• 제목/요약/키워드: Fire-load

검색결과 513건 처리시간 0.024초

건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 - (Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building -)

  • 남동군;장곡견웅이;사공성호;정종진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

화재하중에 따른 지하생활공간의 화재성상 예측 (Prediction of the Fire Behavior According to the Fire Load in an Underground Life Space)

  • 채한식;석창목;김이성;이지희;김화중
    • 한국화재소방학회논문지
    • /
    • 제21권1호
    • /
    • pp.51-59
    • /
    • 2007
  • 본 연구에서는 대구에 위치한 G 지하생활공간을 대상으로 화재하중에 따른 화재성상을 분석하였다. 화재성상 예측시 화재온도나 화재지속시간을 좌우하는 인자인 화재하중 및 환기계수를 파악하기 위하여, 현장방문을 통하여 가연조건을 조사하고 실의 용도별 가연조건에 대하여 각 재료의 단위발열량을 이용하여 화재하중을 산정하였다. 또한, 산정된 실의 화재하중을 변수로 화재성상분석을 위한 6가지 모델의 축소실험을 행하고 화원의 시간에 따른 온도변화와 화원의 온도상승으로 인한 공간내부로의 열유동 분포를 중심으로 화재성상을 분석하였다.

건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상- (Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore -)

  • 남동군;장곡견웅이;정종진;임우섭;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

대형서점 적재가연물의 초기 연소발열성상 (Heat Release Characteristics of Typical Live Fire Load in Large Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.88-94
    • /
    • 2011
  • 건축물 적재가연물의 연소성상 및 발열특성은 건물 내부의 화재전파속도와 화재규모 등을 크게 좌우하는 중요한 요인이다. 그러나 대형 서점의 적재가연물은 다른 건축용도에 비해 다량 적재되어 있기 때문에 화재시 건물 전체의 화재피해가 대형화할 가능성이 있지만 연소발열성상이 화재실험 등으로 파악되어 있지 않다. 따라서 본 연구는 대형서점의 적재가연물인 목재 서가 등을 재현한 시험체를 대상으로 연소실험을 실행하여 연소발열성상을 파악하였다. 또한 이 결과를 바탕으로 대형서점의 화재시 화재안전성을 검토하고 대형 서점의 화재안전설계에 필요한 적재가연물의 연소표면적당 최대열방출률과 화재성장률 등을 제시하였다.

주거공간 가연물의 화재하중 산정방법의 비교연구 (Comparative Study on the Estimation Method of Fire Load for Residential Combustibles)

  • 최수영;김정용;남동군;김성찬
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.38-43
    • /
    • 2013
  • 본 연구는 주거공간 내 가연물의 화재하중 산정방법의 신뢰성을 평가하기 위한 연구로서 가연물의 3차원 형상정보를 통해 체적을 산정하고 문헌조사와 시편실험을 통해 얻은 가연물의 물성을 적용하여 화재하중을 산정한다. 대상 가연물은 주방 싱크대, 가정용 소파, 책상 세트이며 실화재 실험을 통해 가연물에서 방출되는 총열방출량을 측정하였다. 실화재 실험에서 측정된 총열방출량을 기준으로 문헌조사에 기초하여 계산된 화재하중은 6~120% 정도의 상대오차를 보였으나 시편실험에 기초한 화재하중은 20% 이내로 나타났다. 본 연구는 화재하중 평가의 오차가 형상정보뿐만 아니라 가연물의 재료 물성에 큰 영향을 받는다는 사실을 보여주고 있으며 이러한 연구를 통해 화재하중 산정기법을 향상시키는데 기여할 수 있다.

웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구 (Study on Fire Resistance of H-Section Beams Filled with Concrete at Web)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.76-84
    • /
    • 2011
  • 건축물 화재는 인명과 재산피해가 동시에 유발될 수 있는 인위 재해이며, 피해의 최소화하기 위해서는 건축물 설계단계부터 화재안전에 관한 요구사항 특히 내화성능을 충족해야만 한다. 강구조물에서의 보부재는 수평하중 전달과 바닥하중을 축부재로 전달하는 주요 구조부재이며, 주로 H형강으로 시공되고 있다. H형강의 내화성능은 내화피복 시공에 의해서 만족되고 있으나, 구조성능과 내화성능을 동시에 향상시킬 수 있는 콘크리트 충전 보부재의 내화성능에 관한 연구 그리고 작용 하중비에 따른 내화성능 연구는 미진한 실정이다. 따라서 본 논문에서는 H형강 보부재와 H형강 웨브에 보통강도 및 고강도 콘크리트가 충전된 H형강 보부재를 대상으로 내화성능과 하중비에 따른 한계온도 자료를 확보하여 향후 성능적 내화설계의 기초자료로 활용하고자 한다.

