• Title/Summary/Keyword: Fire.explosion

Search Result 637, Processing Time 0.032 seconds

A Study of Evacuation Route Guidance System using Location-based Information (위치기반 정보를 활용한 비상대피경로 안내 지원시스템 개발)

  • Kim, Ho-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.18-23
    • /
    • 2017
  • The shipyard quay process struggles to control workers and maintain a secure working environment because of the presence of at least 1,000 people. Therefore, safety accidents such as an explosion or a fire are likely to occur. With the recent increase in safety accidents at shipyards, the requirements for safety and process monitoring have been strengthened. Major shipyards are conducting researchto monitor the process in real time and to detect the work environment for safety. In this paper, we propose a safe and accurate evacuation route based on the information of the dangerous area and the user's location based on a mobile application to reduce the casualty accidents in the presence of many personnel in a concentrated area. To do this, we analyze the trend of the fire escape system on the ground building, compare various algorithms for escape route calculation, select appropriate algorithms for this study, and perform programming. A basic experiment was conducted to confirm the results. The proposed method is expected to be used in large ship construction sites, passenger ships and large public facilities to reduce accidents in the case of a safety accident.

Measurement of flash point for binary mixtures of Ethanol, 1-propanol, 2-propanol and 2,2,4-trimethylpentane (Ethanol, 1-propanol, 2-propanol 그리고 2,2,4-trimethylpentane 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • Flammable substances, such as organic solvents, are commonly used in laboratories and industrial processes. The flash point of flammable liquid mixtures is a very important parameter for characterizing the ignition and explosion hazards, and the flash points of mixtures of $C_2{\sim}C_3$ alcohols and 2,2,4-trimethylpentane were measured in the present study. The 2,2,4-trimethylpentane is an important component of gasoline and is frequently used in the petroleum industry as a solvent. Lower flash point data were measured for the binary systems {ethanol + 2,2,4-trimethylpentane}, {1-propanol + 2,2,4-trimethylpentane}, and {2-propanol + 2,2,4-trimethylpentane}. The flash point measurements were carried out according to the standard test method (ASTM D3278) using a Stanhope-Seta closed cup flash point tester. The measured flash points were compared with the predicted values calculated using Raoult's law and also following $G^E$ models: Wilson, Non-Random Two Liquid (NRTL) and UNIversal QUAsiChemical (UNIQUAC). These models were able to predict the experimental flash points for different compositions of {$C_2{\sim}C_3$ alcohols + 2,2,4-trimethylpentane} mixtures with minimal deviations. The average absolute deviation between the predicted and measured lower flash point was less than 1.28 K. A minimum flash point behaviour was observed in all of the systems as in the many observed cases for the hydrocarbon and alcohol mixtures.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

A Clinical Study on Treatments of Hwabyung with Oriental Medicine (홧병환자의 한의학적 치료에 대한 임상적 연구)

  • Kim, Jong-Woo;Whang, Wei-Wan
    • The Journal of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.5-16
    • /
    • 1998
  • Hwabyung is a common emotional disorder which has symptoms expressed like firt's explosion in middle-aged after long period of emotional suppression among Koreans. It is similar in its characteristics such as neurosis, anxiety, panic attacks in Western Medicine, though the treatment method was not effective. So we have done a clinical research on Oriental Medical Method, especially on Acupuncture Therapy, and obtained following results. 1. Patients with Hwabyung complained of pressure pain around the Chunjung(?中, CV-17) point distinctively. About 70% of those were located on the CV-17 point, 25% were 1cm upper than the CV-17 point and 5% of those were 1cm lower point than the CV-17 point. 2. Degrees of pressure pain were divided into 5 grades from ade 1(feeling pain with slight pressure) to grade 5(feeling no pain with severe pressure), respectively. 3. Patients with Hwabyung showed various symptoms compared to fire's explosion such as anger, chest discomfort, difficulty in breathing. tachycardia. and feeling of epigasfric mass etc., and the degrees were divided into 5 grades according to the severities from grade 1(can't keep their usual living) to grade 5(no complaints with heavy stresses), respectively. 4. For the treatment of Hwabyung in this study, we had given Acupuncture therapy on some points such as Chunjung:?中:CV-17, Jungwan:中脘:CV-12) and Chunchu:天樞:S-25, etc. for 15 minutes a time twice a week. And Bunshimkiumgmnihang(分心氣飮加味方) was administered 3 times a day. 5. About 40% of the patients took treatment for more than 2 months, 29% of those took 1 to 2 months and 31% of those took less than 1 month. In this study, we excluded those who stopped treatment within a month without any expected effects. 6. We evaluated the changes of severity of pain according to the following categories such as - for no change, + for 1 grade, ++ for 2 grades, +++ for 3 grades, and ++++ for 4 grades of improvements. Among the patients taken 1 to 2 months of treatment. 48% of the those showed +, 7% of those showed ++, 3% of those showed +++ and 41% of those showed no change. Among the patients taken less than 2 months of treatment, 20%of those showed +, 40% of those showed ++, 28% of those showed +++ and 13% of those showed no change. 7. We evaluate the changes of symptoms according to the following categories such as - for no change, + for 1 grade, ++ for 2 grades, +++ for 3 grades and +++ for 4 grades of improvements. Among the patients taken 1 to 2 months of treatment, 34% of those showed +, 14% of those showed ++ and 52% of those showed no change. Among the patients taken more than 2 months of treatment, 20% of those showed +, 43% of those showed 20% of those showed +++, 3% of those showed +++ and 15% of those showed no change. 8. When we compare the changes of pain and symptoms according to the periods of treatment, the changes in quantity of pain in 1 to 2 months group was $0.72{\pm}0.75$, in more than 2 months group was $1.83{\pm}0.98$, and the changes in quantity of symptoms in 1 to 2 months group was $0.62{\pm}0.73$, in more than 2 months group was $1.75{\pm}1.03$. According to the above results, we have concluded that more than 2 months of treatment is more beneficial than 1 to 2 months of treatment.

