• Title/Summary/Keyword: Fire-related laws

Search Result 63, Processing Time 0.02 seconds

Related Laws and Performance Criteria for Public Service Drones for Disaster Safety (재난안전드론 도입을 위한 법규 및 성능기준 기초연구)

  • Kim, Noh Joon;Lee, Sung Eun;Kim, Hwang Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.150-155
    • /
    • 2016
  • This study is to suggest legislation and criteria for public service drones for disaster safety in order to enhance the research and development of the drones by helping setting right direction of the R&D. Many foreign governments are now conducting research and development on using drones as public service for disaster safety. Although there are also some efforts to using drones for public service in Korea, domestic laws and performance criteria for the drones for the purpose have not prepared yet. To set a right direction of the R&D, the laws and criteria shall be legislated and established immediately and then we can enhance the efforts to develop related technology for the drone. So this study proposed a performance criteria to fit various circumstances and situations by analyzing the aviation law in overseas. We hope this study can help R&D on the public service drones for disaster safety.

Problems and Reform Measures of Fire-Fighting Safety Management on the Skyscrapers (초고층 건축물 소방안전관리의 문제점과 개선방안)

  • Choi, Man-Chul;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.113-123
    • /
    • 2009
  • The number of high-rise buildings already constructed and/or being constructed is getting increased both domestically and internationally, for example, Lotte World 2 in Seoul and Taipei 101 in Taiwan, respectively. Maintenances of those skyscrapers, especially in fire-fighting safety, would be different from those of conventional buildings and are one of keen issues. In this study, the features of risks in aspects of fire-fighting safety for the buildings are investigated and the corresponding fire safety measures are proposed to prevent the disasters and to minimize the personal and property damages from it. The proposals include the specialization in self fire-fighting managements, the realization of self fire-fighting maintenance, the establishment of the integrated fire-fighting system, and the correction of inconsistencies in related laws on fire-fighting safety.

The Study on the Legal Improvement for Fire Protection in Wooden Architectural Heritage (목조건축 문화재의 화재방호를 위한 법규 개선에 관한 연구)

  • Kim, Dong Cheol;Roh, Sam Kew;Ham, Eun Gu
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2015
  • This study covers securing legal systems and institutions regarding the standards for installing fire prevention facilities to prevent fire on wooden architectural heritage. Conflicts among relevant laws were revealed and problems related to fire prevention performance, technical standards, responsibilities, etc. in the process of establishing legal fire prevention equipment and the equipment for self-extinguishing were identified through pondering over current legal systems of fire prevention facilities. To resolve the problems, at least the principle to preserve original shapes of wooden architectural heritage should be secured even though fire prevention facilities are installed and the installation process should be regulated by laws considering features of fire on wooden architectural heritage so that fire prevention performance can be guaranteed. The directions to improve installing system through legalization of design, construction, and audit review institutions and legalization of the technical standards for fire prevention facilities were suggested to guarantee performance when establishing fire prevention facilities for wooden architectural heritage.

A Study on the Need for Improvement of Fire Resistance Design in Underground Parking Lot due to Electric Vehicle Fire (전기자동차 화재에 따른 지하주차장 내화설계 개선 필요성 검토)

  • Kim, Hae-na;Park, Jun-Seo;Shin, Joung-Hyeon;Hong, Sang-Hun;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.235-236
    • /
    • 2022
  • Electric vehicle fires in underground parking lots are very dangerous, but it is judged that the current related laws and regulations do not change, which will cause problems. As a result of the analysis for the purpose of providing an electric vehicle in an underground parking lot, fire-resistance coating is essential as it can cause an explosion in the building members made of high-strength concrete when an electric vehicle fire occurs in an underground parking lot. Since a fire occurs, it is necessary to prevent electric vehicles from parking adjacent to each other.

  • PDF

A Study of Institutional Improvements for Responding to Electric Vehicle Fires: Focusing on the Case of Seoul (전기자동차 화재 대응을 위한 제도적 개선 방안 연구: 서울시 사례를 중심으로)

  • Nam-Kwun Park;Seung-Hee Ham
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.32-39
    • /
    • 2024
  • Purpose and Method: This study aims to suggest institutional improvements to enhance the response to electric vehicle fires. To this end, we examined the prevalence of electric vehicles, fires, and related legal systems in Seoul. Results: The top-level laws and ordinances related to electric vehicles are centered on distribution policies, so there is no practical fire response plan for electric vehicle fires. In order to apply the same regulations to each local government, it is necessary to set standards and establish a system for firefighting and safety facilities in higher laws. Conclusion: Establishing standards for the installation of fire and safety facilities that take into account the characteristics of electric vehicle fires and improving related systems will ultimately lead to an increase in the penetration rate of electric vehicles.

High-rise buildings in the general direction of the Fire Safety Management Study (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choe, Man-Cheol;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

A Study on Enhancing Institutionalization on the Fire Analysis of the Warehouse at Icheon City (이천 냉동창고 화재분석을 통한 제도개선방안 연구)

  • Jung, Tae-Ho;Park, Sang-Hyun;Kim, Hee-Kyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.80-84
    • /
    • 2008
  • This research has been carried out in order to provide countermeasure plans, fire prevention, improving institutional plans through analyzing accidental causes and investigating the situation of damage from the fire incident of the cold storage at Icheon. By the analysis of the incident, which is organized the process; for incidence, firstly a field investigation, next the overview of related laws, finally the analysis of problems and deducting suggestions, it was possible to find out the causes of casualties. We also suggested improving plans through finding out several problems such as safety management system and safety regulations, the permit on the completion of the cold storage and the completion examination of fire facilities as institutional problems and fireproof construction and the selection of finishing materials.

  • PDF

A Study on Revise the Rule of Safety Controllers of Hazardous Substances (위험물 안전관리 제도의 개선에 관한 연구)

  • Park, Kyong-Jin;Shin, Soo-Kyung;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.473-480
    • /
    • 2020
  • In this study, I analyzed problems of safety management system of hazardous substances and proposed improvement measures. By statistics of Korea National Fire Agency it shows that hazardous substances of not less than a designated quantity were 2,180 factorys, 24,732 handling places and 85,218 storing places in 2018. also It has been conformed that Fire accidents break out year after year in factory, etc. so In this study, I analyzed the safety controllers of hazardous substances of the present law and fire statistics. therefore I has been found out the problems that the first, safety controllers' status. the second, There is no laws related design, installation, installation supervision. the third, fire safety inspection. This study will be used a basic data for preventing of extensive hazazardous substances-related accident that is very difficult handling.