CFT 기둥의 축력비 및 압축강도 변화에 따른 화재거동 영향인자에 관한 실험적 연구 (An Experimental Study on the Fire Resistance effect on load ratio and compressive strength of the CFT Column under loading in fire)

  • 조경숙;김흥열;김형준;권인규;박경훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.371-376
    • /
    • 2010
  • The strength of steel material in a concrete filled steel tube (CFT) is reduced in fire, but the filled interior concrete structurally ensures the fire resistance due to its high thermal capacity. More, the contractibility of CFT is excellent since it can be constructed without form work. This research analyzed the interior concrete strength and deformation characteristics, which are the influence factors of the fire resistance of CFT, in proportion to the axial load ratio. The fire resistance performance according to changes of the axial load ratio showed great fluctuation. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the 24 MPa concrete exhibited the fire resistance time as 27, 113, and 180 minutes for the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance time were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of 40 MPa concrete showed the much lower fire resistance performance when comparing with those of 24 MPa concrete. The fire resistance performance was not increased significantly when the axial load ratio was reduced. Therefore, the deceased fire resistance performance of high strength concrete is assumed to be caused by the internal pressure increase upon the heat application.

  • PDF

철도 차량 화재시 화재강도 예측을 위한 연구 (A Study on the Prediction of Fire Load in case of a Train Fire)

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2101-2108
    • /
    • 2008
  • Most of train fires which occur in usual cases do not grow up significantly on a large scale enough to bring about casualties and harmful damages. However, the consequence of some train fire accidents can be devastating disaster so that it would be even recorded in history in unusual cases. Accordingly, such a probability of fire disaster cannot be ignored in aspect of the railway safety assesment. A scale of injury and damage is very difficult to predict and analyze. Because it is depend on various factors, i.e. fire load, burning period, facilities, environment condition, and so on. Thus, a prediction of fire load could be understood as a one methodology to estimate railway safety assesment. The summation method which is one of them is used to evaluate the overall fire load by assuming that sum of heat release rate per unit area or mass of each composite material equals the total. However, since the train fire is classified into a compartment fire in under-ventilation condition. The summation method do not estimate a fire load completely. In this journal, Various methods to predict fire load are introduced and evaluated. Especially the fire simulation tool FDS(Fire Dynamics Simulator)which is based on the CFD(Computational Fluid Dynamics) is introduced, too. Through the FDS simulation, numerical analyses for the fire load and flame spread are performed. Then, these results of the simulation are validated through the comparison study with the experimental data. Then, limitations and approximations including in simulation process are discussed. The future direction of research is proposed.

  • PDF

서점의 적재가연물의 연소특성에 관한 실험적 연구 (Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.47-53
    • /
    • 2011
  • 건축물 적재가연물은 종류 및 양 등의 특성에 따라 화재지속시간과 화재규모 등에 크게 기여한다. 서점은 다른 건축용도보다 가연물이 다량 적재되어 있으므로 화재발생시 화재위험성이 클 가능성이 있다. 그러나 한편으로는 서점 내부의 서적은 연소하면 탄화층이 형성되고 적재가연물량에 비해 노출표면적이 작기 때문에 화재시 열분해가스의 생성이 작을 가능성도 있다. 이러한 가능성을 다양한 실험을 통해 파악하여 서점의 화재안전설계에 합리적으로 반영할 필요가 있다. 따라서 본 연구에서는 서점의 성능위주설계에 활용하기 위하여 적재가연물을 재현한 시험체를 가열로에 넣고 ISO834-1:1999 표준가열곡선에 따라 가열하는 일련의 실험을 실행하였다. 이 실험 결과를 바탕으로 서점의 적재가연물의 연소발열성상을 파악하고 성능위주설계에 필요한 연소속도 및 열방출률 등을 제시하였다.

STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.