  • PDF

An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers (멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구)

  • Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Liquefied gas carriers generally transport cargoes of flammable or toxic nature. Since these cargoes may cause an explosion, fire or human casualty, the accommodation spaces, service spaces and control stations of liquefied gas carriers should be so located as to avoid ingress of gas. For this reason, the paragraph 8.2.9 of IGC Code in IMO requires that the height of vent exits should be not less than B/3 or 6 m whichever is greater, above the weather deck and 6 m above the working area and the fore and aft gangway to prevent any concentration of cargo vapor or gas at such spaces. Besides as known, the LNG market has been growing continually, which has led to LNG carriers becoming larger in size. Under this trend, the height of a vent will have to be raised considerably since the height of a vent pipe is generally decided by a breadth of a corresponding vessel. Accordingly, we have initiated an examination to find an alternative method which can be used to determine the safe height of vent masts, instead of the current rule requirement. This paper describes the dispersion characteristics of boil-off gas spouted from a vent mast under cargo tank cool-down conditions in the membrane type LNG carriers.

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가)

  • Song, Jung Soo;Yu, Jong Min;Han, Seung Youn;Choi, Jeong Woo;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • The proportion of natural gas-fueled power generation is expanding due to the change of domestic energy policy pursuing reduction of dust and increasing clean energy consumption. Natural gas fuels used for the combined-cycle power plants and the district-heating power plants are operated at high temperature and high pressure in the fuel supply system. Accidents due to leakage of the gas such as fire and explosion should be prevented by applying risk management techniques. In this study, risk assessment was performed on the natural gas fuel supply system of a combined power plant based on the API RP 581 RBI code. For the application of the API RBI code, lines and segments of the evaluation target system were identified. Operational data and input information were analyzed for the calculations of probability of failure and consequence of failure. The results of the risk assessment were analyzed over time from the initial installation time. In the code-based evaluation, the gas fuel supply system was mainly affected by thinning, external damage, and mechanical fatigue damage mechanisms. As the operating time passes, the risk is expected to increase due to the external damage caused by the CUI(Corrosion Under Insulation).

Stability Characteristics based on Crane Weight of Small Fishing Vessels Under Standard Loading Conditions: Investigation Report of the Capsize Accident at Goseong Port (크레인 교체에 따른 표준재화 상태에서의 소형 어선의 복원성 특성 - 고성항 전복 사고 재결서 중심 -)

