and to gather relevant data and create GIS-based databases. Based on such database, GIS-based overlay analysis was conducted to produce a fire control vulnerability map. The findings of this study will enable a quantitative analysis of firefighting obstruction factors to assist the personnel engaging in firefighting in rational decision-making, such as in formulating a firefighting operation plan for securing golden time.

A Study on the Development of Training Content Scenarios for On-Site Commanders Engaged in Firefighting Activities (소방활동 현장지휘관 훈련용 콘텐츠 시나리오 개발에 관한 연구)

  • Chun, Woo-Young;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.141-146
    • /
    • 2020
  • This study examines the development of content scenarios to facilitate the training of on-site commanders in firefighting activities. To establish the training content scenario system, the three core competencies of the on-site commanders were set as situation judgment, communication, and decision-making. A system of scenarios was established to actively reflect these three core competencies when designing the scenarios. All the contents of these scenarios are based on Standard Operating Procedures (SOP). The scenarios comprise 14 stages that are divided into four steps with the exception of stages 1 and 14, which mark the beginning and end of the training. It consists of the situation setting stage and the first, second, and third decision-making stages. Specifically, situation judgment and communication are important factors in each stage.

The Risk and Countermeasures of Asbestos Exposure at the Scene Activities of Fire Officials (소방공무원들의 현장 활동 시 석면노출의 위험성과 대응방안)

  • Lee, Jung-Il
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.68-78
    • /
    • 2010
  • The purpose of this study, fire officials during the field activities find causes fugitive dust of containing asbestos is the seriousness of the phenomenon is a threat case and through questionnaires, during on-site activities to prevent exposure to asbestos is effectively. Analysis of the relationship to field activities of fire officials and about the dangers of asbestos dust, asbestos cancer caused by asbestos, and to protect fire officials from the same disease like malignant mesothelioma, by varying the conditions of irrational, fire officials at the scene activities in advance of a deadly hazard is aimed to eliminate through optimization of organizational management and a safe and pleasant working conditions for fire officials through the deadly hazards at the scene of action is aimed to obviate. Also according to asbestos exposure by wearing protective equipment as well as thoroughly strengthen firefighting, firefighting awards to recognize the seriousness of the hazard factors, disease and provide compensation to the legal system, for diseases not yet recognized officially recognized by disaster supplemented by institutional, fire officials to improve morale and working conditions, etc. versus expectations is to improve public services.

A Research on the Improvement & Actual Situation of Duplicated Safety Inspections for Facilities (시설별 안전점검 중복성에 대한 실태조사 및 개선방안 연구)

  • Park, Jongkeun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 2017
  • Safety inspection activities of the facilities including the electricity, gas, building, and firefighting, etc. are individual checks by the separate law of each government department, comprehensive inspections for the specific managed facilities or during a weak season, and national safety overall diagnostics for the disaster prevention. Thus, types of the inspections are various and they have been carried out repeatedly as well as duplicately. That can make the people or institutes to take such inspections feel great burdens. Therefore, the investigation on the current situation of the individual inspection by the separate law for the electricity, gas, building, and firefighting, etc. as well as of various others by the government needs to be carried out and according to the results the repetitive and duplicated inspections should be reduced and converged to one comprehensive one. In this regard, we proposed solutions to improve the government safety inspection system, function, and role.