  • Kang, Dae Kon;Lee, Gun Gyung;Lee, Jun Ho;Han, Seung Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.1
    • /
    • pp.22-30
    • /
    • 2020
  • In March 2016, a 6.67-ton fishing boat capsized owing to the loss of stability during crane operations. Capsizing occurs when a boat or ship is flipped over (or turned upside down) for reason other than accidents caused by collisions, contact, stranding, fire or explosion. Over the past nine years (2010-2018), capsize accidents have accounted for 2.34 % of all marine accidents and are gradually increasing. The loss of stability from improper shipping is the main cause of most capsizes, especially for small fishing vessels weighing 10 tons. According to the Fishing Vessel Act, small fishing vessels weighing less than a ton are exempted from inspections on stability and load cranes. This study analyzes the issue cited as the reason for the capsizing of the small fishing boat in Goseong, namely, the reduction of restoring moment due to increased weight of the crane. Fishing boats with similar loading conditions were modeled on the basis of re-determination, and their stability before and after the accident was assumed. The fishing boats with heavier cranes were found to be at higher risk of capsizing owing to the reduction of the restoring moment and the angle of deck immersion. Under standard loading conditions, the stability moments of fishing vessels are lesser during fishing, compared to when they depart from or arrive at the port.

Development of Laboratory Safety Management System for Chemistry and Chemical Engineering Laboratory (화학 및 화학공학 실험실의 안전관리 시스템 개발)

  • Yoo, Jin Hwan;Lee, Heon Seok;Choi, Joung Woo;Seo, Jae Min;Park, Chulhwan;Ko, Jae Wook
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.376-382
    • /
    • 2008
  • There are many accidents such as fire and explosion in laboratories that have caused a great loss to lives and property in spite of the effort to the enhancement of laboratory safety level for years. Development of laboratory safety management system is a necessary to improve safety level because the accidents of similar types have periodically occurred in laboratories. The laboratory safety management system may reduce many accidents and a serious loss in laboratory. In this study, we summarized major items for a risk management and safety improvement based on the analysis results of various accidents in the laboratories. And then the laboratory safety management system was developed containing a laboratory safety management manual, a laboratory management system, a education management system, a MSDS (material safety data sheet) management system and a laboratory safety audit system. It may have a potential application for the laboratory safety management in the chemical laboratories.

A Study on the Hazardousness and the TLV in Working Environments of Benzine (벤진의 유해 위험성과 작업환경 노출기준 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jung-Hee;Shin, Jea-Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.233-244
    • /
    • 2006
  • Of many volatile organic detergents for metals, benzine(CAS No. 8030-30-6), of which the toxicity has not yet been proven, has been used as an alternative of the halide compounds in the consideration of toxic effects, global warming and the destruction of ozone layer. In order to evaluate the effects of the benzine on human body by investigating the subchronic inhalation toxicity, to obtain the basic data for establishing the criteria of exposure in working environments and to classify the hazardousness in compliance with the Industrial Safety and Health Act by evaluating the hazardousness, repeated inhalation exposure test was carried with SD rats. The rats were grouped by 10 females and males each. The repetitive inhalation exposures were carried out at 4 levels of concentration of 0 ppm, 60 ppm, 300 ppm, and 1,500 ppm, for 6 hours a day, 5 days a week, for 13 weeks. The results are described hereunder. 1. No death of the animals of the exposed and controlled groups in the test period. Not any specific clinical symptoms, change in feed intake quantity, abnormality in eye test, or change in activity were observed. 2. In the 300 ppm and 1,500 ppm groups, weight reduction in the female groups and weight increase of liver and kidney in the male groups compared with control group were observed with statistical significance(p<0.05). 3. In the blood test, the HCT increased in the male 300 ppm group and the number of hematocyte increased, MCV and MCH decreased in the male 1,500 ppm group. In the female 1,500 ppm group, the HB decreased and the distribution width of the hematocyte particle size increased. In the blood biochemistry test, the TP in the male 1,500 ppm group and the LDH in the female 1,500 ppm group were increased with statistical significance(p<0.05). 4. Under the test conditions of the present study with SD rats, the NOEL was evaluated to be from 60 ppm to 300 ppm for both male and female groups. By extrapolation, the NOEL for human who work 8 hours a day was evaluated to be from 128 ppm to 640 ppm 5. Since the NOEL evaluated in this study do not exceed 60ppm(0.184 mg/L) the test material does not belong to the classification of the hazardous substance "NOEL${\leq}$0.5mg/L/6hr/90day(rat), for continuous inhalation of 6hours a day for 90 days" nor to the basic hazardous chemical substance class 1(0.2 mg/L/6hr/90day(rat) defined by the GHS which is a criteria of classification and identification of chemical compounds. However, considering the boiling point($30-204^{\circ}C$), flashing point($-40^{\circ}C$), vapor pressure(40 mmHg), and the inflammable range(1.0 - 6.0 %), sufficient care should be taken for handling in the safety aspects including fire or explosion.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.